Literature DB >> 22225297

On the dosimetric effect and reduction of inverse consistency and transitivity errors in deformable image registration for dose accumulation.

Edward T Bender1, Nicholas Hardcastle, Wolfgang A Tomé.   

Abstract

PURPOSE: Deformable image registration (DIR) is necessary for accurate dose accumulation between multiple radiotherapy image sets. DIR algorithms can suffer from inverse and transitivity inconsistencies. When using deformation vector fields (DVFs) that exhibit inverse-inconsistency and are nontransitive, dose accumulation on a given image set via different image pathways will lead to different accumulated doses. The purpose of this study was to investigate the dosimetric effect of and propose a postprocessing solution to reduce inverse consistency and transitivity errors.
METHODS: Four MVCT images and four phases of a lung 4DCT, each with an associated calculated dose, were selected for analysis. DVFs between all four images in each data set were created using the Fast Symmetric Demons algorithm. Dose was accumulated on the fourth image in each set using DIR via two different image pathways. The two accumulated doses on the fourth image were compared. The inverse consistency and transitivity errors in the DVFs were then reduced. The dose accumulation was repeated using the processed DVFs, the results of which were compared with the accumulated dose from the original DVFs. To evaluate the influence of the postprocessing technique on DVF accuracy, the original and processed DVF accuracy was evaluated on the lung 4DCT data on which anatomical landmarks had been identified by an expert.
RESULTS: Dose accumulation to the same image via different image pathways resulted in two different accumulated dose results. After the inverse consistency errors were reduced, the difference between the accumulated doses diminished. The difference was further reduced after reducing the transitivity errors. The postprocessing technique had minimal effect on the accuracy of the DVF for the lung 4DCT images.
CONCLUSIONS: This study shows that inverse consistency and transitivity errors in DIR have a significant dosimetric effect in dose accumulation; Depending on the image pathway taken to accumulate the dose, different results may be obtained. A postprocessing technique that reduces inverse consistency and transitivity error is presented, which allows for consistent dose accumulation regardless of the image pathway followed.

Mesh:

Year:  2012        PMID: 22225297     DOI: 10.1118/1.3666948

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  The distance discordance metric-a novel approach to quantifying spatial uncertainties in intra- and inter-patient deformable image registration.

Authors:  Ziad H Saleh; Aditya P Apte; Gregory C Sharp; Nadezhda P Shusharina; Ya Wang; Harini Veeraraghavan; Maria Thor; Ludvig P Muren; Shyam S Rao; Nancy Y Lee; Joseph O Deasy
Journal:  Phys Med Biol       Date:  2014-01-20       Impact factor: 3.609

2.  On voxel-by-voxel accumulated dose for prostate radiation therapy using deformable image registration.

Authors:  Jialu Yu; Nicholas Hardcastle; Kyoungkeun Jeong; Edward T Bender; Mark A Ritter; Wolfgang A Tomé
Journal:  Technol Cancer Res Treat       Date:  2014-11-11

3.  A multiple-image-based method to evaluate the performance of deformable image registration in the pelvis.

Authors:  Ziad Saleh; Maria Thor; Aditya P Apte; Gregory Sharp; Xiaoli Tang; Harini Veeraraghavan; Ludvig Muren; Joseph Deasy
Journal:  Phys Med Biol       Date:  2016-07-29       Impact factor: 3.609

4.  Effect of deformable registration uncertainty on lung SBRT dose accumulation.

Authors:  Navid Samavati; Michael Velec; Kristy K Brock
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

5.  A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive.

Authors:  Richard Castillo; Edward Castillo; David Fuentes; Moiz Ahmad; Abbie M Wood; Michelle S Ludwig; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2013-04-10       Impact factor: 3.609

6.  MIRSIG position paper: the use of image registration and fusion algorithms in radiotherapy.

Authors:  Nicholas Lowther; Rob Louwe; Johnson Yuen; Nicholas Hardcastle; Adam Yeo; Michael Jameson
Journal:  Phys Eng Sci Med       Date:  2022-05-06

7.  Inverse consistent non-rigid image registration based on robust point set matching.

Authors:  Xuan Yang; Jihong Pei; Jingli Shi
Journal:  Biomed Eng Online       Date:  2014-12-11       Impact factor: 2.819

8.  Validation of a dose warping algorithm using clinically realistic scenarios.

Authors:  Y G Roussakis; H Dehghani; S Green; G J Webster
Journal:  Br J Radiol       Date:  2015-03-20       Impact factor: 3.039

9.  The effects of computed tomography image characteristics and knot spacing on the spatial accuracy of B-spline deformable image registration in the head and neck geometry.

Authors:  Charlotte L Brouwer; Roel G J Kierkels; Aart A van 't Veld; Nanna M Sijtsema; Harm Meertens
Journal:  Radiat Oncol       Date:  2014-07-29       Impact factor: 3.481

10.  Registering prostate external beam radiotherapy with a boost from high-dose-rate brachytherapy: a comparative evaluation of deformable registration algorithms.

Authors:  Calyn R Moulton; Michael J House; Victoria Lye; Colin I Tang; Michele Krawiec; David J Joseph; James W Denham; Martin A Ebert
Journal:  Radiat Oncol       Date:  2015-12-14       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.