Literature DB >> 22249280

Cystocele repair by vaginal route: comparison of three different surgical techniques of mesh placement.

Pascal Mourtialon1, Vincent Letouzey, Georges Eglin, Renaud de Tayrac.   

Abstract

INTRODUCTION AND HYPOTHESIS: Different techniques of mesh placement for cystocele repair are known. Our goal was to compare anatomical and functional outcomes of three different techniques of mesh placement over a 3-year follow-up.
METHODS: Between March 2003 and June 2004, 230 patients (stage 2-4 pelvic organ prolapse (POP)) were included in a prospective study. For cystocele repair, mesh was implanted either with two arms into the retropubic space (RP) or with two to four arms into the obturator foramen (TO), or fixed to the arcus tendineous fascia pelvis (FG).
RESULTS: Patients' distribution is as follows: 142 TO, 32 RP, and 31 FG. Anatomical success (cystocele < stage 2 in the POP staging system) was clearly poorer after the retropubic free technique, with success rates of 69% (RP), 90.1% (TO), and 96.6% (FG) (p = 0.004). POP distress inventory (p < 0.005) and POP impact questionnaire scores were both significantly poorer after RP.
CONCLUSIONS: RP technique is less effective than TO and FG techniques.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22249280     DOI: 10.1007/s00192-011-1650-6

Source DB:  PubMed          Journal:  Int Urogynecol J        ISSN: 0937-3462            Impact factor:   2.894


  29 in total

1.  [Transobturator subvesical mesh. Tolerance and short-term results of a 103 case continuous series].

Authors:  G Eglin; J M Ska; X Serres
Journal:  Gynecol Obstet Fertil       Date:  2003-01

2.  Transvaginal cystocele repair with polypropylene mesh using a tension-free technique.

Authors:  M Cervigni; F Natale; C La Penna; M Panei; A Mako
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2007-11-07

3.  Vaginal versus abdominal reconstructive surgery for the treatment of pelvic support defects: a prospective randomized study with long-term outcome evaluation.

Authors:  J T Benson; V Lucente; E McClellan
Journal:  Am J Obstet Gynecol       Date:  1996-12       Impact factor: 8.661

4.  [Quality of life instruments for women with pelvic organ prolapse].

Authors:  R de Tayrac; A Chauveaud-Lambling; D Fernandez; H Fernandez
Journal:  J Gynecol Obstet Biol Reprod (Paris)       Date:  2003-10

5.  Tension-free polypropylene mesh for vaginal repair of anterior vaginal wall prolapse.

Authors:  Renaud de Tayrac; Amélie Gervaise; Aurélia Chauveaud; Hervé Fernandez
Journal:  J Reprod Med       Date:  2005-02       Impact factor: 0.142

6.  Transvaginal repair of anterior and posterior compartment prolapse with Atrium polypropylene mesh.

Authors:  Peter L Dwyer; Barry A O'Reilly
Journal:  BJOG       Date:  2004-08       Impact factor: 6.531

7.  Sexual function in women before and after transvaginal mesh repair for pelvic organ prolapse.

Authors:  Loïc Sentilhes; Aurélien Berthier; Fabrice Sergent; Eric Verspyck; Philippe Descamps; Loïc Marpeau
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2008-06

8.  Low-weight polypropylene mesh for anterior vaginal wall prolapse: a randomized controlled trial.

Authors:  Reijo Hiltunen; Kari Nieminen; Teuvo Takala; Eila Heiskanen; Mauri Merikari; Kirsti Niemi; Pentti K Heinonen
Journal:  Obstet Gynecol       Date:  2007-08       Impact factor: 7.661

9.  Retrospective multicentre study of the new minimally invasive mesh repair devices for pelvic organ prolapse.

Authors:  M Abdel-Fattah; I Ramsay
Journal:  BJOG       Date:  2008-01       Impact factor: 6.531

10.  Transvaginal repair of genital prolapse: preliminary results of a new tension-free vaginal mesh (Prolift technique)--a case series multicentric study.

Authors:  B Fatton; J Amblard; P Debodinance; M Cosson; B Jacquetin
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2006-11-28
View more
  5 in total

1.  Central compartment and apical defect repair using synthetic mesh.

Authors:  Karen Soules; J Christian Winters; Christopher J Chermansky
Journal:  Curr Urol Rep       Date:  2012-06       Impact factor: 3.092

2.  Mesh pullout force: comparative study of different deployment techniques in a sheep model.

Authors:  Menachem Alcalay; Miron Livneh; Naama Marcus Braun; Yariv Siman Tov; Eitan Hod
Journal:  Int Urogynecol J       Date:  2013-07-03       Impact factor: 2.894

Review 3.  Where to for pelvic organ prolapse treatment after the FDA pronouncements? A systematic review of the recent literature.

Authors:  J M van Geelen; P L Dwyer
Journal:  Int Urogynecol J       Date:  2013-01-10       Impact factor: 2.894

4.  Transobturator four-arms mesh in the surgical management of cystocele: a long-term follow-up.

Authors:  Jin Long; Chung Lyul Lee; Seung Woo Yang; Ji Yong Lee; Jae Geun Lee; Ki Hak Song; Jae Sung Lim; Jong Mok Park; Yong Gil Na; Geon Gil; Ju Hyun Shin
Journal:  J Exerc Rehabil       Date:  2021-02-23

5.  Transvaginal cystocele repair by purse-string technique reinforced with three simple sutures: surgical technique and results.

Authors:  Ho-Sook Song; Gwoan Youb Choo; Long-Hu Jin; Sang-Min Yoon; Tack Lee
Journal:  Int Neurourol J       Date:  2012-09-30       Impact factor: 2.835

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.