Literature DB >> 22227124

Wave intensity analysis of para-aortic counterpulsation.

Pong-Jeu Lu1, Chi-Fu Jeffrey Yang, Meng-Yu Wu, Chun-Hao Hung, Ming-Yao Chan, Tzu-Cheng Hsu.   

Abstract

Wave intensity analysis (WIA) was used to delineate and maximize the efficacy of a newly developed para-aortic blood pump (PABP). The intra-aortic balloon pump (IABP) was employed as the comparison benchmark. Acute porcine experiments using eight pigs, randomly divided into IABP (n = 4) and PABP (n = 4) groups, were conducted to compare the characteristics of intra- and para-aortic counterpulsation. We measured pressure and velocity with probes installed in the left anterior descending coronary artery and aorta, during and without PABP assistance. Wave intensity for aortic and left coronary waves were derived from pressure and flow measurements with synchronization correction applied. To achieve maximized support efficacy, deflation timings ranging from 25 ms ahead of to 35 ms after the R-wave were tested. Similar to those associated with IABP counterpulsation, the PABP-generated backward-traveling waves predominantly drove aortic and coronary blood flows. However, in contrast with IABP counterpulsation, the nonocclusive nature of the PABP allowed systolic unloading to be delayed into early systole, which resulted in near elimination of coronary blood steal without diminution of systolic left ventricular ejection wave intensities. WIA can elucidate subtleties among different counterpulsatile support means with high sensitivity. Total accelerating wave intensity (TAWI), which was defined as the sum of the time integration of accelerated parts of the positive and negative wave intensities, was used to quantify counterpulsation efficacy. In general, the larger the TAWI gain, the better the counter-pulsatile support efficacy. However, when PABP deflation timings were delayed to after the R-wave, the TAWI was found to be inversely correlated with coronary perfusion. In this delayed deflation timing setting, greater wave cancellation occurred, which led to decreased TAWI but increased coronary perfusion attributed to blood regurgitation reduction.

Entities:  

Mesh:

Year:  2012        PMID: 22227124     DOI: 10.1152/ajpheart.00551.2011

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  3 in total

1.  Major influence of a 'smoke and mirrors' effect caused by wave reflection on early diastolic coronary arterial wave intensity.

Authors:  Jonathan P Mynard; Daniel J Penny; Joseph J Smolich
Journal:  J Physiol       Date:  2018-02-13       Impact factor: 5.182

2.  Quantification of Pulsed Operation of Rotary Left Ventricular Assist Devices with Wave Intensity Analysis.

Authors:  J Christopher Bouwmeester; Jiheum Park; Arnar Geirsson; John Valdovinos; Pramod Bonde
Journal:  ASAIO J       Date:  2019 May/Jun       Impact factor: 2.872

Review 3.  Evidence of clinical efficacy of counterpulsation therapy methods.

Authors:  M Capoccia; C T Bowles; J R Pepper; N R Banner; A R Simon
Journal:  Heart Fail Rev       Date:  2015-05       Impact factor: 4.214