Effects of hydrofluoric acid and anodised micro and micro/nano surface implants on early osseointegration in rats.

Yongfeng Li1, Yuan Gao, Bo Shao, Jianrui Xiao, Kaijin Hu, Liang Kong.   

Abstract

Our aim was to evaluate the effects of hydrofluoric acid and anodised micro and micro/nano surface implants on bony ingrowth in the earliest stage of implantation in rats. Sixty cylindrical screwed titanium alloy implants with machined, micro, and hierarchical hybrid micro/nano surfaces (n=20 in each group) were inserted into the distal femurs of 30 female Sprague-Dawley rats. In vivo microcomputed tomography (micro CT) was used to assess microarchitectural changes in the bone around the implants 2 weeks after implantation. All the animals were then killed and the femurs with implants harvested for histological analysis and pull-out testing. Micro CT analysis showed that the trabecular thickness and the bone:volume ratio (bone volume:total volume) (BV:TV) increased significantly in the micro/nano group compared with the other two groups, while the trabecular separation decreased significantly in the micro/nano group compared with the machined group. The mean (SD) bone-implant contacts (%) were 38.94 (9.48), 41.67 (8.71), and 51.49 (12.49) in the machined, micro, and micro/nano groups, respectively. The maximum pull-out forces (N) were 64.95 (6.11), 71.45 (7.15), and 81.90 (13.1), respectively. Both bone-implant contacts and maximum pull-out forces were significantly higher in the micro/nano group, but there was no significant difference between the micro group and the machined group. These data indicate that the hierarchical hybrid micro/nano surface of the implant can promote osseointegration in the earliest stage of implantation, and may be a promising option for further clinical use.
Copyright © 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22257706     DOI: 10.1016/j.bjoms.2011.12.008

Source DB:  PubMed          Journal:  Br J Oral Maxillofac Surg        ISSN: 0266-4356            Impact factor:   1.651


  1 in total

1.  Characterization of Optimized TiO2 Nanotubes Morphology for Medical Implants: Biological Activity and Corrosion Resistance.

Authors:  Ricardo Pereira Nogueira; Jose Deuzimar Uchoa; Fanny Hilario; Gabriela de Fátima Santana-Melo; Luana Marotta Reis de Vasconcellos; Fernanda Roberta Marciano; Virginie Roche; Alberto Moreira Jorge Junior; Anderson Oliveira Lobo
Journal:  Int J Nanomedicine       Date:  2021-01-26
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.