Literature DB >> 22223157

Influence of image metrics when assessing image quality from a test object in cardiac X-ray systems: Part II.

Roberto Sanchez1, Eliseo Vano, Carlos Ubeda, Jose M Fernandez, Stephen Balter, Bart Hoornaert.   

Abstract

The images generated in modern IC laboratories are created with high-quality standard (1,024×1,024 pixels and 10-12 bits/pixel) enabling cardiologists to perform interventions in the best conditions. But these images are in most of the cases archived in a basic quality standard (512×512 pixels and 8 bits/pixel). The purpose of this work is to complete the research developed in a previous paper and analyze the influence of the matrix size and the bit depth reduction on the image quality acquired on a polymethylmethacrylate (PMMA) phantom with a test object. The variation in contrast-to-noise ratio (CNR) and high contrast spatial resolution (HCSR) were investigated when the matrix size and the bit depth were independently modified for different phantom thicknesses. These two image quality parameters did not suffer noticeable alterations under bits depth reduction from 10 to 8 bits. Such a result seems to imply that bits depth reduction could be used to reduce file sizes with a suitable algorithm and without losing perceptible image quality information. But when the matrix size was reduced from 1,024×1,024 to 512×512 pixels, a reduction from 17% to 25% in HCSR was noticed when changing phantom thickness, and an increase of 27% in CNR was observed. These findings should be taken into account and it would be wise to conduct further investigations in the field of clinical images.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22223157      PMCID: PMC3389093          DOI: 10.1007/s10278-011-9448-0

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  12 in total

1.  American College of Cardiology/European Society of Cardiology International Study of Angiographic Data Compression Phase I: The effect of lossy data compression on recognition of diagnostic features in digital coronary angiography.

Authors:  R A Kerensky; J T Cusma; P Kubilis; R Simon; T M Bashore; J W Hirshfeld; D R Holmes; C J Pepine; S E Nissen
Journal:  J Am Coll Cardiol       Date:  2000-04       Impact factor: 24.094

2.  Introduction and background: the International Angiographic Compression study.

Authors:  S E Nissen; J W Hirshfeld; R Simon
Journal:  J Am Coll Cardiol       Date:  2000-04       Impact factor: 24.094

3.  American College of Cardiology/European Society of Cardiology International Study of Angiographic Data Compression Phase III: measurement of image quality differences at varying levels of data compression.

Authors:  R Brennecke; U Bürgel; R Simon; G Rippin; H P Fritsch; T Becker; S E Nissen
Journal:  J Am Coll Cardiol       Date:  2000-04       Impact factor: 24.094

4.  Assessment of noise in a digital image using the join-count statistic and the Moran test.

Authors:  K S Chuang; H K Huang
Journal:  Phys Med Biol       Date:  1992-02       Impact factor: 3.609

5.  Signal detectability in digital radiography: spatial domain figures of merit.

Authors:  Robert M Gagne; Jonathan S Boswell; Kyle J Myers
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

6.  Impact of various compression rates on interpretation of digital coronary angiograms.

Authors:  S Silber; R Dörr; G Zindler; H Mühling; T Diebel
Journal:  Int J Cardiol       Date:  1997-07-25       Impact factor: 4.164

7.  Effective doses to patients from paediatric cardiac catheterization.

Authors:  J Rassow; A A Schmaltz; F Hentrich; C Streffer
Journal:  Br J Radiol       Date:  2000-02       Impact factor: 3.039

8.  Application of European protocol in the evaluation of contrast-to-noise ratio and mean glandular dose for two digital mammography systems.

Authors:  W E Muhogora; A Devetti; R Padovani; P Msaki; F Bonutti
Journal:  Radiat Prot Dosimetry       Date:  2008-02-18       Impact factor: 0.972

Review 9.  European guidelines for quality assurance in breast cancer screening and diagnosis. Fourth edition--summary document.

Authors:  N Perry; M Broeders; C de Wolf; S Törnberg; R Holland; L von Karsa
Journal:  Ann Oncol       Date:  2007-11-17       Impact factor: 32.976

10.  DICOM media interchange standards for cardiology: initial interoperability demonstration.

Authors:  J L Elion
Journal:  Proc Annu Symp Comput Appl Med Care       Date:  1995
View more
  1 in total

1.  Tracking unfolding and refolding reactions of single proteins using atomic force microscopy methods.

Authors:  Paul J Bujalowski; Andres F Oberhauser
Journal:  Methods       Date:  2013-03-20       Impact factor: 3.608

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.