Literature DB >> 22245462

Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy.

Takashi Kojima1, Sho Yokoyama, Mayuka Ito, Rie Horai, Shuya Hara, Tomoaki Nakamura, Kazuo Ichikawa.   

Abstract

PURPOSE: To develop and evaluate a new implantable collamer lens (ICL) sizing method that uses high-frequency ultrasound biomicroscopy (UBM).
DESIGN: Interventional case series.
METHODS: ICL were implanted in 47 eyes of 25 patients (8 male, 17 female, mean age 34.7±6.8 years). At 3 months after ICL surgery, the vault (distance between ICL and crystalline lens) was measured using anterior optical coherence tomography (OCT). Stepwise multiple regression analysis was performed in order to determine the optimal ICL size that will be expected to achieve a 0.5-mm vault, and the regression equation was calculated. Mean keratometric power, axial length, anterior chamber depth, sulcus-to-sulcus (STS) diameter, and distance between STS plane and crystalline lens were applied as candidates for explanatory variables. Subsequently, the equation was applied to a new group of patients (81 eyes of 43 patients, 20 male and 23 female, mean age 35.6±7.2 years) in order to decide the ICL size. Postoperative vault was evaluated at 3 months after surgery. Main outcome measures were mean postoperative vault and percentages of eyes that achieved moderate vault.
RESULTS: The regression equation was determined using 3 explanatory variables: anterior chamber depth (ACD), STS diameter, and distance between STS plane and anterior crystalline lens surface (STSL). The mean vault error (postoperative vault-predicted vault) was -0.06±0.29 mm. Of the total number of eyes, 88.9% had a vault between 0.15 and 1.0 mm. None of the eyes had a low vault (<0.15 mm). Nine eyes (11.1%) had a high vault (>1.0 mm).
CONCLUSION: A novel ICL sizing equation was developed and shown to be an effective method for calculation of the optimal ICL size in order to achieve an appropriate vault. Copyright Â
© 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22245462     DOI: 10.1016/j.ajo.2011.06.031

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  19 in total

1.  Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation.

Authors:  Jing Zhang; Hui-Hui Luo; Jing Zhuang; Ke-Ming Yu
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

2.  Repeatability and agreement of two anterior segment OCT in myopic patients before implantable collamer lenses implantation.

Authors:  Xi-Fang Zhang; Meng Li; Yan Shi; Xiu-Hua Wan; Huai-Zhou Wang
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

3.  Outcomes and complications of implantable collamer lens for mild to advance keratoconus.

Authors:  Rafah Fairaq; Mohammed Almutlak; Enmar Almazyad; Abdulrahman H Badawi; Muhammad Ali Ahad
Journal:  Int Ophthalmol       Date:  2021-03-27       Impact factor: 2.031

4.  Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology.

Authors:  Zhikun Yang; Lihui Meng; Xinyu Zhao; Youxin Chen; Yan Luo
Journal:  Front Med (Lausanne)       Date:  2022-06-09

5.  Inter-eye and postoperative prediction of vault after implantation of EVO + Visian phakic implantable collamer lens.

Authors:  Elena Martínez-Plaza; Alberto López-Miguel; Alberto López-de la Rosa; Miguel J Maldonado
Journal:  Int Ophthalmol       Date:  2022-10-19       Impact factor: 2.029

6.  Pseudophacomorphic Glaucoma along with Pupillary Block after Visian™ Implantable Collamer Lens Implantation for High Myopia.

Authors:  Michael V McCaughey; Thomas Mifflin; Carlton R Fenzl; Jason Goldsmith; Majid Moshirfar
Journal:  Open J Ophthalmol       Date:  2014-11

7.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

Review 8.  Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

Authors:  Mark Packer
Journal:  Clin Ophthalmol       Date:  2016-06-09

9.  Buffering zone of implantable Collamer lens sizing in V4c.

Authors:  Seung Wan Nam; Dong Hui Lim; Joo Hyun; Eui-Sang Chung; Tae-Young Chung
Journal:  BMC Ophthalmol       Date:  2017-12-22       Impact factor: 2.209

10.  In Vivo Positional Analysis of Implantable Collamer Lens Using Ultrasound Biomicroscopy.

Authors:  Ahmed Mohamed Kamal Elshafei; Mahmoud Mohamed Genaidy; Hossam Mohamed Moharram
Journal:  J Ophthalmol       Date:  2016-09-08       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.