Literature DB >> 22280950

Prevalence and mechanism of tricuspid regurgitation following implantation of endocardial leads for pacemaker or cardioverter-defibrillator.

Maha A Al-Mohaissen1, Kwan Leung Chan.   

Abstract

Endocardial lead-induced tricuspid regurgitation has not been well recognized, either clinically or echocardiographically, and yet it is likely a preventable iatrogenic disease. In severe cases, it can lead to right ventricular failure and require tricuspid valve surgery. This complication will become increasingly important, because the numbers of permanent pacemakers and implantable cardioverter-defibrillators are expected to increase because of the aging population and the expanding capabilities of these devices. Published studies are largely retrospective, and serial studies to assess the time course of the development of tricuspid regurgitation are lacking. The mechanisms and severity of tricuspid regurgitation may not be well evaluated by two-dimensional echocardiography. Real-time three-dimensional echocardiography appears to be a promising technique to evaluate the mechanism of tricuspid regurgitation and may allow the early detection of patients who will develop severe lead-induced tricuspid regurgitation. A better understanding of the mechanism of lead-induced tricuspid regurgitation will be essential to the development of preventive strategies, which can then be tested in future clinical trials. Copyright Â
© 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22280950     DOI: 10.1016/j.echo.2011.11.020

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  20 in total

1.  Tricuspid Regurgitation: 2015 Reflections and Re-evaluation.

Authors:  Julia Grapsa; Lawrence Rudski
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-10

Review 2.  Tricuspid valve incompetence following implantation of ventricular leads.

Authors:  Giselle A Baquero; Jerry Luck; Gerald V Naccarelli; Mario D Gonzalez; Javier E Banchs
Journal:  Curr Heart Fail Rep       Date:  2015-04

3.  Impact of implantable transvenous device lead location on severity of tricuspid regurgitation.

Authors:  Karima Addetia; Francesco Maffessanti; Anuj Mediratta; Megan Yamat; Lynn Weinert; Joshua D Moss; Hemal M Nayak; Martin C Burke; Amit R Patel; Eric Kruse; Valluvan Jeevanandam; Victor Mor-Avi; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2014-08-14       Impact factor: 5.251

4.  Comprehensive Right-Sided Assessment for Transcatheter Aortic Valve Replacement Risk Stratification: Time for a Change.

Authors:  João L Cavalcante; Marc A Simon; Stephen Y Chan
Journal:  J Am Soc Echocardiogr       Date:  2017-01       Impact factor: 5.251

5.  Pacemaker-induced tricuspid regurgitation is uncommon immediately post-implantation.

Authors:  Daniel P Rothschild; James A Goldstein; Nathan Kerner; Amr E Abbas; Meet Patel; Wai Shun Wong
Journal:  J Interv Card Electrophysiol       Date:  2017-07-06       Impact factor: 1.900

6.  Comparison of Tricuspid Regurgitation Severity Between Cardiac Resynchronization Therapy Versus Right Ventricular Pacing in Patients With Chronic Obstructive Pulmonary Disease.

Authors:  James Livesay; Benjamin Fogelson; Hassan Tahir; Raj Baljepally
Journal:  Cardiol Res       Date:  2022-06-16

7.  The role of cardiac surgery in transvenous lead extraction. A high-volume center experience with 3207 procedures.

Authors:  Łukasz Tułecki; Marek Czajkowski; Sylwia Targońska; Konrad Tomków; Dorota Nowosielecka; Wojciech Jacheć; Anna Polewczyk; Andrzej Kutarski
Journal:  Kardiochir Torakochirurgia Pol       Date:  2022-10-08

Review 8.  Electrical Stimulation for Low-Energy Termination of Cardiac Arrhythmias: a Review.

Authors:  Skylar Buchan; Ronit Kar; Mathews John; Allison Post; Mehdi Razavi
Journal:  Cardiovasc Drugs Ther       Date:  2021-08-07       Impact factor: 3.727

Review 9.  Tricuspid regurgitation following implantation of a pacemaker/cardioverter-defibrillator.

Authors:  Maha A Al-Mohaissen; Kwan Leung Chan
Journal:  Curr Cardiol Rep       Date:  2013-05       Impact factor: 2.931

Review 10.  Assessment of right ventricular function in left ventricular assist device candidates.

Authors:  Salim Hayek; Daniel B Sims; David W Markham; Javed Butler; Andreas P Kalogeropoulos
Journal:  Circ Cardiovasc Imaging       Date:  2014-03       Impact factor: 7.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.