Literature DB >> 22246547

Objective measurement devices to assess static rotational knee laxity: focus on the Rotameter.

Olaf Lorbach1, Matthias Brockmeyer, Matthias Kieb, Tina Zerbe, Dietrich Pape, Romain Seil.   

Abstract

PURPOSE: The present article summarizes the development of a simple, objective, and non-invasive measurement device for tibiofemoral rotation to assess static rotational knee laxity. METHODS AND
RESULTS: The device is based on the dial test with the patient lying prone and the knee flexed to 30°. From measurements of 30 healthy participants, the device achieved high inter- and intra-observer reliability and showed a high correlation of the measured results with the contralateral knees of the participants. Measurements of the device were also performed in a human cadaver study and revealed highly correlated results when compared to the simultaneous measurements of a knee navigation system, which was used as an invasive standard method to assess tibial rotation. In human cadaver specimens, it was shown that a simulated tear of the posterolateral bundle as well as a complete ACL tear led to a significant increase in isolated tibiofemoral rotation compared to the intact ACL. A retrospective case series investigated the clinical results as well as knee laxity measurements after ACL surgery in vivo. Rotational, as well as anteroposterior (AP), knee laxity was objectively assessed in 52 patients at a mean postoperative follow-up of 27 months by comparing the measured results with the results of the contralateral unaffected knee in each patient. The clinical results were comparable to the results reported in the literature. Moreover, rotational laxity was successfully restored after ACL reconstruction, whereas AP laxity showed significant differences compared to the contralateral knees although they were defined as clinically successful according to the IKDC classification.
CONCLUSIONS: A non-invasive and objective knee rotational measurement device has been developed, which offers good potential for objective quality control in knee ligament injuries and their treatment. LEVEL OF EVIDENCE: Review article, Level IV.

Entities:  

Mesh:

Year:  2012        PMID: 22246547     DOI: 10.1007/s00167-011-1876-3

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  30 in total

1.  Double-bundle versus single-bundle anterior cruciate ligament reconstruction: a prospective, randomize clinical study.

Authors:  Timo Järvelä
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-01-10       Impact factor: 4.342

2.  Double-bundle ACL reconstruction can improve rotational stability.

Authors:  Masayoshi Yagi; Ryosuke Kuroda; Kouki Nagamune; Shinichi Yoshiya; Masahiro Kurosaka
Journal:  Clin Orthop Relat Res       Date:  2007-01       Impact factor: 4.176

3.  Measurement of varus-valgus and internal-external rotational knee laxities in vivo--Part I: assessment of measurement reliability and bilateral asymmetry.

Authors:  Sandra J Shultz; Yohei Shimokochi; Anh-Dung Nguyen; Randy J Schmitz; Bruce D Beynnon; David H Perrin
Journal:  J Orthop Res       Date:  2007-08       Impact factor: 3.494

4.  A new knee arthrometer, the GNRB: experience in ACL complete and partial tears.

Authors:  H Robert; S Nouveau; S Gageot; B Gagnière
Journal:  Orthop Traumatol Surg Res       Date:  2009-05-07       Impact factor: 2.256

5.  The anterior cruciate ligament does play a role in controlling axial rotation in the knee.

Authors:  H N Andersen; P Dyhre-Poulsen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1997       Impact factor: 4.342

6.  Is the KT1000 knee ligament arthrometer reliable?

Authors:  I W Forster; C D Warren-Smith; M Tew
Journal:  J Bone Joint Surg Br       Date:  1989-11

7.  Articular mobility in an African population.

Authors:  P Beighton; L Solomon; C L Soskolne
Journal:  Ann Rheum Dis       Date:  1973-09       Impact factor: 19.103

8.  Instrumented measurement of anterior laxity of the knee.

Authors:  D M Daniel; L L Malcom; G Losse; M L Stone; R Sachs; R Burks
Journal:  J Bone Joint Surg Am       Date:  1985-06       Impact factor: 5.284

9.  The anterior cruciate ligament in controlling axial rotation. An evaluation of its effect.

Authors:  J G Lane; S E Irby; K Kaufman; C Rangger; D M Daniel
Journal:  Am J Sports Med       Date:  1994 Mar-Apr       Impact factor: 6.202

10.  In vivo rotatory knee stability. Ligamentous and muscular contributions.

Authors:  S C Shoemaker; K L Markolf
Journal:  J Bone Joint Surg Am       Date:  1982-02       Impact factor: 5.284

View more
  6 in total

1.  Global rotation has high sensitivity in ACL lesions within stress MRI.

Authors:  João Espregueira-Mendes; Renato Andrade; Ana Leal; Hélder Pereira; Abdala Skaf; Sérgio Rodrigues-Gomes; J Miguel Oliveira; Rui L Reis; Rogério Pereira
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-16       Impact factor: 4.342

2.  An analysis of normative data on the knee rotatory profile and the usefulness of the Rotatometer, a new instrument for measuring tibiofemoral rotation: the reliability of the knee Rotatometer.

Authors:  Ju Hwan Chung; Keun Jung Ryu; Dong Hoon Lee; Kyung Ho Yoon; Yang Woo Park; Hyung Jong Kim; Jae Hwa Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-10       Impact factor: 4.342

3.  Measurements of tibial rotation during a simulated pivot shift manoeuvre using a gyroscopic sensor.

Authors:  Frank A Petrigliano; Per Henrik Borgstrom; William J Kaiser; David R McAllister; Keith L Markolf
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-11       Impact factor: 4.342

4.  Repeatability and accuracy of a non-invasive method of measuring internal and external rotation of the tibia.

Authors:  David F Russell; Angela H Deakin; Quentin A Fogg; Frederic Picard
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-12-27       Impact factor: 4.342

5.  A Preliminary In Vivo Assessment of Anterior Cruciate Ligament-Deficient Knee Kinematics With the KneeM Device: A New Method to Assess Rotatory Laxity Using Open MRI.

Authors:  Nicolas Tardy; Philippe Marchand; Pascal Kouyoumdjian; Dominique Blin; Christophe Demattei; Gérard Asencio
Journal:  Orthop J Sports Med       Date:  2014-03-13

6.  Rater agreement reliability of the dial test in the ACL-deficient knee.

Authors:  Malou E Slichter; Nienke Wolterbeek; K Gie Auw Yang; Jacco A C Zijl; Tom M Piscaer
Journal:  J Exp Orthop       Date:  2018-06-14