Literature DB >> 22256112

Evaluation of a closed loop inductive power transmission system on an awake behaving animal subject.

Mehdi Kiani1, Ki Yong Kwon, Fei Zhang, Karim Oweiss, Maysam Ghovanloo.   

Abstract

This paper presents in vivo experimental results for a closed loop wireless power transmission system to implantable devices on an awake behaving animal subject. In this system, wireless power transmission takes place across an inductive link, controlled by a commercial off-the-shelf (COTS) radio frequency identification (RFID) transceiver (TRF7960) operating at 13.56 MHz. Induced voltage on the implantable secondary coil is rectified, digitized by a 10-bit analog to digital converter, and transmitted back to the primary via back telemetry. Transmitter (Tx) and receiver (Rx) circuitry were mounted on the back of an adult rat with a nominal distance of ~7 mm between their coils. Our experiments showed that the closed loop system was able to maintain the Rx supply voltage at the designated 3.8 V despite changes in the coils' relative distance and alignment due to animal movements. The Tx power consumption changed between 410 ~ 560 mW in order to deliver 27 mW to the receiver. The open loop system, on the other hand, showed undesired changes in the Rx supply voltage while the Tx power consumption was constant at 660 mW.

Entities:  

Mesh:

Year:  2011        PMID: 22256112      PMCID: PMC3261583          DOI: 10.1109/IEMBS.2011.6091887

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  6 in total

1.  Feedback analysis and design of RF power links for low-power bionic systems.

Authors:  M W Baker; R Sarpeshkar
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2007-03       Impact factor: 3.833

2.  Experimental Study of a TET System for Implantable Biomedical Devices.

Authors:  T D Dissanayake; A P Hu; S Malpas; L Bennet; A Taberner; L Booth; D Budgett
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2009-12       Impact factor: 3.833

3.  Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission.

Authors:  M Ghovanloo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2007-09       Impact factor: 3.833

4.  An RFID-Based Closed-Loop Wireless Power Transmission System for Biomedical Applications.

Authors:  Mehdi Kiani; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst II Express Briefs       Date:  2010-04-01       Impact factor: 3.292

5.  An Integrated Power-Efficient Active Rectifier With Offset-Controlled High Speed Comparators for Inductively Powered Applications.

Authors:  Hyung-Min Lee; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst I Regul Pap       Date:  2011       Impact factor: 3.605

6.  A closed loop wireless power transmission system using a commercial RFID transceiver for biomedical applications.

Authors:  Mehdi Kiani; Maysam Ghovanloo
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009
  6 in total
  4 in total

1.  A Fully Implantable, Programmable and Multimodal Neuroprocessor for Wireless, Cortically Controlled Brain-Machine Interface Applications.

Authors:  Fei Zhang; Mehdi Aghagolzadeh; Karim Oweiss
Journal:  J Signal Process Syst       Date:  2011-06-15

2.  Geometrical Design of a Scalable Overlapping Planar Spiral Coil Array to Generate a Homogeneous Magnetic Field.

Authors:  Uei-Ming Jow; Maysam Ghovanloo
Journal:  IEEE Trans Magn       Date:  2012-12-21       Impact factor: 1.700

3.  A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links.

Authors:  Mehdi Kiani; Maysam Ghovanloo
Journal:  IEEE Trans Ind Electron       Date:  2012-11-16       Impact factor: 8.236

4.  A flexible, stretchable system for simultaneous acoustic energy transfer and communication.

Authors:  Peng Jin; Ji Fu; Fengle Wang; Yingchao Zhang; Peng Wang; Xin Liu; Yang Jiao; Hangfei Li; Ying Chen; Yinji Ma; Xue Feng
Journal:  Sci Adv       Date:  2021-09-29       Impact factor: 14.136

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.