Literature DB >> 22274479

Efficient reduction of speckle noise in Optical Coherence Tomography.

Maciej Szkulmowski1, Iwona Gorczynska, Daniel Szlag, Marcin Sylwestrzak, Andrzej Kowalczyk, Maciej Wojtkowski.   

Abstract

Speckle pattern, which is inherent in coherence imaging, influences significantly axial and transversal resolution of Optical Coherence Tomography (OCT) instruments. The well known speckle removal techniques are either sensitive to sample motion, require sophisticated and expensive sample tracking systems, or involve sophisticated numerical procedures. As a result, their applicability to in vivo real-time imaging is limited. In this work, we propose to average multiple A-scans collected in a fully controlled way to reduce the speckle contrast. This procedure involves non-coherent averaging of OCT A-scans acquired from adjacent locations on the sample. The technique exploits scanning protocol with fast beam deflection in the direction perpendicular to lateral dimension of the cross-sectional image. Such scanning protocol reduces the time interval between A-scans to be averaged to the repetition time of the acquisition system. Consequently, the averaging algorithm is immune to bulk motion of an investigated sample, does not require any sophisticated data processing to align cross-sectional images, and allows for precise control of lateral shift of the scanning beam on the object. The technique is tested with standard Spectral OCT system with an extra resonant scanner used for rapid beam deflection in the lateral direction. Ultrahigh speed CMOS camera serves as a detector and acquires 200,000 spectra per second. A dedicated A-scan generation algorithm allows for real-time display of images with reduced speckle contrast at 6 frames/second. This technique is applied to in vivo imaging of anterior and posterior segments of the human eye and human skin.

Entities:  

Mesh:

Year:  2012        PMID: 22274479     DOI: 10.1364/OE.20.001337

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  41 in total

1.  Multimodal instrument for high-sensitivity autofluorescence and spectral optical coherence tomography of the human eye fundus.

Authors:  Katarzyna Komar; Patrycjusz Stremplewski; Marta Motoczyńska; Maciej Szkulmowski; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2013-10-29       Impact factor: 3.732

2.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

3.  Multi-penalty conditional random field approach to super-resolved reconstruction of optical coherence tomography images.

Authors:  Ameneh Boroomand; Alexander Wong; Edward Li; Daniel S Cho; Betty Ni; Kostandinka Bizheva
Journal:  Biomed Opt Express       Date:  2013-09-06       Impact factor: 3.732

4.  Aperture phase modulation with adaptive optics: a novel approach for speckle reduction and structure extraction in optical coherence tomography.

Authors:  Pengfei Zhang; Suman K Manna; Eric B Miller; Yifan Jian; Ratheesh K Meleppat; Marinko V Sarunic; Edward N Pugh; Robert J Zawadzki
Journal:  Biomed Opt Express       Date:  2019-01-15       Impact factor: 3.732

5.  High dynamic range optical coherence tomography angiography (HDR-OCTA).

Authors:  Xiang Wei; Tristan T Hormel; Shaohua Pi; Yukun Guo; Yifan Jian; Yali Jia
Journal:  Biomed Opt Express       Date:  2019-06-24       Impact factor: 3.732

6.  Improving visible light OCT of the human retina with rapid spectral shaping and axial tracking.

Authors:  Tingwei Zhang; Aaron M Kho; Vivek J Srinivasan
Journal:  Biomed Opt Express       Date:  2019-05-21       Impact factor: 3.732

7.  Cluster-based filtering framework for speckle reduction in OCT images.

Authors:  M Hossein Eybposh; Zahra Turani; Darius Mehregan; Mohammadreza Nasiriavanaki
Journal:  Biomed Opt Express       Date:  2018-11-19       Impact factor: 3.732

8.  Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited].

Authors:  Johannes F de Boer; Rainer Leitgeb; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2017-06-15       Impact factor: 3.732

9.  Pixel-based speckle adjustment for noise reduction in Fourier-domain OCT images.

Authors:  Anqi Zhang; Jiefeng Xi; Jitao Sun; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-02-21       Impact factor: 3.732

Review 10.  Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited].

Authors:  Michael Pircher; Robert J Zawadzki
Journal:  Biomed Opt Express       Date:  2017-04-19       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.