Literature DB >> 22285232

Effect of femoral component design on patellofemoral crepitance and patella clunk syndrome after posterior-stabilized total knee arthroplasty.

Benjamin M Frye1, Mark W Floyd, Dahn C Pham, John J Feldman, Brian R Hamlin.   

Abstract

The purpose of this study was to determine if recent changes to the femoral component of a particular posterior-stabilized total knee prosthesis would affect the incidence of postoperative patellofemoral crepitance and patella clunk syndrome. One hundred eight total knee arthroplasties were performed with the conventional design; 136 were performed after the femoral component was changed. Complications were compared between the groups with an average follow-up of 17.7 months and 12.4 months, respectively. Thirteen knees with the conventional design (12%) were found to have patellofemoral complications; no complications were noted with the new design (P < .0001). Femoral components with a deep trochlear groove and smooth transition of the intercondylar box appear to better accommodate any peripatellar fibrous nodule that may form after total knee arthroplasty.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22285232     DOI: 10.1016/j.arth.2011.12.009

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  Painful patellar clunk or crepitation of contemporary knee prostheses.

Authors:  Won Chul Choi; Keun-Jung Ryu; Sahnghoon Lee; Sang Cheol Seong; Myung Chul Lee
Journal:  Clin Orthop Relat Res       Date:  2013-05       Impact factor: 4.176

2.  Patello-femoral clunk syndrome-current concepts.

Authors:  Patinharayil Gopinathan
Journal:  J Orthop       Date:  2014-06-11

3.  Comparison of patellofemoral outcomes after TKA using two prostheses with different patellofemoral design features.

Authors:  Dae Kyung Bae; Jong Hun Baek; Kyung Tack Yoon; Hyuck Sung Son; Sang Jun Song
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-10       Impact factor: 4.342

4.  Does patellofemoral geometry in TKA affect patellar position in mid-flexion?

Authors:  Mo Saffarini; Stefano Zaffagnini; Simone Bignozzi; Francesca Colle; Maurilio Marcacci; David Dejour
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-03-13       Impact factor: 4.342

5.  Management of Painful Patellar Clunk and Crepitance: Results at a Mean Follow-Up of Five Years.

Authors:  J J Gholson; Devon D Goetz; Robert W Westermann; John Hart; John J Callaghan
Journal:  Iowa Orthop J       Date:  2017

Review 6.  Anterior knee pain following primary total knee arthroplasty.

Authors:  David Shervin; Katelyn Pratt; Travis Healey; Samantha Nguyen; William M Mihalko; Mouhanad M El-Othmani; Khaled J Saleh
Journal:  World J Orthop       Date:  2015-11-18

Review 7.  Patellofemoral crepitus after total knee arthroplasty: etiology and preventive measures.

Authors:  David N Conrad; Douglas A Dennis
Journal:  Clin Orthop Surg       Date:  2014-02-14

8.  Resurfacing versus not-resurfacing the patella in one-stage bilateral total knee arthroplasty: a prospective randomized clinical trial.

Authors:  Chengzhi Ha; Baoxin Wang; Wei Li; Kang Sun; Dawei Wang; Qicai Li
Journal:  Int Orthop       Date:  2019-06-21       Impact factor: 3.075

9.  Patellar Clunk Syndrome Following Posterior Stabilized Total Knee Replacement: Report of Two Cases.

Authors:  Ali H Chamseddine; Ibrahim Haidar; Mohammad Jawad Rahal; Ali Asfour; Mohammad O Boushnak
Journal:  Cureus       Date:  2020-11-11

10.  Post-cam clunk syndrome after posterior stabilized total knee arthroplasty as a sign of early femoral component loosening.

Authors:  Akihiko Toda; Katsumasa Tei; Tomoyuki Matsumoto; Kazunari Ishida; Hiroshi Sasaki; Kazuki Kodato; Yuichiro Nishizawa; Shinsuke Kirizuki; Nao Shibanuma; Hiroomi Tateishi; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Asia Pac J Sports Med Arthrosc Rehabil Technol       Date:  2017-12-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.