Repeatability of color-measuring devices.

Karl Martin Lehmann1, Alessandro Devigus, Christopher Igiel, Stefan Wentaschek, Mehdi Sattari Azar, Herbert Scheller.   

Abstract

INTRODUCTION: The objective of this study was to evaluate the intra- and interdevice repeatability in different tooth regions using three color-measuring devices under clinical conditions.
MATERIALS AND METHODS: Fifteen shade measurements (cervical, body, incisal) were recorded on 15 patients by one investigator using three color-measuring devices (VITA Easyshade compact, DeguDent Shadepilot, X-Rite ShadeVision). CIE Lab values were determined for all maxillary anterior teeth. Intraclass correlation coefficients (ICCs) were used to statistically analyze intra-and inter-device repeatability for different tooth regions. Color differences (ΔE) between measurements were also computed to evaluate the clinical acceptability of repeatability values. The data were evaluated using analysis of variance and Bonferroni's adjustment to control for multiple testing. Differences were deemed significant when P < 0.016.
RESULTS: The three color-measuring devices generally exhibited high repeatability of color coordinates for all tooth regions (ICC > 0.516-0.986, ΔE < 3.03). In contrast, inter-device repeatability was lower for all tooth regions (ICC = 0.010-0.922, ΔE = 4.06-16.04).
CONCLUSIONS: High intra-device repeatability of color coordinates could be achieved for all tooth regions when the same color-measuring device was used. However, because of low inter-device repeatability, results using different color-measuring devices are not comparable.

Entities:  

Mesh:

Year:  2011        PMID: 22238725

Source DB:  PubMed          Journal:  Eur J Esthet Dent        ISSN: 1862-0612


  6 in total

1.  Influence of Light Conditions and Light Sources on Clinical Measurement of Natural Teeth Color using VITA Easyshade Advance 4,0® Spectrophotometer. Pilot Study.

Authors:  Ivona Posavec; Vladimir Prpić; Dubravka Knezović Zlatarić
Journal:  Acta Stomatol Croat       Date:  2016-12

2.  In Vivo Evaluations of Inter-Observer Reliability Using VITA Easyshade® Advance 4.0 Dental Shade-Matching Device.

Authors:  Dubravka Knezović; Davor Zlatarić; Iva Ž Illeš; Maja Alajbeg
Journal:  Acta Stomatol Croat       Date:  2016-03

3.  In Vivo and in Vitro Evaluations of Repeatability and Accuracy of VITA Easyshade® Advance 4.0 Dental Shade-Matching Device.

Authors:  Dubravka Knezović; Davor Zlatarić; Iva Ž Illeš; Maja Alajbeg
Journal:  Acta Stomatol Croat       Date:  2015-06

4.  The reproducibility of electronic color measurements of the marginal gingiva.

Authors:  Henning Staedt; Eva Mally; Herbert Scheller; Stefan Wentaschek; Peer Wolfgang Kämmerer; Adrian Kasaj; Alessandro Devigus; Karl Martin Lehmann
Journal:  Clin Oral Investig       Date:  2020-06-22       Impact factor: 3.573

5.  Repeatability of dental shade by digital spectrophotometry in current, former, and never smokers.

Authors:  Gianluca Conte; Sebastiano Antonio Pacino; Salvatore Urso; Rosalia Emma; Eugenio Pedullà; Fabio Cibella; Martina Stefanini; Giovanni Zucchelli; Riccardo Polosa
Journal:  Odontology       Date:  2022-03-10       Impact factor: 2.885

6.  Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study.

Authors:  Hee-Kyung Kim
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.