Literature DB >> 22277053

Magnetic resonance imaging metallic artifact of commonly encountered surgical implants and foreign material.

James Sutherland-Smith1, Brenda Tilley.   

Abstract

Magnetic resonance imaging (MRI) artifacts secondary to metallic implants and foreign bodies are well described. Herein, we provide quantitative data from veterinary implants including total hip arthroplasty implants, cranial cruciate repair implants, surgical screws, a skin staple, ligation clips, an identification microchip, ameroid constrictor, and potential foreign bodies including air gun and BB projectiles and a sewing needle. The objects were scanned in a gelatin phantom with plastic grid using standardized T2-weighted turbo-spin echo (TSE), T1-weighted spin echo, and T2*-weighted gradient recalled echo (GRE) image acquisitions at 1.5 T. Maximum linear dimensions and areas of signal voiding and grid distortion were calculated using a DICOM workstation for each sequence and object. Artifact severity was similar between the T2-weighted TSE and T1-weighted images, while the T2*-weighted images were most susceptible to artifact. Metal type influenced artifact size with the largest artifacts arising from steel objects followed by surgical stainless steel, titanium, and lead. For animals with metallic surgical implants or foreign bodies, the quantification of the artifact size will help guide clinicians on the viability of MRI.
© 2012 Veterinary Radiology & Ultrasound.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22277053     DOI: 10.1111/j.1740-8261.2011.01916.x

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  4 in total

1.  Dural tear and myelomalacia caused by an airgun pellet in a cat.

Authors:  Cristian de la Fuente; Sergio Ródenas; Martí Pumarola; Sònia Añor
Journal:  Can Vet J       Date:  2013-07       Impact factor: 1.008

2.  Quantifying the effect of posterior spinal instrumentation on the MRI signal of adjacent intervertebral discs.

Authors:  Mary H Foltz; Robert M O'Leary; Diana Reader; Nicholas L Rudolph; Krista A Schlitter; Jutta Ellermann; Casey P Johnson; David W Polly; Arin M Ellingson
Journal:  Spine Deform       Date:  2020-05-24

3.  Comparison of MRI Visualization Following Minimally Invasive and Open TLIF: A Retrospective Single-Center Study.

Authors:  Vadim A Byvaltsev; Andrei A Kalinin; Morgan B Giers; Valerii V Shepelev; Yurii Ya Pestryakov; Mikhail Yu Biryuchkov
Journal:  Diagnostics (Basel)       Date:  2021-05-19

4.  Diagnostic performance of 3D-multi-Echo-data-image-combination (MEDIC) for evaluating SLAP lesions of the shoulder.

Authors:  Felix Wuennemann; Laurent Kintzelé; Felix Zeifang; Michael W Maier; Iris Burkholder; Marc-André Weber; Hans-Ulrich Kauczor; Christoph Rehnitz
Journal:  BMC Musculoskelet Disord       Date:  2019-12-12       Impact factor: 2.362