Literature DB >> 22236703

Improved radiograph measurement inter-observer reliability by use of statistical shape models.

E C Pegg1, S J Mellon, G Salmon, A Alvand, H Pandit, D W Murray, H S Gill.   

Abstract

Pre- and post-operative radiographs of patients undergoing joint arthroplasty are often examined for a variety of purposes including preoperative planning and patient assessment. This work examines the feasibility of using active shape models (ASM) to semi-automate measurements from post-operative radiographs for the specific case of the Oxford™ Unicompartmental Knee. Measurements of the proximal tibia and the position of the tibial tray were made using the ASM model and manually. Data were obtained by four observers and one observer took four sets of measurements to allow assessment of the inter- and intra-observer reliability, respectively. The parameters measured were the tibial tray angle, the tray overhang, the tray size, the sagittal cut position, the resection level and the tibial width. Results demonstrated improved reliability (average of 27% and 11.2% increase for intra- and inter-reliability, respectively) and equivalent accuracy (p>0.05 for compared data values) for all of the measurements using the ASM model, with the exception of the tray overhang (p=0.0001). Less time (15s) was required to take measurements using the ASM model compared with manual measurements, which was significant. These encouraging results indicate that semi-automated measurement techniques could improve the reliability of radiographic measurements.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22236703     DOI: 10.1016/j.ejrad.2011.12.018

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  3 in total

1.  A semi-automated measurement technique for the assessment of radiolucency.

Authors:  E C Pegg; B J L Kendrick; H G Pandit; H S Gill; D W Murray
Journal:  J R Soc Interface       Date:  2014-04-23       Impact factor: 4.118

2.  Increasing shape modelling accuracy by adjusting for subject positioning: an application to the analysis of radiographic proximal femur symmetry using data from the Osteoarthritis Initiative.

Authors:  C Lindner; G A Wallis; T F Cootes
Journal:  Bone       Date:  2014-01-14       Impact factor: 4.398

3.  A Study on the Influence of Multi-Teaching Strategy Intervention Program on College Students' Absorptive Capacity and Employability.

Authors:  Michael Yao-Ping Peng; Lin Wang; Xiaoyao Yue; Yan Xu; Yongjun Feng
Journal:  Front Psychol       Date:  2021-03-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.