Literature DB >> 22246646

ARFI-prepared MRgHIFU in liver: simultaneous mapping of ARFI-displacement and temperature elevation, using a fast GRE-EPI sequence.

Vincent Auboiroux1, Magalie Viallon, Joerg Roland, Jean-Noël Hyacinthe, Lorena Petrusca, Denis R Morel, Thomas Goget, Sylvain Terraz, Patrick Gross, Christoph D Becker, Rares Salomir.   

Abstract

MR acoustic radiation force imaging (ARFI) is an elegant adjunct to MR-guided high intensity focused ultrasound for treatment planning and optimization, permitting in situ assessment of the focusing and targeting quality. The thermal effect of high intensity focused ultrasound pulses associated with ARFI measurements is recommended to be monitored on line, in particular when the beam crosses highly absorbent structures or interfaces (e.g., bones or air-filled cavities). A dedicated MR sequence is proposed here, derived from a segmented gradient echo-echo planar imaging kernel by adding a bipolar motion encoding gradient with interleaved alternating polarities. Temporal resolution was reduced to 2.1 s, with in-plane spatial resolution of 1 mm. MR-ARFI measurements were executed during controlled animal breathing, with trans-costal successively steered foci, to investigate the spatial modulation of the focus intensity and the targeting offset. ARFI-induced tissue displacement measurements enabled the accurate localization, in vivo, of the high intensity focused ultrasound focal point in sheep liver, with simultaneous monitoring of the temperature elevation. ARFI-based precalibration of the focal point position was immediately followed by trans-costal MR-guided high intensity focused ultrasound ablation, monitored with a conventional proton resonance frequency shift MR thermometry sequence. The latter MR thermometry sequence had spatial resolution and geometrical distortion identical with the ARFI maps, hence no coregistration was required.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22246646     DOI: 10.1002/mrm.23309

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

Review 1.  MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics.

Authors:  Alberto Bazzocchi; Alessandro Napoli; Beatrice Sacconi; Giuseppe Battista; Giuseppe Guglielmi; Carlo Catalano; Ugo Albisinni
Journal:  Br J Radiol       Date:  2015-11-26       Impact factor: 3.039

2.  Multi-echo MR thermometry using iterative separation of baseline water and fat images.

Authors:  Megan E Poorman; Ieva Braškutė; Lambertus W Bartels; William A Grissom
Journal:  Magn Reson Med       Date:  2018-11-05       Impact factor: 4.668

3.  High sensitivity MR acoustic radiation force imaging using transition band balanced steady-state free precession.

Authors:  Yuan Zheng; Michael Marx; G Wilson Miller; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2017-06-20       Impact factor: 4.668

4.  Fast PRF-based MR thermometry using double-echo EPI: in vivo comparison in a clinical hyperthermia setting.

Authors:  Tetiana Dadakova; Johanna Gellermann; Otilia Voigt; Jan Gerrit Korvink; John Matthew Pavlina; Jürgen Hennig; Michael Bock
Journal:  MAGMA       Date:  2014-11-08       Impact factor: 2.310

5.  A simulation technique for 3D MR-guided acoustic radiation force imaging.

Authors:  Allison Payne; Josh de Bever; Alexis Farrer; Brittany Coats; Dennis L Parker; Douglas A Christensen
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

6.  High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI).

Authors:  Yang Han; Gary Yi Hou; Shutao Wang; Elisa Konofagou
Journal:  Phys Med Biol       Date:  2015-07-17       Impact factor: 3.609

7.  Acoustic radiation force imaging using a single-shot spiral readout.

Authors:  Asaf Ilovitsh; Brett Z Fite; Tali Ilovitsh; Katherine W Ferrara
Journal:  Phys Med Biol       Date:  2019-06-10       Impact factor: 3.609

8.  A method to convert MRI images of temperature change into images of absolute temperature in solid tumours.

Authors:  Ryan M Davis; Benjamin L Viglianti; Pavel Yarmolenko; Ji-Young Park; Paul Stauffer; David Needham; Mark W Dewhirst
Journal:  Int J Hyperthermia       Date:  2013-09       Impact factor: 3.914

9.  Histologic safety of transcranial focused ultrasound neuromodulation and magnetic resonance acoustic radiation force imaging in rhesus macaques and sheep.

Authors:  Pooja Gaur; Kerriann M Casey; Jan Kubanek; Ningrui Li; Morteza Mohammadjavadi; Yamil Saenz; Gary H Glover; Donna M Bouley; Kim Butts Pauly
Journal:  Brain Stimul       Date:  2020-02-21       Impact factor: 8.955

10.  Evaluation of a three-dimensional MR acoustic radiation force imaging pulse sequence using a novel unbalanced bipolar motion encoding gradient.

Authors:  Joshua T de Bever; Henrik Odéen; Nick Todd; Alexis I Farrer; Dennis L Parker
Journal:  Magn Reson Med       Date:  2015-10-07       Impact factor: 4.668

View more