Literature DB >> 22240271

Failure evaluation after a 6-year retention period: a comparison between glass fiber-reinforced (GFR) and multistranded bonded retainers.

Eugenio Bolla1, Mauro Cozzani, Tiziana Doldo, Mattia Fontana.   

Abstract

OBJECTIVES: The aim of this study was to compare bond failure and breakage rates of two types of bonded lingual orthodontic retainers (GFR and .0175" multistranded stainless steel wire [MST]) after a 6-year retention period. SUBJECTS AND METHODS: Eighty-five young adults were randomly divided into two groups: 40 subjects received 48 GFR retainers (14 maxillary and 34 mandibular retainers), and 45 subjects received 50 MST retainers (18 maxillary and 32 mandibular retainers). A Fisher's exact test was performed in order to identify significant differences in the percentage of detachment and breakage of the retainers between the groups.
RESULTS: The maxillary detachment rates were 21.42% for the GFR group and 22.22% for the MST group; the mandibular detachment rates were 11.76% for the GFR group and 15.62% for the MST group. The maxillary breakage rates were 7.14% for the GFR group and 16.66% for the MST group; the mandibular breakage rates were 8.82% for the GFR group and 15.62% for the MST group. The differences were not statistically significant.
CONCLUSION: GFR and multistranded stainless steel retainers showed similar results in terms of bond failure and breakage after 6 years of retention. The use of GFR retainers as a retention strategy should not be discouraged and could be considered a viable esthetic alternative to stainless steel wire retainers. Copyright Â
© 2011 CEO. Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22240271     DOI: 10.1016/j.ortho.2011.12.005

Source DB:  PubMed          Journal:  Int Orthod        ISSN: 1761-7727


  13 in total

1.  Survival of post-treatment canine-to-canine lingual retainers with fiber-reinforced composite resin: a retrospective study.

Authors:  Davide Farronato; Roberto Briguglio; Francesco Mangano; Lorenzo Azzi; Giovanni Battista Grossi; Francesco Briguglio
Journal:  Ann Stomatol (Roma)       Date:  2014-11-20

2.  Debate: short-term orthodontics.

Authors:  Anoop Maini; Rob Chate
Journal:  Br Dent J       Date:  2014-04       Impact factor: 1.626

3.  Orthodontic retention--three methods trialed.

Authors:  J Faith Cope; Thomas Lamont
Journal:  Evid Based Dent       Date:  2016-03

Review 4.  What causes failure of fixed orthodontic retention? - systematic review and meta-analysis of clinical studies.

Authors:  Maciej Jedliński; Katarzyna Grocholewicz; Marta Mazur; Joanna Janiszewska-Olszowska
Journal:  Head Face Med       Date:  2021-07-24       Impact factor: 2.151

5.  Fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro.

Authors:  Dave Lie Sam Foek; Enver Yetkiner; Mutlu Ozcan
Journal:  Korean J Orthod       Date:  2013-08-22       Impact factor: 1.372

6.  Clinical evaluation of bond failures and survival between mandibular canine-to-canine retainers made of flexible spiral wire and fiber-reinforced composite.

Authors:  Maria F Sfondrini; Danilo Fraticelli; Linda Castellazzi; Andrea Scribante; Paola Gandini
Journal:  J Clin Exp Dent       Date:  2014-04-01

7.  Two-year survival analysis of twisted wire fixed retainer versus spiral wire and fiber-reinforced composite retainers: a preliminary explorative single-blind randomized clinical trial.

Authors:  Farhad Sobouti; Vahid Rakhshan; Mahdi Gholamrezaei Saravi; Ali Zamanian; Mahsa Shariati
Journal:  Korean J Orthod       Date:  2016-03-18       Impact factor: 1.372

Review 8.  Retention procedures for stabilising tooth position after treatment with orthodontic braces.

Authors:  Simon J Littlewood; Declan T Millett; Bridget Doubleday; David R Bearn; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2016-01-29

9.  Evaluation of load-deflection properties of fiber-reinforced composites and its comparison with stainless steel wires.

Authors:  Shiva Alavi; Tayebe Mamavi
Journal:  Dent Res J (Isfahan)       Date:  2014-03

Review 10.  In vivo orthodontic retainer survival - a review.

Authors:  Anca Victoria Labunet; Mîndra Badea
Journal:  Clujul Med       Date:  2015-07-01
View more