Modeling and experimentation of bone drilling forces.

JuEun Lee1, B Arda Gozen, O Burak Ozdoganlar.   

Abstract

Prediction and control of bone drilling forces are critical to the success of many orthopaedic operations. Uncontrolled and large forces can cause drill-bit breakage, drill breakthrough, excessive heat generation, and mechanical damage to the bone. This paper presents a mechanistic model for prediction of thrust forces and torques experienced during bone drilling. The model incorporates the radially varying drill-bit geometry and cutting conditions analytically, while capturing the material and friction properties empirically through a specific energy formulation. The forces from the chisel edge are modeled by considering the indentation process that occurs in the vicinity of the drill-bit axis. A procedure is outlined to calibrate the specific energies, where only a small number of calibration experiments are required for a wide range of drilling conditions and drill-bit geometry. The calibration parameters for the cortical portions of bovine tibia are identified through drilling tests. Subsequently, a series of validation tests are conducted under different feed rates and spindle speeds. The thrust forces and torques were observed to vary considerably between bones from different animals. The forces from the model were seen to match well with those from the experimentation within the inherent variations from the bone characteristics. The model can be used to select favorable drilling conditions, to assist in robotic surgeries, and to design optimal orthopaedic drill bits. Copyright Â
© 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22281407     DOI: 10.1016/j.jbiomech.2011.12.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  An experimental evaluation of loads occurring during guided drilling for cochlear implantation.

Authors:  Jan-Philipp Kobler; Sergej Wall; G Jakob Lexow; Carl Philipp Lang; Omid Majdani; Lüder A Kahrs; Tobias Ortmaier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-02-12       Impact factor: 2.924

2.  Optimization of multiple quality characteristics in bone drilling using grey relational analysis.

Authors:  Rupesh Kumar Pandey; Sudhansu Sekhar Panda
Journal:  J Orthop       Date:  2014-07-17

3.  A predictive bone drilling force model for haptic rendering with experimental validation using fresh cadaveric bone.

Authors:  Yanping Lin; Huajiang Chen; Dedong Yu; Ying Zhang; Wen Yuan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-22       Impact factor: 2.924

4.  Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: an Animal in Vitro Study.

Authors:  Mohammad Javad Ein-Afshar; Mostafa Shahrezaee; Mohammad Hossein Shahrezaee; Seyed Reza Sharifzadeh
Journal:  Arch Bone Jt Surg       Date:  2020-09

5.  Comparative Study of Different Drills for Bone Drilling: A Systematic Approach.

Authors:  O Pazarci; Y Torun; A Ozturk; Z Oztemur
Journal:  Malays Orthop J       Date:  2020-07

6.  Comparative Analysis of Cutting Forces, Torques, and Vibration in Drilling of Bovine, Porcine, and Artificial Femur Bone with Considerations for Robot Effector Stiffness.

Authors:  Oluseyi Adewale Orelaja; Xingsong Wang; Donghua Shen; Dauda Sh Ibrahim; Tianzheng Zhao; Umer Sharif; Ishola A Afiz
Journal:  J Healthc Eng       Date:  2020-10-19       Impact factor: 2.682

7.  The effects of multiple drilling of a bone with the same drill bit: thermal and force analysis.

Authors:  Jean Gustave Tsiagadigui; Benoit Ndiwe; Marie-Ange Ngo Yamben; Nzogning Fotio; Fabrice Ella Belinga; Ebenezer Njeugna
Journal:  Heliyon       Date:  2022-02-10

8.  Infrared Thermographic Evaluation of Temperature Modifications Induced during Implant Site Preparation with Steel vs. Zirconia Implant Drill.

Authors:  Antonio Scarano; Felice Lorusso; Sammy Noumbissi
Journal:  J Clin Med       Date:  2020-01-05       Impact factor: 4.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.