Literature DB >> 22246917

DANTE-prepared pulse trains: a novel approach to motion-sensitized and motion-suppressed quantitative magnetic resonance imaging.

Linqing Li1, Karla L Miller, Peter Jezzard.   

Abstract

Delay alternating with nutation for tailored excitation (DANTE) pulse trains are well appreciated as frequency-selective excitation methods in Fourier transform NMR and for spatial tagging in MRI. In this study, nonselective DANTE pulse trains are used in combination with gradient pulses and short repetition times as motion-sensitive preparation modules. We show that while the longitudinal magnetization of static tissue is mostly preserved, flowing spins are largely (or fully) attenuated as they fail to establish transverse steady state due to a spoiling effect caused by flow along the applied gradient. The attenuation of flowing spins is effectively insensitive to spin velocity (above a low threshold) and can be approximately quantified with a simple T₁ longitudinal magnetization decay model. The relevant analytical equations for moving spins and static spins during DANTE module application are derived for both transient and steady state epochs. The equations are validated by comparing analytical solutions and numerical Bloch equation simulations against experimental observations in phantoms and in vivo. Based on this contrast mechanism, the application of the DANTE preparation to black blood vessel imaging is proposed. A simple demonstration of DANTE black blood imaging modules shows that it provides excellent blood signal suppression and static tissue signal preservation.
Copyright © 2012 Wiley Periodicals, Inc.

Mesh:

Year:  2012        PMID: 22246917     DOI: 10.1002/mrm.24142

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  45 in total

1.  Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

Authors:  Yibin Xie; Qi Yang; Guoxi Xie; Jianing Pang; Zhaoyang Fan; Debiao Li
Journal:  Magn Reson Med       Date:  2015-07-08       Impact factor: 4.668

2.  Cerebral Venous Thrombosis: MR Black-Blood Thrombus Imaging with Enhanced Blood Signal Suppression.

Authors:  G Wang; X Yang; J Duan; N Zhang; M M Maya; Y Xie; X Bi; X Ji; D Li; Q Yang; Z Fan
Journal:  AJNR Am J Neuroradiol       Date:  2019-09-26       Impact factor: 3.825

3.  Composite MRA: statistical approach to generate an MR angiogram from multiple contrasts.

Authors:  Dahan Kim; Myriam Edjlali; Patrick Turski; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2019-09-25       Impact factor: 4.668

4.  Lymphedema evaluation using noninvasive 3T MR lymphangiography.

Authors:  Rachelle Crescenzi; Paula M C Donahue; Katherine G Hartley; Aditi A Desai; Allison O Scott; Vaughn Braxton; Helen Mahany; Sarah K Lants; Manus J Donahue
Journal:  J Magn Reson Imaging       Date:  2017-02-28       Impact factor: 4.813

5.  Interchangeable neck shape-specific coils for a clinically realizable anterior neck phased array system.

Authors:  Michael J Beck; Dennis L Parker; Bradley D Bolster; Seong-Eun Kim; J Scott McNally; Gerald S Treiman; J Rock Hadley
Journal:  Magn Reson Med       Date:  2017-02-10       Impact factor: 4.668

6.  Assessment of quantitative methods for enhancement measurement on vessel wall magnetic resonance imaging evaluation of intracranial atherosclerosis.

Authors:  Matthew D Alexander; Adam de Havenon; Seong-Eun Kim; Dennis L Parker; Joseph S McNally
Journal:  Neuroradiology       Date:  2019-01-24       Impact factor: 2.804

7.  Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.

Authors:  D Kim; Y J Heo; H W Jeong; J W Baek; J-Y Han; J Y Lee; S-C Jin; H J Baek
Journal:  AJNR Am J Neuroradiol       Date:  2019-08-01       Impact factor: 3.825

8.  Joint intracranial and carotid vessel wall imaging in 5 minutes using compressed sensing accelerated DANTE-SPACE.

Authors:  Sen Jia; Lei Zhang; Lijie Ren; Yulong Qi; Jinhao Ly; Na Zhang; Ye Li; Xin Liu; Hairong Zheng; Dong Liang; Yiu-Cho Chung
Journal:  Eur Radiol       Date:  2019-08-01       Impact factor: 5.315

9.  Breath-hold black blood quantitative T1rho imaging of liver using single shot fast spin echo acquisition.

Authors:  Weitian Chen; Queenie Chan; Yì-Xiáng J Wáng
Journal:  Quant Imaging Med Surg       Date:  2016-04

Review 10.  Three-Dimensional Carotid Plaque MR Imaging.

Authors:  Chun Yuan; Dennis L Parker
Journal:  Neuroimaging Clin N Am       Date:  2015-10-19       Impact factor: 2.264

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.