Literature DB >> 22229109

Metal MEMS Tools for Beating-heart Tissue Approximation.

Evan J Butler1, Chris Folk, Adam Cohen, Nikolay V Vasilyev, Rich Chen, Pedro J Del Nido, Pierre E Dupont.   

Abstract

Achieving superior outcomes through the use of robots in medical applications requires an integrated approach to the design of the robot, tooling and the procedure itself. In this paper, this approach is applied to develop a robotic technique for closing abnormal communication between the atria of the heart. The goal is to achieve the efficacy of surgical closure as performed on a stopped, open heart with the reduced risk and trauma of a beating-heart catheter-based procedure. In the proposed approach, a concentric tube robot is used to percutaneously access the right atrium and deploy a tissue approximation device. The device is constructed using a metal MEMS fabrication process and is designed to both fit the manipulation capabilities of the robot as well as to reproduce the beneficial features of surgical closure by suture. Experimental results demonstrate device efficacy through manual in-vivo deployment and bench-top robotic deployment.

Entities:  

Year:  2011        PMID: 22229109      PMCID: PMC3252216          DOI: 10.1109/ICRA.2011.5980215

Source DB:  PubMed          Journal:  IEEE Int Conf Robot Autom        ISSN: 2154-8080


  9 in total

1.  Quasistatic Modeling of Concentric Tube Robots with External Loads.

Authors:  Jesse Lock; Genevieve Laing; Mohsen Mahvash; Pierre E Dupont
Journal:  Rep U S       Date:  2010-12-03

2.  A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots.

Authors:  D Caleb Rucker; Bryan A Jones; Robert J Webster
Journal:  IEEE Trans Robot       Date:  2010       Impact factor: 5.567

3.  Equilibrium Conformations of Concentric-tube Continuum Robots.

Authors:  D Caleb Rucker; Robert J Webster; Gregory S Chirikjian; Noah J Cowan
Journal:  Int J Rob Res       Date:  2010-09-01       Impact factor: 4.703

4.  Three-dimensional echo-guided beating heart surgery without cardiopulmonary bypass: atrial septal defect closure in a swine model.

Authors:  Yoshihiro Suematsu; Joseph F Martinez; Benjamin K Wolf; Gerald R Marx; Jeffrey A Stoll; Pierre E DuPont; Robert D Howe; John K Triedman; Pedro J del Nido
Journal:  J Thorac Cardiovasc Surg       Date:  2005-10-13       Impact factor: 5.209

5.  Design and Control of Concentric-Tube Robots.

Authors:  Pierre E Dupont; Jesse Lock; Brandon Itkowitz; Evan Butler
Journal:  IEEE Trans Robot       Date:  2010-04-01       Impact factor: 5.567

6.  Real-time Position Control of Concentric Tube Robots.

Authors:  Pierre E Dupont; Jesse Lock; Brandon Itkowitz
Journal:  IEEE Int Conf Robot Autom       Date:  2010-05-03

7.  Design and Integration of a Telerobotic System for Minimally Invasive Surgery of the Throat.

Authors:  Nabil Simaan; Kai Xu; Ankur Kapoor; Wei Wei; Peter Kazanzides; Paul Flint; Russell Taylor
Journal:  Int J Rob Res       Date:  2009-09-01       Impact factor: 4.703

Review 8.  Percutaneous closure of patent foramen ovale: a case series and literature review.

Authors:  Ravi K Mareedu; Milind S Shah; Juan E Mesa; Charles S McCauley
Journal:  Clin Med Res       Date:  2007-12-17

9.  Stiffness Control of Surgical Continuum Manipulators.

Authors:  Mohsen Mahvash; Pierre E Dupont
Journal:  IEEE Trans Robot       Date:  2011-04       Impact factor: 5.567

  9 in total
  7 in total

Review 1.  Robotics and imaging in congenital heart surgery.

Authors:  Nikolay V Vasilyev; Pierre E Dupont; Pedro J del Nido
Journal:  Future Cardiol       Date:  2012-03

Review 2.  Design Aspects of Additive Manufacturing at Microscale: A Review.

Authors:  Nikolaos Rogkas; Christos Vakouftsis; Vasilios Spitas; Nikos D Lagaros; Stelios K Georgantzinos
Journal:  Micromachines (Basel)       Date:  2022-05-15       Impact factor: 3.523

3.  Metal MEMS Tools for Beating-heart Tissue Removal.

Authors:  Andrew H Gosline; Nikolay V Vasilyev; Arun Veeramani; Mingting Wu; Greg Schmitz; Rich Chen; Veaceslav Arabagi; Pedro J Del Nido; Pierre E Dupont
Journal:  IEEE Int Conf Robot Autom       Date:  2012

4.  A Telerobotic System for Transnasal Surgery.

Authors:  Jessica Burgner; D Caleb Rucker; Hunter B Gilbert; Philip J Swaney; Paul T Russell; Kyle D Weaver; Robert J Webster
Journal:  IEEE ASME Trans Mechatron       Date:  2013-06-19       Impact factor: 5.303

5.  Percutaneous steerable robotic tool delivery platform and metal microelectromechanical systems device for tissue manipulation and approximation: closure of patent foramen ovale in an animal model.

Authors:  Nikolay V Vasilyev; Andrew H Gosline; Evan Butler; Nora Lang; Patrick J Codd; Haruo Yamauchi; Eric N Feins; Chris R Folk; Adam L Cohen; Richard Chen; David Zurakowski; Pedro J del Nido; Pierre E Dupont
Journal:  Circ Cardiovasc Interv       Date:  2013-07-30       Impact factor: 6.546

6.  Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools.

Authors:  Andrew H Gosline; Nikolay V Vasilyev; Evan J Butler; Chris Folk; Adam Cohen; Rich Chen; Nora Lang; Pedro J Del Nido; Pierre E Dupont
Journal:  Int J Rob Res       Date:  2012-08-01       Impact factor: 4.703

7.  New technologies for surgery of the congenital cardiac defect.

Authors:  David Kalfa; Emile Bacha
Journal:  Rambam Maimonides Med J       Date:  2013-07-25
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.