Literature DB >> 22270788

Accuracy and reliability of length measurements on three-dimensional computed tomography using open-source OsiriX software.

Gihyeon Kim1, Ho-Joong Jung, Han-Jun Lee, Jae-Sung Lee, Seungbum Koo, Seung-Hwan Chang.   

Abstract

There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal portion of femur. The lengths between tunnel orifices were measured using Mitutoyo Digimatic digital calipers to establish the gold standard, and with the OsiriX program in 3D multi-planar reformatting mode for comparison. All measurements were recorded by a principal (replicate 1, trial 1) and a secondary observer (replicate 2, trial 1) and were repeated once by each observer (trial 2). The mean differences between OsiriX and real measurements were less than 0.1 mm in both replicates, and maximum differences were less than 0.3 mm. There were no significant differences between the replicates and real measurements (p=0.544 and 0.622 for replicates 1 and 2, respectively). The intraclass correlation coefficients (ICC) were very high between trials and between replicates (ICC=0.998 and 0.999, respectively). For kinematic analysis of the knees, length measurements on 3D-CT using OsiriX program can be used as alternatives to real measurements with less than 0.3-mm accuracy and very high reliability.

Entities:  

Mesh:

Year:  2012        PMID: 22270788      PMCID: PMC3389091          DOI: 10.1007/s10278-012-9458-6

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  22 in total

1.  Nonanatomic tunnel position in traditional transtibial single-bundle anterior cruciate ligament reconstruction evaluated by three-dimensional computed tomography.

Authors:  Sebastian Kopf; Brian Forsythe; Andrew K Wong; Scott Tashman; William Anderst; James J Irrgang; Freddie H Fu
Journal:  J Bone Joint Surg Am       Date:  2010-06       Impact factor: 5.284

2.  The location of femoral and tibial tunnels in anatomic double-bundle anterior cruciate ligament reconstruction analyzed by three-dimensional computed tomography models.

Authors:  Brian Forsythe; Sebastian Kopf; Andrew K Wong; Cesar A Q Martins; William Anderst; Scott Tashman; Freddie H Fu
Journal:  J Bone Joint Surg Am       Date:  2010-06       Impact factor: 5.284

3.  G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences.

Authors:  Franz Faul; Edgar Erdfelder; Albert-Georg Lang; Axel Buchner
Journal:  Behav Res Methods       Date:  2007-05

4.  Demonstration of the Adamkiewicz artery by multidetector computed tomography angiography analysed with the open-source software OsiriX.

Authors:  G Melissano; L Bertoglio; V Civelli; A C Moraes Amato; G Coppi; E Civilini; G Calori; F De Cobelli; A Del Maschio; R Chiesa
Journal:  Eur J Vasc Endovasc Surg       Date:  2009-02-20       Impact factor: 7.069

5.  Computed tomography evaluation of the femoral and tibial attachments of the posterior cruciate ligament in vitro.

Authors:  Philippe Greiner; Robert A Magnussen; Sébastien Lustig; Guillaume Demey; Philippe Neyret; Elvire Servien
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-09       Impact factor: 4.342

6.  Effects of postmortem storage by freezing on ligament tensile behavior.

Authors:  S L Woo; C A Orlando; J F Camp; W H Akeson
Journal:  J Biomech       Date:  1986       Impact factor: 2.712

Review 7.  OsiriX: an open-source software for navigating in multidimensional DICOM images.

Authors:  Antoine Rosset; Luca Spadola; Osman Ratib
Journal:  J Digit Imaging       Date:  2004-06-29       Impact factor: 4.056

8.  General consumer communication tools for improved image management and communication in medicine.

Authors:  Chantal Rosset; Antoine Rosset; Osman Ratib
Journal:  J Digit Imaging       Date:  2005-12       Impact factor: 4.056

9.  Virtual CO2 MDCT pancreatography: a new feasible technique for minimally invasive pancreatectomy in intraductal papillary mucinous neoplasms.

Authors:  Maki Sugimoto; Hideki Yasuda; Keiji Koda; Masato Suzuki; Masato Yamazaki; Tohru Tezuka; Chihiro Kosugi; Ryota Higuchi; Tomohiro Takenoue; Shiho Yamamoto; Yoshihisa Watayo; Yosuke Yagawa; Tomonori Tsuchiya
Journal:  Hepatogastroenterology       Date:  2008 Jan-Feb

10.  Assessment of correlation between knee notch width index and the three-dimensional notch volume.

Authors:  Carola F van Eck; Cesar A Q Martins; Stephan G F Lorenz; Freddie H Fu; P Smolinski
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-04-08       Impact factor: 4.342

View more
  30 in total

1.  The isometry of two different paths for remnant-preserving posterior cruciate ligament reconstruction.

Authors:  Ho-Joong Jung; Jin Hong Kim; Han Jun Lee; Seungbum Koo; Seung-Hwan Chang; Young Bok Jung; Sang Hak Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-07-05       Impact factor: 4.342

2.  Comparison of femoral tunnel widening between outside-in and trans-tibial double-bundle ACL reconstruction.

Authors:  Yong Seuk Lee; Beom Koo Lee; Won Seok Oh; Yong Kyun Cho
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-13       Impact factor: 4.342

3.  The correlation between femoral sulcus morphology and osteoarthritic changes in the patello-femoral joint.

Authors:  Takanori Iriuchishima; Keinosuke Ryu; Tohru Murakami; Hiroshi Yorifuji
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-06-04       Impact factor: 4.342

4.  Optimizing working space in laparoscopy: CT-measurement of the effect of neuromuscular blockade and its reversal in a porcine model.

Authors:  John Vlot; Patricia A Specht; René M H Wijnen; Joost van Rosmalen; Egbert G Mik; Klaas M A Bax
Journal:  Surg Endosc       Date:  2014-11-01       Impact factor: 4.584

5.  Accuracy of linear measurements around dental implants by means of cone beam computed tomography with different exposure parameters.

Authors:  Lauren O L Bohner; Pedro Tortamano; Juliana Marotti
Journal:  Dentomaxillofac Radiol       Date:  2017-03-23       Impact factor: 2.419

6.  Volume reduction of cystic lesions after surgical decompression: a computerised three-dimensional computed tomographic evaluation.

Authors:  Giuseppe Lizio; Anna Freni Sterrantino; Sara Ragazzini; Claudio Marchetti
Journal:  Clin Oral Investig       Date:  2012-10-26       Impact factor: 3.573

7.  Sex prediction from the femur and hip bone using a sample of CT images from a Spanish population.

Authors:  Ana Clavero; Miquel Salicrú; Daniel Turbón
Journal:  Int J Legal Med       Date:  2014-10-01       Impact factor: 2.686

8.  Morphological and Volumetric Assessment of Cerebral Ventricular System with 3D Slicer Software.

Authors:  Miguel Gonzalo Domínguez; Cristina Hernández; Pablo Ruisoto; Juan A Juanes; Alberto Prats; Tomás Hernández
Journal:  J Med Syst       Date:  2016-05-05       Impact factor: 4.460

9.  Auditory Brainstem Implant Array Position Varies Widely Among Adult and Pediatric Patients and Is Associated With Perception.

Authors:  Samuel R Barber; Elliott D Kozin; Aaron K Remenschneider; Sidharth V Puram; Max Smith; Barbara S Herrmann; Mary E Cunnane; M Christian Brown; Daniel J Lee
Journal:  Ear Hear       Date:  2017 Nov/Dec       Impact factor: 3.570

10.  CT morphology and morphometry of the normal adult coccyx.

Authors:  Jason T K Woon; Vivekanandan Perumal; Jean-Yves Maigne; Mark D Stringer
Journal:  Eur Spine J       Date:  2012-11-29       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.