Literature DB >> 22243414

Integrated lateral flow test strip with electrochemical sensor for quantification of phosphorylated cholinesterase: biomarker of exposure to organophosphorus agents.

Dan Du1, Jun Wang, Limin Wang, Donglai Lu, Yuehe Lin.   

Abstract

An integrated lateral flow test strip with an electrochemical sensor (LFTSES) device with rapid, selective, and sensitive response for quantification of exposure to organophosphorus (OP) pesticides and nerve agents has been developed. The principle of this approach is based on parallel measurements of postexposure and baseline acetylcholinesterase (AChE) enzyme activity, where reactivation of the phosphorylated AChE is exploited to enable measurement of the total amount of AChE (including inhibited and active) which is used as a baseline for calculation of AChE inhibition. Quantitative measurement of phosphorylated adduct (OP-AChE) was realized by subtracting the active AChE from the total amount of AChE. The proposed LFTSES device integrates immunochromatographic test strip technology with electrochemical measurement using a disposable screen printed electrode which is located under the test zone. It shows a linear response between AChE enzyme activity and enzyme concentration from 0.05 to 10 nM, with a detection limit of 0.02 nM. On the basis of this reactivation approach, the LFTSES device has been successfully applied for in vitro red blood cells inhibition studies using chlorpyrifos oxon as a model OP agent. This approach not only eliminates the difficulty in screening of low-dose OP exposure because of individual variation of normal AChE values but also avoids the problem in overlapping substrate specificity with cholinesterases and avoids potential interference from other electroactive species in biological samples. It is baseline free and thus provides a rapid, sensitive, selective, and inexpensive tool for in-field and point-of-care assessment of exposures to OP pesticides and nerve agents.
© 2011 American Chemical Society

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22243414     DOI: 10.1021/ac202391w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  12 in total

Review 1.  Paper-based assays for urine analysis.

Authors:  Eric Lepowsky; Fariba Ghaderinezhad; Stephanie Knowlton; Savas Tasoglu
Journal:  Biomicrofluidics       Date:  2017-10-17       Impact factor: 2.800

2.  Simultaneous detection of dual biomarkers from humans exposed to organophosphorus pesticides by combination of immunochromatographic test strip and ellman assay.

Authors:  Mingming Yang; Yuting Zhao; Limin Wang; Michael Paulsen; Christopher D Simpson; Fengquan Liu; Dan Du; Yuehe Lin
Journal:  Biosens Bioelectron       Date:  2017-12-21       Impact factor: 10.618

3.  Hybrid paper and 3D-printed microfluidic device for electrochemical detection of Ag nanoparticle labels.

Authors:  Charuksha Walgama; Michael P Nguyen; Lisa M Boatner; Ian Richards; Richard M Crooks
Journal:  Lab Chip       Date:  2020-05-05       Impact factor: 6.799

4.  Fluorine-free synthesis of Ti3C2 MQDs for smartphone-based fluorescent and colorimetric determination of acetylcholinesterase and organophosphorus pesticides.

Authors:  Ting Pei; Yu He; Yaping Wang; Gongwu Song
Journal:  Mikrochim Acta       Date:  2021-12-04       Impact factor: 5.833

5.  Magnetized carbon nanotubes for visual detection of proteins directly in whole blood.

Authors:  Yan Huang; Yongqiang Wen; Kwaku Baryeh; Sunitha Takalkar; Michelle Lund; Xueji Zhang; Guodong Liu
Journal:  Anal Chim Acta       Date:  2017-09-27       Impact factor: 6.558

6.  Calorimetric lateral flow immunoassay detection platform based on the photothermal effect of gold nanocages with high sensitivity, specificity, and accuracy.

Authors:  Xiaoyan Hu; Jiangshan Wan; Xiaole Peng; Hao Zhao; Dingwen Shi; Liyi Mai; Hai Yang; Yanbing Zhao; Xiangliang Yang
Journal:  Int J Nanomedicine       Date:  2019-09-20

7.  A 3D-Printed, Portable, Optical-Sensing Platform for Smartphones Capable of Detecting the Herbicide 2,4-Dichlorophenoxyacetic Acid.

Authors:  Yijia Wang; Mohamed M A Zeinhom; Mingming Yang; Rongrong Sun; Shengfu Wang; Jordan N Smith; Charles Timchalk; Lei Li; Yuehe Lin; Dan Du
Journal:  Anal Chem       Date:  2017-08-21       Impact factor: 6.986

Review 8.  Recent Advancements in Enzyme-Based Lateral Flow Immunoassays.

Authors:  Donato Calabria; Maria Maddalena Calabretta; Martina Zangheri; Elisa Marchegiani; Ilaria Trozzi; Massimo Guardigli; Elisa Michelini; Fabio Di Nardo; Laura Anfossi; Claudio Baggiani; Mara Mirasoli
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

9.  Integrated Lateral Flow Device for Flow Control with Blood Separation and Biosensing.

Authors:  Veronica Betancur; Jianbo Sun; Nianqiang Wu; Yuxin Liu
Journal:  Micromachines (Basel)       Date:  2017-12-20       Impact factor: 2.891

Review 10.  Enzyme-polymeric/inorganic metal oxide/hybrid nanoparticle bio-conjugates in the development of therapeutic and biosensing platforms.

Authors:  Suliman Khan; Mohammad Mahdi Nejadi Babadaei; Anwarul Hasan; Zehra Edis; Farnoosh Attar; Rabeea Siddique; Qian Bai; Majid Sharifi; Mojtaba Falahati
Journal:  J Adv Res       Date:  2021-02-04       Impact factor: 10.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.