Literature DB >> 22223943

Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques.

S Timothy Chelliah1, Shyamkumar N Keshava, Vinu Moses, Narayanam Rs Surendrababu, Uday George Zachariah, Ce Eapen.   

Abstract

AIMS: To evaluate the accuracy of measurement of hepatic venous pressure gradient by catheter wedge as compared to balloon wedge (the gold standard).
MATERIALS AND METHODS: Forty-five patients having a clinical diagnosis of intrahepatic portal hypertension were subjected to the two different types of pressure measurements (catheter wedge and balloon wedge) during transjugular liver biopsy under fluoroscopic guidance. STATISTICAL ANALYSIS: Spearman's rank correlation coefficient, Bland-Altman plot for agreement, and single measure intraclass correlation were used for analysis of data.
RESULTS: There was a close correlation between the results obtained by both the techniques, with highly significant concordance (P < 0.0001). Hepatic venous pressure gradients as measured by the catheter wedge technique were either equal to or less than those obtained by the balloon wedge technique.
CONCLUSIONS: The difference in hepatic venous pressure gradients measured by the two techniques is insignificant.

Entities:  

Keywords:  Balloon wedge hepatic venous pressure; catheter wedge hepatic venous pressure; free hepatic venous pressure; hepatic venous pressure gradient

Year:  2011        PMID: 22223943      PMCID: PMC3249946          DOI: 10.4103/0971-3026.90693

Source DB:  PubMed          Journal:  Indian J Radiol Imaging        ISSN: 0970-2016


Introduction

Hepatic venous wedge pressure (HVWP) is a dynamic variable reflecting the hepatic sinusoidal pressure and therefore, indirectly, the portal pressure.[1] It is used to calculate the hepatic venous pressure gradient (HVPG),[2] the normal value being between 1 and 5 mmHg.[34] The current gold standard technique for measuring HVWP is the balloon wedge method.[34] The clinical importance of measuring HVPG in portal hypertension is well documented in the literature.[34] Because of the technical difficulties associated with the balloon wedge technique, the potential for hepatic venous intimal injury, and the added cost of a balloon catheter, an alternative method with equivalent accuracy would be useful. We conducted the current study with the aim of determining whether a significant difference existed in the HVPG if measured using the conventional catheter wedge method.

Materials and Methods

From May 2007 to June 2008, 45 patients having a clinical diagnosis of intrahepatic portal hypertension due to etiologies that included viral (hepatitis B and C), autoimmune, metabolic (Wilson disease), cryptogenic cirrhosis, and noncirrhotic intrahepatic portal hypertension referred to our department for hepatic vein pressure measurements and transjugular liver biopsy (TJLB), were included in this study. Of the 45 patients with a mean age 41.6 ± 12.8 years, 30 were male. Cases of Budd-Chiari syndrome were excluded.

Definitions

HVWP is a dynamic variable indirectly reflecting the sinusoidal pressure.[5] HVPG is the difference in the HVWP and the free hepatic venous pressure (FHVP).[5]

Measurement of hepatic vein pressures

The procedure was done under local anesthesia. The right internal jugular vein was accessed under ultrasonography guidance. A 9F sheath (Cook Medical, Bloomington, USA) was placed instead of a 6F sheath (Cook Medical) if the patient had to undergo a TJLB. The right hepatic vein was selectively cannulated under fluoroscopy using a 5F multipurpose catheter and a 0.035′ guidewire (Cordis, Miami, FL, USA). An angiogram was performed to confirm the location of the catheter. Right atrial pressure and FHVP were then recorded. Subsequently, the catheter was wedged against the hepatic parenchyma and three pressures were recorded at different sites . We ensured that there was no contrast in the catheter during pressure measurement. All pressures were measured using an Agilent; monitor with a quartz pressure transducer. The catheter was exchanged for a balloon catheter (6F/7F Swan Ganz, Edwards Lifesciences, Irvine, USA) over a 0.030’/0.035’ guidewire (Emerald, Cordis, Miami, FL, USA). The balloon was inflated using 50% iodinated contrast (iohexol, 300 mgI/mL, Omnipaque, GE Healthcare, Shanghai, China) in normal saline until the balloon flattened against the walls of the hepatic vein and the pressure through the lumen of the balloon catheter was recorded [Figure 1].
Figure 1 (A, B)

Contrast study shows hepatic venogram (A) and balloon wedging (B)

Contrast study shows hepatic venogram (A) and balloon wedging (B) Hepatic venous pressure gradient measured using catheter wedge method and balloon wedge method with the line of equality TJLB was done whenever requested. The sheath was removed and external compression was applied at the puncture site for hemostasis.

Statistical analysis

For statistical analysis of the results we used three different methods. In the first method, we calculated the Spearman's rank correlation coefficient, that is, Spearman's rho (ρ).[6] The second method was the Bland-Altman plot for agreement,[78] which can be used to compare a new measurement technique or method with a gold standard. In the final method of comparison, the correlation coefficient was calculated by single-measure intraclass correlation.[9]

Results

The measured values of both catheter wedge and balloon wedge HVPGs are plotted in Figure 2, along with the line of equality. Statistical analysis was done using the 3 different methods as explained:
Figure 2

Hepatic venous pressure gradient measured using catheter wedge method and balloon wedge method with the line of equality

Bland–Altman plot for agreement of catheter wedge and balloon wedge techniques Spearman's correlation coefficient (ρ) was found to be 0.876, with P < 0.01, showing that there is a significant correlation. The Bland–Altman plot for agreement between catheter wedge and balloon wedge pressure gradients [Figure 3] showed good correlation.
Figure 3

Bland–Altman plot for agreement of catheter wedge and balloon wedge techniques

The intraclass correlation coefficient was 0.8895, with P < 0.001, showing that the correlation is significant. Subgroup analysis (1–12, 13–20, and >20 mmHg) was not possible because there weren’t enough cases in the 2nd and 3rd subgroups to allow any significant statistical correlation. All the patients tolerated the procedure well and there were no postprocedural complications.

Discussion

HVWP measurement plays an integral role in the evaluation of patients with portal hypertension. A few important applications include the assessment of portal pressure in cirrhosis to predict risk of formation of varices (HVPG > 12 mmHg) or the risk of rebleeding from varices (HVPG > 20 mmHg), to assess the response to pharmacologic agents during treatment of portal hypertension (>20% fall in HVPG from baseline), and to help differentiate between presinusoidal (as in the case of noncirrhotic portal hypertension) and sinusoidal causes of portal hypertension.[21011] Hence HVPG monitoring provides important information for patients undergoing treatment for the prevention of variceal bleeding or rebleeding, allowing identification of patients who will be effectively protected against the risk of bleeding and those who, by not achieving an HVPG reduction by 20% of baseline or to ≤2 mmHg, remain at a very high risk of bleeding.[12] There is only one similar study in the literature; that study, done by Barth and Udoffin 1980, compared the HVPGs in a smaller number (11) of patients with alcoholic cirrhosis as measured by balloon wedge and catheter wedge techniques. Variations in results between the 2 methods ranged up to 3 mmHg, with all patients having elevated hepatic wedge pressures of 15-25 mgHg. They found that the difference was insignificant.[1] Our study includes patients of varied etiology and a wide range of HVPGs of 1–30 mmHg.

Comparison of techniques

The catheter wedge technique is relatively easy to perform but requires multiple measurements of HVWP. Sometimes it needs injection of contrast media to confirm the wedge position. There are certain risks associated with this technique, such as perforation of the vessel by the guide wire or catheter or hepatic parenchymal damage by forceful contrast injection. On the other hand, the balloon wedge technique results are more representative of average parenchymal pressure than the standard wedged catheter measurements. It requires a balloon and an exchange wire, is more time consuming, and exposes patients to slightly higher levels of radiation. Enlargement of the puncture site with severe bleeding may occur with dislodgement of the incompletely deflated balloon. So prior to withdrawal of the catheter through the puncture site, complete balloon deflation is necessary.[1] Potential intimal injury is a rare but important complication with the balloon wedge technique. The total cost of HVPG measurement at our center using the catheter wedge technique is INR 8000. The use of the balloon catheter would result in an additional cost of INR 2000.
  9 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

Review 2.  The hepatic venous pressure gradient: anything worth doing should be done right.

Authors:  Roberto J Groszmann; Suchat Wongcharatrawee
Journal:  Hepatology       Date:  2004-02       Impact factor: 17.425

Review 3.  Measurement of portal pressure: when, how, and why to do it.

Authors:  Roberto Groszmann; Julio D Vorobioff; Hong Gao
Journal:  Clin Liver Dis       Date:  2006-08       Impact factor: 6.126

4.  Wedged hepatic vein pressure (WHVP): ready for prime time.

Authors:  Thomas D Boyer
Journal:  Hepatology       Date:  2006-03       Impact factor: 17.425

5.  The proof and measurement of association between two things. By C. Spearman, 1904.

Authors:  C Spearman
Journal:  Am J Psychol       Date:  1987 Fall-Winter

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Transfemoral balloon catheterization for hepatic wedge pressure measurements.

Authors:  K H Barth; E J Udoff
Journal:  Radiology       Date:  1980-06       Impact factor: 11.105

Review 8.  Hepatic vein pressure gradient reduction and prevention of variceal bleeding in cirrhosis: a systematic review.

Authors:  Gennaro D'Amico; Juan Carlos Garcia-Pagan; Angelo Luca; Jaime Bosch
Journal:  Gastroenterology       Date:  2006-11       Impact factor: 22.682

9.  Idiopathic non-cirrhotic intrahepatic portal hypertension: common cause of cryptogenic intrahepatic portal hypertension in a Southern Indian tertiary hospital.

Authors:  Kadiyala Madhu; Balekuduru Avinash; Banumathi Ramakrishna; C E Eapen; N K Shyamkumar; Uday Zachariah; George Chandy; George Kurian
Journal:  Indian J Gastroenterol       Date:  2009-11-12
  9 in total
  4 in total

1.  Comprehensive Predictors of Portal Pressure from Functional Liver Reserve in Patients Who Underwent Hepatectomy.

Authors:  Atsushi Nanashima; Takafumi Abo; Junichi Arai; Tomoshi Tsuchiya; Takuro Miyazaki; Katsunori Takagi; Xiaohui Chen; Takeshi Nagayasu
Journal:  Indian J Surg       Date:  2014-04-10       Impact factor: 0.656

2.  Use of serum vitamin B12 level as a marker to differentiate idiopathic noncirrhotic intrahepatic portal hypertension from cryptogenic cirrhosis.

Authors:  Ashish Goel; Banumathi Ramakrishna; Jayaprakash Muliyil; Kadiyala Madhu; K G Sajith; Uday Zachariah; Jeyamani Ramachandran; Shyamkumar N Keshava; R Selvakumar; George M Chandy; Elwyn Elias; C E Eapen
Journal:  Dig Dis Sci       Date:  2012-08-24       Impact factor: 3.199

Review 3.  What makes non-cirrhotic portal hypertension a common disease in India? Analysis for environmental factors.

Authors:  Ashish Goel; Banumathi Ramakrishna; Uday Zachariah; K G Sajith; Deepak K Burad; Thomas A Kodiatte; Shyamkumar N Keshava; K A Balasubramanian; Elwyn Elias; C E Eapen
Journal:  Indian J Med Res       Date:  2019-04       Impact factor: 2.375

Review 4.  Indian College of Radiology and Imaging Evidence-Based Guidelines for Interventions in Portal Hypertension and Its Complications.

Authors:  Amar Mukund; Shaleen Rana; Chander Mohan; Naveen Kalra; Sanjay Saran Baijal
Journal:  Indian J Radiol Imaging       Date:  2022-01-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.