Literature DB >> 22230131

Mapping of superficial extremity veins: normal diameters and trends in a vascular patient-population.

Dan E Spivack1, Patrick Kelly, John P Gaughan, Paul S van Bemmelen.   

Abstract

Ultrasonic measurement of superficial extremity veins is a common procedure. To establish normal values for vein-size in a population of vascular patients and to assess if measurements remain unchanged over time, we analyzed a database with results of 28,130 measurements in 2420 separate saphenous and 3206 cephalic veins. Mean size of the great saphenous vein ranges from 2.3 mm to 4.4 mm but did not follow a tapering pattern as is often assumed. The distal calf segment is smaller than the ankle segment. The mean cephalic vein size in the upper arm (2.4 mm) was smaller than at the antecubital level (2.7 mm). A decrease in vein diameter over time was noted in many locations and this reached statistical significance (p < 0.005 for the thigh segment). The clinical significance of this is a need to repeat ultrasonic vein-mapping if more than a year elapses between ultrasound and surgical vein harvest.
Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22230131     DOI: 10.1016/j.ultrasmedbio.2011.11.008

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  An intravascular magnetic wire for the high-throughput retrieval of circulating tumour cells in vivo.

Authors:  Ophir Vermesh; Amin Aalipour; T Jessie Ge; Yamil Saenz; Yue Guo; Israt S Alam; Seung-Min Park; Charlie N Adelson; Yoshiaki Mitsutake; Jose Vilches-Moure; Elias Godoy; Michael H Bachmann; Chin Chun Ooi; Jennifer K Lyons; Kerstin Mueller; Hamed Arami; Alfredo Green; Edward I Solomon; Shan X Wang; Sanjiv S Gambhir
Journal:  Nat Biomed Eng       Date:  2018-07-16       Impact factor: 25.671

Review 2.  Intimal Hyperplasia and Arteriovenous Fistula Failure: Looking Beyond Size Differences.

Authors:  Roberto I Vazquez-Padron; Juan C Duque; Marwan Tabbara; Loay H Salman; Laisel Martinez
Journal:  Kidney360       Date:  2021-08

3.  A fiber optic photoacoustic sensor for real-time heparin monitoring.

Authors:  Jingcheng Zhou; Wonjun Yim; Jiajing Zhou; Zhicheng Jin; Ming Xu; Yash Mantri; Tengyu He; Yong Cheng; Lei Fu; Zhuohong Wu; Tiffany Hancock; William Penny; Jesse V Jokerst
Journal:  Biosens Bioelectron       Date:  2021-10-06       Impact factor: 12.545

4.  The effect of pathologic venous valve on neighboring valves: fluid-structure interactions modeling.

Authors:  Elina Soifer; Dar Weiss; Gil Marom; Shmuel Einav
Journal:  Med Biol Eng Comput       Date:  2016-09-23       Impact factor: 2.602

5.  Verification of a Novel Minimally Invasive Device for the Isolation of Rare Circulating Tumor Cells (CTC) in Cancer Patients' Blood.

Authors:  Paul Friedrich Geus; Felix Hehnen; Sophia Krakowski; Klaus Lücke; Dave S B Hoon; Nikolaj Frost; Ulrich Kertzscher; Gabi Wendt
Journal:  Cancers (Basel)       Date:  2022-09-29       Impact factor: 6.575

6.  Placement of vena cava filter via percutaneous puncture of the great saphenous vein.

Authors:  Yiqi Jin; Dayong Zhou; Lei Chen; Xianchen Huang; Guoxiong Xu; Jian Huang; Liming Shen
Journal:  Exp Ther Med       Date:  2013-06-14       Impact factor: 2.447

7.  Distal end side-to-side anastomoses of sequential vein graft to small target coronary arteries improve intraoperative graft flow.

Authors:  Haitao Li; Baodong Xie; Chengxiong Gu; Mingxin Gao; Fan Zhang; Jiayang Wang; Longsheng Dai; Yang Yu
Journal:  BMC Cardiovasc Disord       Date:  2014-05-09       Impact factor: 2.298

8.  Co-Culture of Primary Human Coronary Artery and Internal Thoracic Artery Endothelial Cells Results in Mutually Beneficial Paracrine Interactions.

Authors:  Daria Shishkova; Victoria Markova; Maxim Sinitsky; Anna Tsepokina; Alexey Frolov; Nikita Zagorodnikov; Leo Bogdanov; Anton Kutikhin
Journal:  Int J Mol Sci       Date:  2020-10-28       Impact factor: 5.923

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.