Literature DB >> 22235233

On the Feasibility of Verification of 3D Dosimetry Near Brachytherapy Sources Using PRESAGE/Optical-CT.

M Pierquet1, O Craciunescu, B Steffey, H Song, M Oldham.   

Abstract

PURPOSE: The feasibility of using the PRESAGE/Optical-CT system for 3D dosimetry verification around a brachytherapy source is investigated. METHOD AND MATERIALS: Brachytherapy dose distributions were obtained by irradiation of cylindrical PRESAGE volumes 6cm in diameter by 8cm height with a GammaMed 12i Ir-192 HDR unit (Varian Medical Systems). A narrow channel on the central axis was created by setting a steel catheter in the Presage during manufacture, enabling measurements close to the source (~3mm).
RESULTS: Comparison of dose line profiles shows good agreement between PRESAGE and verified calculated dose calculation, in both high and low dose regions.
CONCLUSION: The PRESAGE/Optical-CT shows good potential in verification of 3D dose distributions around brachytherapy sources.

Entities:  

Year:  2010        PMID: 22235233      PMCID: PMC3253376          DOI: 10.1088/1742-6596/250/1/012091

Source DB:  PubMed          Journal:  J Phys Conf Ser        ISSN: 1742-6588


  11 in total

1.  Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.

Authors:  F Ballester; V Puchades; J L Lluch; M A Serrano-Andrés; Y Limami; J Pérez-Calatayud; E Casal
Journal:  Med Phys       Date:  2001-12       Impact factor: 4.071

2.  CERR: a computational environment for radiotherapy research.

Authors:  Joseph O Deasy; Angel I Blanco; Vanessa H Clark
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

3.  Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.

Authors:  Mark J Rivard; Bert M Coursey; Larry A DeWerd; William F Hanson; M Saiful Huq; Geoffrey S Ibbott; Michael G Mitch; Ravinder Nath; Jeffrey F Williamson
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

4.  Characterisation of PRESAGE: A new 3-D radiochromic solid polymer dosemeter for ionising radiation.

Authors:  J Adamovics; M J Maryanski
Journal:  Radiat Prot Dosimetry       Date:  2006-06-17       Impact factor: 0.972

5.  A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system.

Authors:  H S Sakhalkar; J Adamovics; G Ibbott; M Oldham
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Three-dimensional dosimetry in brachytherapy: A MAGAT study.

Authors:  Min-Hsing Lin; Tzung-Chi Huang; Ming-Jen Kao; Jay Wu; Chia-Lin Chen; Tung-Hsin Wu
Journal:  Appl Radiat Isot       Date:  2009-02-26       Impact factor: 1.513

7.  Dosimetric characterization of a 131Cs brachytherapy source by thermoluminescence dosimetry in liquid water.

Authors:  Ramesh Tailor; Geoffrey Ibbott; Stephanie Lampe; Whitney Bivens Warren; Naresh Tolani
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  Dosimetry of interstitial brachytherapy sources: recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. American Association of Physicists in Medicine.

Authors:  R Nath; L L Anderson; G Luxton; K A Weaver; J F Williamson; A S Meigooni
Journal:  Med Phys       Date:  1995-02       Impact factor: 4.071

Review 9.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

10.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

View more
  4 in total

1.  An investigation of a PRESAGE® in vivo dosimeter for brachytherapy.

Authors:  A K Vidovic; T Juang; S Meltsner; J Adamovics; J Chino; B Steffey; O Craciunescu; M Oldham
Journal:  Phys Med Biol       Date:  2014-06-24       Impact factor: 3.609

2.  On the feasibility of polyurethane based 3D dosimeters with optical CT for dosimetric verification of low energy photon brachytherapy seeds.

Authors:  Justus Adamson; Yun Yang; Titania Juang; Kelsey Chisholm; Leith Rankine; John Adamovics; Fang Fang Yin; Mark Oldham
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

3.  Commissioning a CT-compatible LDR tandem and ovoid applicator using Monte Carlo calculation and 3D dosimetry.

Authors:  Justus Adamson; Joseph Newton; Yun Yang; Beverly Steffey; Jing Cai; John Adamovics; Mark Oldham; Junzo Chino; Oana Craciunescu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

4.  Towards comprehensive characterization of Cs-137 Seeds using PRESAGE® dosimetry with optical tomography.

Authors:  J Adamson; Y Yang; L Rankine; J Newton; J Adamovics; O Craciunescu; M Oldham
Journal:  J Phys Conf Ser       Date:  2013
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.