Literature DB >> 22261486

Unselected percutaneous access with large vessel closure for endovascular aortic surgery: experience and predictors of technical success.

M J Metcalfe1, J R W Brownrigg, S A Black, T Loosemore, I M Loftus, M M Thompson.   

Abstract

INTRODUCTION: The effectiveness of percutaneous access with large vessel closure (pEVR) in non-selective groups of patients undergoing endovascular aneurysm repair (EVR) remains unclear. This study aims to identify factors that predict success in pEVR, performed using percutaneous access and the Prostar XL (Abbott Vascular, Redwood City, Calif) closure device.
METHOD: Consecutive patients who underwent pEVR between April 2010 and March 2011 were identified from a prospectively maintained database. Procedural and postoperative outcomes were compared with consecutive patients who underwent endovascular aneurysm repair using standard open femoral access between April 2008 and March 2009. To determine the predictors of technical success of pEVR, the association between clinical, anatomical and procedural variables with technical success, were examined in a multiple logistic regression model.
RESULTS: pEVR was attempted in 186 common femoral arteries (CFAs) with a technical success rate of 95.2% (177/186). Conventional open femoral access in the historic control group was performed in 208 CFAs. pEVR was associated with a reduced operation length (131 min [105-152] versus 150 min [124-195], p≤0.001) and length of stay (2 days [2-5] versus 4 days [2-7], p = 0.01) in patients undergoing infrarenal EVR. In secondary analysis of outcomes following percutaneous access in 91 CFAs, pre-operative renal failure, CFA depth (min and max), CFA diameter (min and max) and operator experience predicted success of percutaneous access in univariate analysis. Operator experience was the only independent predictor of technical success (p = 0.05) after adjustment for all confounding variables.
CONCLUSION: pEVR using the Prostar XL device is effective in the majority of patients. In this study there were benefits in terms of reduced postoperative complications, shorter procedures and decreased lengths of stay. Operator experience is a predictor of technical success for pEVR, irrespective of clinical and morphological characteristics at baseline. Copyright Â
© 2012 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22261486     DOI: 10.1016/j.ejvs.2011.12.025

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  6 in total

1.  Percutaneous thoracic endovascular aortic repair is not contraindicated in obese patients.

Authors:  Jason Zakko; Salvatore Scali; Adam W Beck; Charles T Klodell; Thomas M Beaver; Tomas D Martin; Thomas S Huber; Robert J Feezor
Journal:  J Vasc Surg       Date:  2014-05-17       Impact factor: 4.268

2.  [Arterial closure devices. What device for which clinical situation?].

Authors:  M Treitl; K M Eberhardt; D Maxien; B Behrends; M F Reiser
Journal:  Radiologe       Date:  2013-03       Impact factor: 0.635

Review 3.  Fascia Suture Technique and Suture-mediated Closure Devices: Systematic Review.

Authors:  Georgios Karaolanis; Ioannis D Kostakis; Demetrios Moris; Viktoria-Varvara Palla; Konstantinos G Moulakakis
Journal:  Int J Angiol       Date:  2018-01-22

4.  A comparison of Percutaneous femoral access in Endovascular Repair versus Open femoral access (PiERO): study protocol for a randomized controlled trial.

Authors:  Bastiaan P Vierhout; Ben R Saleem; Alewijn Ott; Jan Maarten van Dijl; Ties D van Andringa de Kempenaer; Maurice E N Pierie; Jan T Bottema; Clark J Zeebregts
Journal:  Trials       Date:  2015-09-14       Impact factor: 2.279

5.  Femoral Artery Closure Versus Surgical Cutdown for Endovascular Aortic Repair: A Single-Center Experience.

Authors:  Lin Yang; Jianlin Liu; Yanzi Li
Journal:  Med Sci Monit       Date:  2018-01-05

6.  Comparison of Early Efficacy of the Percutaneous Presuture Technique with the Femoral Artery Incision Technique in Endovascular Aortic Repair under Local Anesthesia for Uncomplicated Type B Aortic Dissection.

Authors:  Qingsong Wu; Debin Jiang; Xiaochai Lv; Jiaxin Zhang; Rongda Huang; Zhihuang Qiu; Liangwan Chen
Journal:  J Interv Cardiol       Date:  2022-08-22       Impact factor: 1.776

  6 in total