Literature DB >> 22254528

A novel mainstream capnometer system for non-intubated pediatric patients requiring oxygen administration.

Fumihiko Takatori1, Shinji Yamamori, Masayuki Inoue, Seiki Abe, Katsuyuki Miyasaka.   

Abstract

Capnometer has been widely used as a respiratory monitor. Stable carbon dioxide (CO(2)) monitoring of non-intubated patient is especially problematic due to the frequent occurrence of tube obstruction and it could be even more difficult when oxygen is being administered. Oxygen is often administered by an oxygen mask or oxygen nasal cannula; however there are some problems with these methods. For oxygen masks, it is necessary to provide high-flow oxygen to prevent rebreathing of exhaled CO(2), and as for oxygen nasal cannula, it is incapable of increasing the oxygen concentration and patient may feel uncomfortable during oxygen administration because it could dry nasal mucous. To solve these problems, we developed a novel mainstream capnometer system, which provides stable monitoring of exhaled CO(2) while administering oxygen. This capnometer system has a mask with an opening large enough to facilitate the observation of patient's nose and mouth and the procedures such as daily oral care. Furthermore, the outer rim of the mask is designed to effectively retain oxygen flow without causing rebreathing.

Entities:  

Mesh:

Year:  2011        PMID: 22254528     DOI: 10.1109/IEMBS.2011.6090279

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Accuracy of CO₂ monitoring via nasal cannulas and oral bite blocks during sedation for esophagogastroduodenoscopy.

Authors:  Kuo-Chen Chang; Joe Orr; Wei-Chih Hsu; Lu Yu; Mei-Yung Tsou; Dwayne R Westenskow; Chien-Kun Ting
Journal:  J Clin Monit Comput       Date:  2015-04-21       Impact factor: 2.502

2.  Novel mainstream capnometer system is safe and feasible even under CO2 insufflation during ERCP-related procedure: a pilot study.

Authors:  Yoichi Takimoto; Eisuke Iwasaki; Tatsuhiro Masaoka; Seiichiro Fukuhara; Shintaro Kawasaki; Takashi Seino; Tadashi Katayama; Kazuhiro Minami; Hiroki Tamagawa; Yujiro Machida; Haruhiko Ogata; Takanori Kanai
Journal:  BMJ Open Gastroenterol       Date:  2019-02-28

3.  Tribute to Dr. Takuo Aoyagi, inventor of pulse oximetry.

Authors:  Katsuyuki Miyasaka; Kirk Shelley; Shosuke Takahashi; Hironami Kubota; Kazumasa Ito; Ikuto Yoshiya; Akio Yamanishi; Jeffrey B Cooper; David J Steward; Hiroshi Nishida; Joe Kiani; Hirokazu Ogino; Yasuhiko Sata; Robert J Kopotic; Kitty Jenkin; Alex Hannenberg; Atul Gawande
Journal:  J Anesth       Date:  2021-08-02       Impact factor: 2.078

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.