Literature DB >> 22244001

The incremental value of valvuloarterial impedance in evaluating the results of transcatheter aortic valve implantation in symptomatic aortic stenosis.

Cristina Giannini1, Anna Sonia Petronio, Marco De Carlo, Fabio Guarracino, Giovanni Benedetti, Maria Grazia Delle Donne, Frank Loyd Dini, Mario Marzilli, Vitantonio Di Bello.   

Abstract

BACKGROUND: Valvuloarterial impedance (Z(va)) can estimate the global hemodynamic load on the left ventricle in patients with severe aortic stenosis better than the standard indexes, as shown in previous studies. In fact, Z(va) can estimate global left ventricular hemodynamic load as the sum of valvular and vascular loads. The aim of this study was to evaluate the acute improvement of left ventricular performance in patients with symptomatic aortic stenosis after transcatheter aortic valve implantation (TAVI) using Z(va).
METHODS: One hundred two consecutive patients who underwent TAVI were submitted to transthoracic echocardiography immediately before and after aortic valve implantation, together with invasive hemodynamic measurements.
RESULTS: After TAVI, immediate reductions in the transaortic peak pressure gradient (P < .0001) and mean pressure gradient (P < .0001) and a concomitant increase in aortic valve area (P < .0001) were seen on echocardiography. Left ventricular ejection fraction significantly increased immediately after TAVI in all patients (from 48.9 ± 10.3% to 52.1 ± 11.1%, P < .0001). Regarding global left ventricular hemodynamic load, acute and significant reductions in end-systolic meridional wall stress (from 82.7 ± 42.6 to 57.8 ± 30.1 kdyne · cm(-2), P < .0001) and in Z(va) (from 6.81 ± 2.51 to 5.38 ± 2.13 mm Hg · mL(-1) · m(-2), P < .0001) were observed. Furthermore, patients who died at 6-month follow-up had higher baseline Z(va) values compared with those who were alive at 6-month follow-up (8.13 ± 3.08 vs 6.41 ± 2.12 mm Hg · mL(-1) · m(-2), P < .004).
CONCLUSIONS: TAVI is characterized by an immediate enhancement of global left ventricular hemodynamic performance, as demonstrated by an acute Z(va) improvement, even in patients with low baseline ejection fractions.
Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22244001     DOI: 10.1016/j.echo.2011.12.008

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  8 in total

1.  Dynamic changes in aortic impedance after transcatheter aortic valve replacement and its impact on exploratory outcome.

Authors:  Yukari Kobayashi; Juyong B Kim; Kegan J Moneghetti; Yuhei Kobayashi; Ran Zhang; Daniel A Brenner; Ryan O'Malley; Ingela Schnittger; Michael Fischbein; D Craig Miller; Alan C Yeung; David Liang; Francois Haddad; William F Fearon
Journal:  Int J Cardiovasc Imaging       Date:  2017-05-17       Impact factor: 2.357

2.  Left ventricular function and the systemic arterial vasculature: remembering what we have learned.

Authors:  Brian P Davidson; George D Giraud
Journal:  J Am Soc Echocardiogr       Date:  2012-08       Impact factor: 5.251

Review 3.  New Evidence About Aortic Valve Stenosis and Cardiovascular Hemodynamics.

Authors:  Costantino Mancusi; Edda Bahlmann; Christian Basile; Eva Gerdts
Journal:  High Blood Press Cardiovasc Prev       Date:  2022-04-19

4.  The Role of Index of Valvular-Arterial Impedance and Systemic Arterial Compliance after Aortic Valve Replacement.

Authors:  Sung-Ji Park
Journal:  J Cardiovasc Ultrasound       Date:  2016-09-26

5.  Impact of Valvuloarterial Impedance on Concentric Remodeling in Aortic Stenosis and Its Regression after Valve Replacement.

Authors:  Jeong Yoon Jang; Jeong-Sook Seo; Byung Joo Sun; Dae-Hee Kim; Jong-Min Song; Duk-Hyun Kang; Jae-Kwan Song
Journal:  J Cardiovasc Ultrasound       Date:  2016-09-26

Review 6.  Hypertension and transcatheter aortic valve replacement: parallel or series?

Authors:  Nidhish Tiwari; Nidhi Madan
Journal:  Integr Blood Press Control       Date:  2018-11-23

7.  A novel echocardiographic hemodynamic index for predicting outcome of aortic stenosis patients following transcatheter aortic valve replacement.

Authors:  Altayyeb Yousef; Benjamin Hibbert; Joshua Feder; Jordan Bernick; Juan Russo; Zachary MacDonald; Christopher Glover; Alexander Dick; Munir Boodhwani; Buu-Khanh Lam; Marc Ruel; Marino Labinaz; Ian G Burwash
Journal:  PLoS One       Date:  2018-04-26       Impact factor: 3.240

8.  Bedside Renal Doppler Ultrasonography and Acute Kidney Injury after TAVR.

Authors:  Marilou Peillex; Benjamin Marchandot; Sophie Bayer; Eric Prinz; Kensuke Matsushita; Adrien Carmona; Joe Heger; Antonin Trimaille; Hélène Petit-Eisenmann; Laurence Jesel; Patrick Ohlmann; Olivier Morel
Journal:  J Clin Med       Date:  2020-03-25       Impact factor: 4.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.