Literature DB >> 22277307

Developing an efficient and reliable dry powder inhaler for pulmonary drug delivery--a review for multidisciplinary researchers.

Nazrul Islam1, Matthew J Cleary.   

Abstract

Pulmonary drug delivery is the focus of much research and development because of its great potential to produce maximum therapeutic benefit. Among the available options the dry powder inhaler (DPI) is the preferred device for the treatment of an increasingly diverse number of diseases. However, as drug delivery from a DPI involves a complicated set of physical processes and the integration of drug formulations, device design and patient usage, the engineering development of this medical technology is proving to be a great challenge. Currently there is large range of devices that are either available on the market or under development, however, none exhibit superior clinical efficacy. A major concern is the inter- and intra-patient variability of the drug dosage delivered to the deep lungs. The extent of variability depends on the drug formulation, the device design and the patient's inhalation profile. This article reviews recent advances in DPI technology and presents the key factors which motivate and constrain the successful engineering of a universal, patient-independent DPI that is capable of efficient, reliable and repeatable drug delivery. A strong emphasis is placed on the physical processes of drug powder aerosolisation, deagglomeration, and dispersion and on the engineering of formulations and inhalers that can optimise these processes.
Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22277307     DOI: 10.1016/j.medengphy.2011.12.025

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  27 in total

Review 1.  Devices for dry powder drug delivery to the lung.

Authors:  Kai Berkenfeld; Alf Lamprecht; Jason T McConville
Journal:  AAPS PharmSciTech       Date:  2015-05-12       Impact factor: 3.246

2.  Engineered mannitol ternary additives improve dispersion of lactose-salbutamol sulphate dry powder inhalations.

Authors:  Waseem Kaialy; Ali Nokhodchi
Journal:  AAPS J       Date:  2013-04-17       Impact factor: 4.009

3.  Development of high efficiency ventilation bag actuated dry powder inhalers.

Authors:  Srinivas R B Behara; P Worth Longest; Dale R Farkas; Michael Hindle
Journal:  Int J Pharm       Date:  2014-02-07       Impact factor: 5.875

4.  Efficient Nose-to-Lung (N2L) Aerosol Delivery with a Dry Powder Inhaler.

Authors:  P Worth Longest; Laleh Golshahi; Srinivas R B Behara; Geng Tian; Dale R Farkas; Michael Hindle
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2014-09-05       Impact factor: 2.849

5.  Development of a New Inhaler for High-Efficiency Dispersion of Spray-Dried Powders Using Computational Fluid Dynamics (CFD) Modeling.

Authors:  Worth Longest; Dale Farkas
Journal:  AAPS J       Date:  2019-02-07       Impact factor: 4.009

6.  The Effect of Spacer Morphology on the Aerosolization Performance of Metered-Dose Inhalers.

Authors:  Sepideh Momeni; Ali Nokhodchi; Saeed Ghanbarzadeh; Hamed Hamishehkar
Journal:  Adv Pharm Bull       Date:  2016-06-30

7.  Characterization of a New High-Dose Dry Powder Inhaler (DPI) Based on a Fluidized Bed Design.

Authors:  Dale R Farkas; Michael Hindle; P Worth Longest
Journal:  Ann Biomed Eng       Date:  2015-05-19       Impact factor: 3.934

8.  Aerodynamic factors responsible for the deaggregation of carrier-free drug powders to form micrometer and submicrometer aerosols.

Authors:  P Worth Longest; Yoen-Ju Son; Landon Holbrook; Michael Hindle
Journal:  Pharm Res       Date:  2013-03-08       Impact factor: 4.200

9.  Evaluation and modification of commercial dry powder inhalers for the aerosolization of a submicrometer excipient enhanced growth (EEG) formulation.

Authors:  Yoen-Ju Son; P Worth Longest; Geng Tian; Michael Hindle
Journal:  Eur J Pharm Sci       Date:  2013-04-19       Impact factor: 4.384

10.  Development of characteristic upper tracheobronchial airway models for testing pharmaceutical aerosol delivery.

Authors:  Ross L Walenga; Geng Tian; P Worth Longest
Journal:  J Biomech Eng       Date:  2013-09       Impact factor: 2.097