Literature DB >> 18842699

Differences in the recovery of platelet counts after biological aortic valve replacement.

Lutz Hilker1, Michael Wodny, Mario Ginesta, Hans-Georg Wollert, Lothar Eckel.   

Abstract

Observations among Karlsburg patients in 2006 revealed that the majority of very low platelet levels inducing postoperative heparin-induced-thrombocytopenia (HIT)-diagnostics with at the end negative results appeared related to aortic valve replacement (AVR) with stentless bioprostheses. We compared the postoperative courses of platelet counts in patients having had AVR with stentless prostheses (Sorin Biomedica Freedom Solo [SOLO]) or stented prostheses (Carpentier Edwards Perimount [PM]). Between February 2005 and April 2007, 209 patients received AVR with SOLO, in 137 patients a PM-prosthesis was implanted. The mean platelet levels were compared from the first up to the fifth postoperative day. A higher occurrence of platelet levels below 100 Gpt/l between the second and the fifth postoperative day was found in the SOLO-group (71.9%) compared with the other biological substitute PM (36.6%). Differences in platelet counts between SOLO- and PM-subgroups were measured for day 2 (P=0.03), day 3 (P=0.0004) day 4 (P=0.0007), day 5 (P=0.0002) and at discharge (P<0.0001). Following intervention with conventional biological AVR, differences in the postoperative recovery of platelet counts can be detected, depending on the prosthesis used. The causes for and the clinical implications of this phenomenon are not yet assessed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18842699     DOI: 10.1510/icvts.2008.188524

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  7 in total

1.  eComment. platelet transfusion after aortic valve replacement by the Freedom Solo bioprosthesis.

Authors:  Jamil Hajj-Chahine
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-04

2.  Platelet reduction after stentless pericardial aortic valve replacement.

Authors:  Alberto Repossini; Daniel Bloch; Claudio Muneretto; Paolo Piccoli; Gianluigi Bisleri; Sven Beholz
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-01-24

3.  Evaluation of platelet count after isolated biological aortic valve replacement with Freedom Solo bioprosthesis.

Authors:  Antonio Miceli; Daniyar Gilmanov; Michele Murzi; Maria S Parri; Alfredo G Cerillo; Stefano Bevilacqua; Pier A Farneti; Mattia Glauber
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

4.  An overlooked fact: thrombocytopenia following bioprosthetic aortic valve replacement.

Authors:  Mehmet Kizilay; Ferruh Elbir; Ahmet Arif Aglar; Unsal Vural; Ahmet Yavuz Balci; İbrahim Yekeler
Journal:  Kardiochir Torakochirurgia Pol       Date:  2019-04-04

Review 5.  Quantitative and Qualitative Platelet Derangements in Cardiac Surgery and Extracorporeal Life Support.

Authors:  Enrico Squiccimarro; Federica Jiritano; Giuseppe Filiberto Serraino; Hugo Ten Cate; Domenico Paparella; Roberto Lorusso
Journal:  J Clin Med       Date:  2021-02-06       Impact factor: 4.241

6.  Thrombocytopenia After Aortic Valve Replacement: Comparison Between Sutureless Perceval S Valve and Perimount Magna Ease Bioprosthesis.

Authors:  Syed Saleem Mujtaba; Simon Ledingham; Asif Raza Shah; Stephan Schueler; Stephen Clark; Thasee Pillay
Journal:  Braz J Cardiovasc Surg       Date:  2018 Mar-Apr

7.  Comparison of Postoperative Outcomes of Sutureless versus Stented Bioprosthetic Aortic Valve Replacement.

Authors:  Yesim Guner; Ayse Çiçek; Mehmet Karacalilar; Burak Ersoy; Mugisha Kyaruzi; Burak Onan
Journal:  Braz J Cardiovasc Surg       Date:  2022-05-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.