Literature DB >> 22279119

Platelet reduction after stentless pericardial aortic valve replacement.

Alberto Repossini1, Daniel Bloch, Claudio Muneretto, Paolo Piccoli, Gianluigi Bisleri, Sven Beholz.   

Abstract

The aim of the study was to investigate the multi-factorial phenomenon of possible postoperative thrombocytopenia after aortic valve replacement (AVR) with the freedom SOLO (FS) bioprosthesis. A total of 254 patients underwent AVR with FS bioprosthesis in two cardiac surgery institutes. Platelet counts were measured preoperatively, immediately postoperatively and daily until the 11th day postoperatively. A multivariate generalized estimating equation model was applied to identify prognostic factors for whether or not patients postoperative platelet counts indicated no thrombocytopenia (platelet count >150 10(3)/mm(3)) versus at least mild thrombocytopenia (≤150 10(3)/mm(3)). Preoperatively, 11.2% of patients showed thrombocytopenia. The preoperative platelet count averaged 233.0 ± 83.2 10(3)/mm(3). The postoperative mean of platelet counts decreased daily reaching a minimum mean of 88.4 ± 58.8 10(3)/mm(3) 3 days after surgery and then started to increase, with the Day 11 postoperative mean of 173.3 ± 51.8 10(3)/mm(3). Compared with patients with no preoperative thrombocytopenia, patients with preoperative thrombocytopenia had an 8.69 increased odds of being in the group with postoperative platelet count <150 10(3)/mm(3). No major haemorrhagic or thromboembolic event was reported during hospitalization. This study shows that thrombocytopenia after the FS bioprosthesis replacement is a transient postoperative phenomenon, largely resolved within a few days after surgery, with no clinical consequences and haemodynamic dysfunction.

Entities:  

Mesh:

Year:  2012        PMID: 22279119      PMCID: PMC3309805          DOI: 10.1093/icvts/ivr069

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  13 in total

Review 1.  Recommendations for the implantation of the Pericarbon Freedom stentless valve.

Authors:  Sven Beholz; Steven Hunter; Carlos A Infantes Alcón; Claudio Zussa
Journal:  Heart Surg Forum       Date:  2005       Impact factor: 0.676

2.  Operative technique and early hemodynamic results with the Freedom Solo valve.

Authors:  Sven Beholz; Benjamin Claus; Simon Dushe; Wolfgang Konertz
Journal:  J Heart Valve Dis       Date:  2006-05

3.  Detoxification process for glutaraldehyde-treated bovine pericardium: biological, chemical and mechanical characterization.

Authors:  C Stacchino; G Bona; F Bonetti; S Rinaldi; L Della Ciana; A Grignani
Journal:  J Heart Valve Dis       Date:  1998-03

4.  The Cryolife-O'Brien composite aortic stentless xenograft: surgical technique of implantation.

Authors:  M F O'Brien
Journal:  Ann Thorac Surg       Date:  1995-08       Impact factor: 4.330

5.  Single-suture line placement of a pericardial stentless valve.

Authors:  Alberto Repossini; Igor Kotelnikov; Riad Bouchikhi; Tiziano Torre; Bruno Passaretti; Oberdan Parodi; Vincenzo Arena
Journal:  J Thorac Cardiovasc Surg       Date:  2005-11       Impact factor: 5.209

Review 6.  Thrombocytopenia in cardiovascular patients: diagnosis and management.

Authors:  William H Matthai
Journal:  Chest       Date:  2005-02       Impact factor: 9.410

7.  The Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement.

Authors:  Sven Beholz; Simon Dushe; Wolfgang Konertz
Journal:  J Heart Valve Dis       Date:  2007-01

8.  Age-dependent depression in circulating endothelial progenitor cells in patients undergoing coronary artery bypass grafting.

Authors:  Robert J Scheubel; Holger Zorn; Rolf-Edgar Silber; Oliver Kuss; Henning Morawietz; Juergen Holtz; Andreas Simm
Journal:  J Am Coll Cardiol       Date:  2003-12-17       Impact factor: 24.094

9.  Aortic valve replacement with the Sorin Pericarbon Freedom stentless prosthesis: 7 years' experience in 130 patients.

Authors:  Augusto D'Onofrio; Stefano Auriemma; Paolo Magagna; Alessandro Favaro; Antonio Cannarella; Caterina Piccin; Massimo Bilotta; Nicola Abbiate; Nicola Lamascese; Alessandro Fabbri
Journal:  J Thorac Cardiovasc Surg       Date:  2007-08       Impact factor: 5.209

10.  Differences in the recovery of platelet counts after biological aortic valve replacement.

Authors:  Lutz Hilker; Michael Wodny; Mario Ginesta; Hans-Georg Wollert; Lothar Eckel
Journal:  Interact Cardiovasc Thorac Surg       Date:  2008-10-08
View more
  4 in total

1.  eComment. platelet transfusion after aortic valve replacement by the Freedom Solo bioprosthesis.

Authors:  Jamil Hajj-Chahine
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-04

2.  Thrombocytopenia in Moderate- to High-Risk Sutureless Aortic Valve Replacement.

Authors:  Puwadon Thitivaraporn; Sarun Chiramongkol; Dittapol Muntham; Nopporn Pornpatrtanarak; Chanapong Kittayarak; Jule Namchaisiri; Seri Singhatanadgige; Pat Ongcharit; Vichai Benjacholamas
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2018-06-05

3.  An overlooked fact: thrombocytopenia following bioprosthetic aortic valve replacement.

Authors:  Mehmet Kizilay; Ferruh Elbir; Ahmet Arif Aglar; Unsal Vural; Ahmet Yavuz Balci; İbrahim Yekeler
Journal:  Kardiochir Torakochirurgia Pol       Date:  2019-04-04

4.  Platelet-to-Lymphocyte Ratio May Predict the Severity of Calcific Aortic Stenosis.

Authors:  Serkan Akdag; Aytac Akyol; Muntecep Asker; Ramazan Duz; Hasan Ali Gumrukcuoglu
Journal:  Med Sci Monit       Date:  2015-11-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.