Literature DB >> 22255098

Series elastic actuator control of a powered exoskeleton.

Daniel Ragonesi1, Sunil Agrawal, Whitney Sample, Tariq Rahman.   

Abstract

A motorized upper extremity orthosis based on the passive WREX system is being developed. The orthosis is a 4 dof arm controlled by user residual force inputs. The arm is intended for people with neuromuscular weakness due to muscular dystrophy or spinal muscular atrophy. Previous work determined that actuation in parallel with gravity balancing springs required less torque than actuation in series. Compliance is achieved by using a series elastic actuator (SEA) by placing torsional springs between the motors and the WREX. A torque control was implemented on the SEA at the joint level. The response of the control law was characterized without disturbances. The SEAs were then attached to the orthosis to test the response with disturbances, and the control provided accurate joint torques.

Entities:  

Mesh:

Year:  2011        PMID: 22255098     DOI: 10.1109/IEMBS.2011.6090583

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  6 in total

1.  Comparison of Two Series Elastic Actuator Designs Incorporated into a Shoulder Exoskeleton.

Authors:  Rafael Casas; Tianyao Chen; Peter S Lum
Journal:  IEEE Int Conf Rehabil Robot       Date:  2019-06

Review 2.  Non-invasive control interfaces for intention detection in active movement-assistive devices.

Authors:  Joan Lobo-Prat; Peter N Kooren; Arno H A Stienen; Just L Herder; Bart F J M Koopman; Peter H Veltink
Journal:  J Neuroeng Rehabil       Date:  2014-12-17       Impact factor: 4.262

3.  Low-back electromyography (EMG) data-driven load classification for dynamic lifting tasks.

Authors:  Deema Totah; Lauro Ojeda; Daniel D Johnson; Deanna Gates; Emily Mower Provost; Kira Barton
Journal:  PLoS One       Date:  2018-02-15       Impact factor: 3.240

4.  Comparison between sEMG and force as control interfaces to support planar arm movements in adults with Duchenne: a feasibility study.

Authors:  Joan Lobo-Prat; Kostas Nizamis; Mariska M H P Janssen; Arvid Q L Keemink; Peter H Veltink; Bart F J M Koopman; Arno H A Stienen
Journal:  J Neuroeng Rehabil       Date:  2017-07-12       Impact factor: 4.262

5.  Development and evaluation of a soft wearable weight support device for reducing muscle fatigue on shoulder.

Authors:  Daegeun Park; Kyu-Jin Cho
Journal:  PLoS One       Date:  2017-03-14       Impact factor: 3.240

6.  Evaluation of EMG, force and joystick as control interfaces for active arm supports.

Authors:  Joan Lobo-Prat; Arvid Q L Keemink; Arno H A Stienen; Alfred C Schouten; Peter H Veltink; Bart F J M Koopman
Journal:  J Neuroeng Rehabil       Date:  2014-04-19       Impact factor: 4.262

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.