Literature DB >> 22231173

Use of expiratory change in bladder pressure to assess expiratory muscle activity in patients with large respiratory excursions in central venous pressure.

James W Leatherman1, Christina Bastin-Dejong, Robert S Shapiro, Ramiro Saavedra-Romero.   

Abstract

BACKGROUND: Expiratory muscle activity may cause the end-expiratory central venous pressure (CVP) to greatly overestimate right atrial transmural pressure.
METHODS: We recorded CVP and expiratory change in intra-abdominal pressure (ΔIAP) in 39 patients who had a respiratory excursion in CVP from end-expiration to end-inspiration (CVP(ee)-CVP(ei)) ≥ 8 mmHg. Uncorrected CVP was measured at end-expiration, and corrected CVP was calculated as uncorrected CVP-ΔIAP. In 13 patients measurements were repeated during relaxed breathing.
RESULTS: The CVP(ee)-CVP(ei) was 15.2 ± 6.3 mmHg (range 8-34 mmHg), and ΔIAP was 7.4 ± 6.0 mmHg (range 0-30 mmHg). Uncorrected CVP was 18.3 ± 6.1 mmHg, and corrected CVP was 10.9 ± 3.9 mmHg. There was a significant positive correlation between CVP(ee)-CVP(ei) and ΔIAP (r = 0.814). However, some patients with a large CVP(ee)-CVP(ei) had negligible ΔIAP. In a subset of 13 patients with active expiration who had a relaxed CVP tracing available for comparison, the difference between uncorrected CVP and relaxed CVP was much greater than the difference between corrected CVP and relaxed CVP (7.3 ± 3.0 vs. 1.1 ± 0.7 mmHg, p < 0.001).
CONCLUSION: Patients with large respiratory excursions in CVP often have significant expiratory muscle activity that will cause their CVP to overestimate transmural right atrial pressure. The magnitude of expiratory muscle activity can be assessed by measuring ΔIAP. Subtracting ΔIAP from the end-expiratory CVP usually provides a reasonable estimate of the CVP that would be obtained if exhalation were passive.

Entities:  

Mesh:

Year:  2012        PMID: 22231173     DOI: 10.1007/s00134-011-2450-7

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  18 in total

Review 1.  Central venous pressure: A useful but not so simple measurement.

Authors:  Sheldon Magder
Journal:  Crit Care Med       Date:  2006-08       Impact factor: 7.598

2.  Central venous pressure monitoring.

Authors:  Sheldon Magder
Journal:  Curr Opin Crit Care       Date:  2006-06       Impact factor: 3.687

3.  The clinical role of central venous pressure measurements.

Authors:  Sheldon Magder; Fahad Bafaqeeh
Journal:  J Intensive Care Med       Date:  2007 Jan-Feb       Impact factor: 3.510

4.  Interpretation of the pulmonary artery occlusion pressure in mechanically ventilated patients with large respiratory excursions in intrathoracic pressure.

Authors:  J D Hoyt; J W Leatherman
Journal:  Intensive Care Med       Date:  1997-11       Impact factor: 17.440

5.  Hyperpnea limits the volume recruited by positive end-expiratory pressure.

Authors:  A Chandra; J W Coggeshall; S A Ravenscraft; J J Marini
Journal:  Am J Respir Crit Care Med       Date:  1994-10       Impact factor: 21.405

6.  Exercise-induced abdominal muscle fatigue in healthy humans.

Authors:  Bryan J Taylor; Stephen C How; Lee M Romer
Journal:  J Appl Physiol (1985)       Date:  2006-01-19

7.  Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge.

Authors:  David Osman; Christophe Ridel; Patrick Ray; Xavier Monnet; Nadia Anguel; Christian Richard; Jean-Louis Teboul
Journal:  Crit Care Med       Date:  2007-01       Impact factor: 7.598

8.  Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects.

Authors:  Anand Kumar; Ramon Anel; Eugene Bunnell; Kalim Habet; Sergio Zanotti; Stephanie Marshall; Alex Neumann; Amjad Ali; Mary Cheang; Clifford Kavinsky; Joseph E Parrillo
Journal:  Crit Care Med       Date:  2004-03       Impact factor: 7.598

9.  Use of bladder pressure to correct for the effect of expiratory muscle activity on central venous pressure.

Authors:  Ahmad S Qureshi; Robert S Shapiro; James W Leatherman
Journal:  Intensive Care Med       Date:  2007-09-01       Impact factor: 17.440

Review 10.  Bench-to-bedside review: ventilatory abnormalities in sepsis.

Authors:  Sheldon Magder
Journal:  Crit Care       Date:  2009-01-15       Impact factor: 9.097

View more
  1 in total

1.  Year in review in Intensive Care Medicine 2012. II: Pneumonia and infection, sepsis, coagulation, hemodynamics, cardiovascular and microcirculation, critical care organization, imaging, ethics and legal issues.

Authors:  Massimo Antonelli; Marc Bonten; Maurizio Cecconi; Jean Chastre; Giuseppe Citerio; Giorgio Conti; J Randall Curtis; Goran Hedenstierna; Michael Joannidis; Duncan Macrae; Salvatore M Maggiore; Jordi Mancebo; Alexandre Mebazaa; Jean-Charles Preiser; Patricia Rocco; Jean-François Timsit; Jan Wernerman; Haibo Zhang
Journal:  Intensive Care Med       Date:  2013-01-05       Impact factor: 17.440

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.