Literature DB >> 22263653

Comparison of the visual and intraocular optical performance of a refractive multifocal IOL with rotational asymmetry and an apodized diffractive multifocal IOL.

Jorge L Alió1, Ana B Plaza-Puche, Jaime Javaloy, María José Ayala.   

Abstract

PURPOSE: To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL.
METHODS: Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations.
RESULTS: Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02).
CONCLUSIONS: Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22263653     DOI: 10.3928/1081597X-20120110-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  15 in total

1.  Quality of vision, patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens.

Authors:  Emilio Pedrotti; Rodolfo Mastropasqua; Jacopo Bonetto; Christian Demasi; Francesco Aiello; Carlo Nucci; Cesare Mariotti; Giorgio Marchini
Journal:  Int Ophthalmol       Date:  2017-07-17       Impact factor: 2.031

2.  Perceived image quality with simulated segmented bifocal corrections.

Authors:  Carlos Dorronsoro; Aiswaryah Radhakrishnan; Pablo de Gracia; Lucie Sawides; Susana Marcos
Journal:  Biomed Opt Express       Date:  2016-10-03       Impact factor: 3.732

3.  Comparative analysis of the visual and refractive outcomes of a refractive segmented multifocal intraocular lens with and without toricity: 1-year results.

Authors:  Ryo Shodai; Kazuno Negishi; Hiroyuki Arai; Ikuko Toda; Hidemasa Torii; Kazuo Tsubota
Journal:  Jpn J Ophthalmol       Date:  2017-01-13       Impact factor: 2.447

4.  Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens.

Authors:  Jing Zhao; Liang-Ping Liu; Huan-Huan Cheng; Jian-Bing Li; Xiao-Tong Han; Yu Liu; Ming-Xing Wu
Journal:  Int J Ophthalmol       Date:  2020-09-18       Impact factor: 1.779

5.  Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

Authors:  M Ouchi; S Kinoshita
Journal:  Eye (Lond)       Date:  2015-03-06       Impact factor: 3.775

6.  Clinical outcomes with a new design in multifocal intraocular lens: a pilot study.

Authors:  Jorge L Alió; Pilar Yébana; Mario Cantó; Ana B Plaza; Alfredo Vega; Jorge L Alió Del Barrio; Francisco Lugo
Journal:  Eye Vis (Lond)       Date:  2020-07-18

7.  [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

Authors:  B C Thomas; G U Auffarth; R Philips; J Novák; J Blazek; H Adamkova; T M Rabsilber
Journal:  Ophthalmologe       Date:  2013-11       Impact factor: 1.059

8.  Visual Results Following Implantation of a Refractive Multifocal Intraocular Lens in One Eye and a Diffractive in the Contralateral Eye.

Authors:  Revan Yıldırım Karabağ; Üzeyir Günenç; Rukiye Aydın; Gül Arıkan; Hüseyin Aslankara
Journal:  Turk J Ophthalmol       Date:  2018-02-23

Review 9.  Correction of presbyopia: An integrated update for the practical surgeon.

Authors:  Marie Joan Therese D Balgos; Veronica Vargas; Jorge L Alió
Journal:  Taiwan J Ophthalmol       Date:  2018 Jul-Sep

Review 10.  Comparison of the Clinical Performance of Refractive Rotationally Asymmetric Multifocal IOLs with Other Types of IOLs: A Meta-Analysis.

Authors:  Zequan Xu; Wenzhe Li; Lianqun Wu; Shuang Xue; Xu Chen; Qiang Wu
Journal:  J Ophthalmol       Date:  2018-09-27       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.