Literature DB >> 22226267

The ASPIRE study: design and methods of an in-clinic crossover trial on the efficacy of automatic insulin pump suspension in exercise-induced hypoglycemia.

Ronald L Brazg1, Timothy S Bailey, Satish Garg, Bruce A Buckingham, Robert H Slover, David C Klonoff, Xuan Nguyen, John Shin, John B Welsh, Scott W Lee.   

Abstract

BACKGROUND: The Paradigm®Veo™ System includes a low glucose suspend (LGS) feature which suspends insulin delivery when a prespecified glucose threshold setting is reached by the associated continuous glucose monitoring (CGM) sensor. The ASPIRE (Automation to Simulate Pancreatic Insulin REsponse) study is a multicenter, in-clinic, randomized, crossover study to examine the efficacy of LGS in exercise-induced hypoglycemia.
METHODS: Insulin-pump users underwent two separate exercise sessions, one with the LGS feature set to suspend insulin (LGS-on) when the CGM-detected glucose concentration was ≤ 70 mg/dl and one with the LGS feature off. Exercise sessions were conducted after an overnight fast and with initial plasma glucose level as measured by the YSI 2300 STAT Plus glucose analyzer (YSI) of 100-140 mg/dl. Subjects exercised until their YSI value fell to ≤ 85 mg/dl; subsequent YSI values <70 mg/dl were recorded for up to 4 h to measure the duration and nadir of hypoglycemia. The protocol required that subjects with YSI values <50 or >300 mg/dl were rescued with carbohydrates or insulin, respectively, based on the provider's recommendation. The primary end point was comparison of duration and severity of hypoglycemia between LGS-on and LGS-off sessions. Secondary end points included areas under the glucose concentration curve, CGM sensor accuracy, and last YSI glucose. Device- and procedure-related adverse events and serious adverse events were recorded.
RESULTS: Fifty adults and teenagers (17-58 years) with type 1 diabetes were randomized. Study completion is expected in November 2011.
© 2011 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22226267      PMCID: PMC3262716          DOI: 10.1177/193229681100500621

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  5 in total

1.  Semi-closed-loop insulin delivery systems: early experience with low-glucose insulin suspend pumps.

Authors:  John C Pickup
Journal:  Diabetes Technol Ther       Date:  2011-06-13       Impact factor: 6.118

Review 2.  Management of exercise-induced glycemic imbalances in type 1 diabetes.

Authors:  Maria P Francescato; Sergio Carrato
Journal:  Curr Diabetes Rev       Date:  2011-07

3.  Usage and effectiveness of the low glucose suspend feature of the Medtronic Paradigm Veo insulin pump.

Authors:  Pratik Agrawal; John B Welsh; Brian Kannard; Sina Askari; Qingqing Yang; Francine R Kaufman
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

4.  Preventing exercise-induced hypoglycemia in type 1 diabetes using real-time continuous glucose monitoring and a new carbohydrate intake algorithm: an observational field study.

Authors:  Michael C Riddell; Jill Milliken
Journal:  Diabetes Technol Ther       Date:  2011-05-20       Impact factor: 6.118

5.  Increasing the low-glucose alarm of a continuous glucose monitoring system prevents exercise-induced hypoglycemia without triggering any false alarms.

Authors:  Katherine E Iscoe; Raymond J Davey; Paul A Fournier
Journal:  Diabetes Care       Date:  2011-06       Impact factor: 19.112

  5 in total
  6 in total

1.  Factors associated with glycemic control in adult type 1 diabetes patients treated with insulin pump therapy.

Authors:  Bartłomiej Matejko; Jan Skupien; Sandra Mrozińska; Małgorzata Grzanka; Katarzyna Cyganek; Beata Kiec-Wilk; Maciej T Malecki; Tomasz Klupa
Journal:  Endocrine       Date:  2014-05-06       Impact factor: 3.633

2.  Predictors of Hypoglycemia in the ASPIRE In-Home Study and Effects of Automatic Suspension of Insulin Delivery.

Authors:  Ram Weiss; Satish K Garg; Richard M Bergenstal; David C Klonoff; Bruce W Bode; Timothy S Bailey; James Thrasher; Frank Schwartz; John B Welsh; Francine R Kaufman
Journal:  J Diabetes Sci Technol       Date:  2015-05-18

3.  ASPIRE In-Home: rationale, design, and methods of a study to evaluate the safety and efficacy of automatic insulin suspension for nocturnal hypoglycemia.

Authors:  David C Klonoff; Richard M Bergenstal; Satish K Garg; Bruce W Bode; Melissa Meredith; Robert H Slover; Andrew Ahmann; John B Welsh; Scott W Lee
Journal:  J Diabetes Sci Technol       Date:  2013-07-01

Review 4.  Insulin delivery methods: Past, present and future.

Authors:  Rima B Shah; Manhar Patel; David M Maahs; Viral N Shah
Journal:  Int J Pharm Investig       Date:  2016 Jan-Mar

5.  Glycemic Control and Hypoglycemia in Patients Treated with Insulin Pump Therapy: An Observational Study.

Authors:  Guillermo Guzmán; Veline Martínez; Julián David Yara; Miguel Angel Mina; Juan Sebastian Solarte; Angela María Victoria; Karen Fériz
Journal:  J Diabetes Res       Date:  2020-08-05       Impact factor: 4.011

Review 6.  Nanotechnology in Immunotherapy for Type 1 Diabetes: Promising Innovations and Future Advances.

Authors:  Saumya Nigam; Jack Owen Bishop; Hanaan Hayat; Tahnia Quadri; Hasaan Hayat; Ping Wang
Journal:  Pharmaceutics       Date:  2022-03-15       Impact factor: 6.321

  6 in total