Stephanie C von Plocki1, David Armbruster, Karina Klein, Käthi Kämpf, Katalin Zlinszky, Monika Hilbe, Peter Kronen, Elliott Gruskin, Brigitte von Rechenberg.
Abstract
OBJECTIVE: To evaluate biocompatibility of biodegradable sleeves containing antimicrobial agents, designed for local drug delivery to prevent implant-related infection. STUDY
DESIGN: Synthetic polyester sleeves (a copolymer of glycolide, caprolactone, trimethylene carbonate, lactide) were cast as thin films. The antimicrobial agents incorporated in the sleeves included gentamicin sulfate, triclosan, or a combination of these drugs. ANIMALS: Adult sheep (n = 15).
METHODS: Two limited contact dynamic compression plates (LC-DCP) with or without sleeves were implanted on tibiae (bilateral) of 15 sheep. Sleeves were placed over the plates before implantation. Beneath half of the plates, 5-mm drill hole defects were made in the near cortex. Samples were harvested 4 weeks later for histology and microradiography.
RESULTS: Macroscopically, no irritation of bone or adjacent tissue was seen. Small remnants of sleeves were visible on histology, and positively correlated with the presence of macrophages and foreign body cells. Thick sections showed no difference between the test samples and controls in terms of fibrous capsule formation, periosteal remodeling, and defect remodeling. Inflammatory cells, macrophages, and foreign body cells were more prominent in sections with sleeves, but were not statistically significantly different from controls. Cell numbers were within normal physiologic limits normally seen as cellular response to foreign bodies consisting of polymers.
CONCLUSION: The normal healing response indicated that the biodegradable sleeves demonstrate tissue biocompatibility. © Copyright 2012 by The American College of Veterinary Surgeons.
OBJECTIVE: To evaluate biocompatibility of biodegradable sleeves containing antimicrobial agents, designed for local drug delivery to prevent implant-related infection. STUDY
DESIGN: Synthetic polyester sleeves (a copolymer of glycolide, caprolactone, trimethylene carbonate, lactide) were cast as thin films. The antimicrobial agents incorporated in the sleeves included gentamicin sulfate, triclosan, or a combination of these drugs. ANIMALS: Adult sheep (n = 15).
METHODS: Two limited contact dynamic compression plates (LC-DCP) with or without sleeves were implanted on tibiae (bilateral) of 15 sheep. Sleeves were placed over the plates before implantation. Beneath half of the plates, 5-mm drill hole defects were made in the near cortex. Samples were harvested 4 weeks later for histology and microradiography.
RESULTS: Macroscopically, no irritation of bone or adjacent tissue was seen. Small remnants of sleeves were visible on histology, and positively correlated with the presence of macrophages and foreign body cells. Thick sections showed no difference between the test samples and controls in terms of fibrous capsule formation, periosteal remodeling, and defect remodeling. Inflammatory cells, macrophages, and foreign body cells were more prominent in sections with sleeves, but were not statistically significantly different from controls. Cell numbers were within normal physiologic limits normally seen as cellular response to foreign bodies consisting of polymers.
CONCLUSION: The normal healing response indicated that the biodegradable sleeves demonstrate tissue biocompatibility. © Copyright 2012 by The American College of Veterinary Surgeons.
Entities:
Mesh:
Substances:
Year: 2012
PMID: 22239648 DOI: 10.1111/j.1532-950X.2011.00943.x
Source DB: PubMed Journal: Vet Surg ISSN: 0161-3499 Impact factor: 1.495