Literature DB >> 22237489

Inhibition of neointimal proliferation after bare metal stent implantation with low-pressure drug delivery using a paclitaxel-coated balloon in porcine coronary arteries.

Bodo Cremers, Bettina Kelsch, Yvonne P Clever, Neil Hattangadi, Dirk Mahnkopf, Ulrich Speck, Matthias Taupitz, Bruno Scheller.   

Abstract

A variety of mechanical and laser-based methods remove or shift atherosclerotic plaques and reopen the artery to its original lumen. Subsequent treatment with drug-coated balloons (DCB) may smooth the vessel wall but does not require high-pressure inflation. We investigated the efficacy of paclitaxel-coated balloons inflated with only 2 atm after bare metal stent implantation in coronary arteries of 24 pigs. Angiography and histomorphometry was performed on day 28. DCB inflated with 2 atm caused similar reduction of late lumen loss (LLL) as high-pressure inflation with 12 atm (0.89 ± 0.58 vs. 0.72 ± 0.39 mm, p = 0.34). Both DCB treatments significantly (p < 0.01) reduced LLL versus uncoated balloons (1.50 ± 0.51 mm). Treatment with low-pressure DCB resulted in less maximal intimal thickness (0.45 ± 0.15 vs. 0.67 ± 0.25 mm) and neointimal area (2.93 ± 0.73 vs. 3.82 ± 1.27 mm(2)) than treatment with uncoated balloons (p < 0.05). In conclusion, low-pressure treatment with DCB was similarly effective as high-pressure treatment justifying clinical trials in vessels which will benefit from inhibition of neointimal proliferation but may not tolerate high inflation pressure.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22237489     DOI: 10.1007/s00392-011-0408-y

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  21 in total

Review 1.  Drug-coated balloons for the prevention of vascular restenosis.

Authors:  William A Gray; Juan F Granada
Journal:  Circulation       Date:  2010-06-22       Impact factor: 29.690

2.  Treatment of coronary in-stent restenosis with a paclitaxel-coated balloon catheter.

Authors:  Bruno Scheller; Christoph Hehrlein; Wolfgang Bocksch; Wolfgang Rutsch; Dariush Haghi; Ulrich Dietz; Michael Böhm; Ulrich Speck
Journal:  N Engl J Med       Date:  2006-11-13       Impact factor: 91.245

3.  Catheter-based delivery of fluid paclitaxel for prevention of restenosis in native coronary artery lesions after stent implantation.

Authors:  Christian Herdeg; Katrin Göhring-Frischholz; Karl K Haase; Tobias Geisler; Christine Zürn; Ulrike Hartmann; Jochen Wöhrle; Thorsten Nusser; Jürgen Dippon; Andreas E May; Meinrad Gawaz
Journal:  Circ Cardiovasc Interv       Date:  2009-07-22       Impact factor: 6.546

Review 4.  Preclinical models of restenosis and their application in the evaluation of drug-eluting stent systems.

Authors:  L E Leigh Perkins
Journal:  Vet Pathol       Date:  2010-01       Impact factor: 2.221

Review 5.  Summary of NICE guidance.

Authors:  Sebastian Sixt; Thomas Zeller
Journal:  Heart       Date:  2011-07-18       Impact factor: 5.994

Review 6.  The utility of animal models in the preclinical study of interventions to prevent human coronary artery restenosis: analysis and recommendations. On behalf of the Subcommittee on Animal, Cellular and Molecular Models of Thrombosis and Haemostasis of the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis.

Authors:  G J Johnson; T R Griggs; L Badimon
Journal:  Thromb Haemost       Date:  1999-05       Impact factor: 5.249

7.  In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia.

Authors:  R Kornowski; M K Hong; F O Tio; O Bramwell; H Wu; M B Leon
Journal:  J Am Coll Cardiol       Date:  1998-01       Impact factor: 24.094

8.  Sirolimus-eluting stents vs paclitaxel-eluting stents in patients with coronary artery disease: meta-analysis of randomized trials.

Authors:  Adnan Kastrati; Alban Dibra; Sonja Eberle; Julinda Mehilli; José Suárez de Lezo; Jean-Jacque Goy; Kurt Ulm; Albert Schömig
Journal:  JAMA       Date:  2005-08-17       Impact factor: 56.272

Review 9.  Current status of rotational atherectomy.

Authors:  Erdal Cavusoglu; Annapoorna S Kini; Jonathan D Marmur; Samin K Sharma
Journal:  Catheter Cardiovasc Interv       Date:  2004-08       Impact factor: 2.692

10.  Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis.

Authors:  Bruno Scheller; Ulrich Speck; Claudia Abramjuk; Ulrich Bernhardt; Michael Böhm; Georg Nickenig
Journal:  Circulation       Date:  2004-08-09       Impact factor: 29.690

View more
  6 in total

Review 1.  Pathogenesis of Systemic Sclerosis.

Authors:  Debendra Pattanaik; Monica Brown; Bradley C Postlethwaite; Arnold E Postlethwaite
Journal:  Front Immunol       Date:  2015-06-08       Impact factor: 7.561

2.  Local paclitaxel induces late lumen enlargement in coronary arteries after balloon angioplasty.

Authors:  Franz X Kleber; Antonia Schulz; Matthias Waliszewski; Telse Hauschild; Michael Böhm; Ulrich Dietz; Bodo Cremers; Bruno Scheller; Yvonne P Clever
Journal:  Clin Res Cardiol       Date:  2014-10-28       Impact factor: 5.460

3.  The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model.

Authors:  D Ley; R Mühl-Benninghaus; U Yilmaz; H Körner; G F M Cattaneo; W Mailänder; Y-J Kim; B Scheller; W Reith; A Simgen
Journal:  Clin Neuroradiol       Date:  2015-12-23       Impact factor: 3.649

4.  Treatment of coronary de novo bifurcation lesions with DCB only strategy.

Authors:  Antonia Schulz; Telse Hauschild; Franz X Kleber
Journal:  Clin Res Cardiol       Date:  2014-02-14       Impact factor: 5.460

5.  Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T.

Authors:  Andreas Simgen; Désirée Ley; Christian Roth; Giorgio Franco Maria Cattaneo; Ruben Mühl-Benninghaus; Andreas Müller; Heiko Körner; Yoo-Jin Kim; Bruno Scheller; Wolfgang Reith; Umut Yilmaz
Journal:  Neuroradiology       Date:  2016-07-25       Impact factor: 2.804

6.  Evaluation of a newly designed flow diverter for the treatment of intracranial aneurysms in an elastase-induced aneurysm model, in New Zealand white rabbits.

Authors:  Andreas Simgen; Desiree Ley; Christian Roth; Umut Yilmaz; Heiko Körner; Ruben Mühl-Benninghaus; Yoo-Jin Kim; Bruno Scheller; Wolfgang Reith
Journal:  Neuroradiology       Date:  2014-02       Impact factor: 2.804

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.