Current status on stentless aortic bioprosthesis: a clinical and experimental perspective.

Jonas Amstrup Funder1.   

Abstract

Introduction of stentless valves into clinical practice has not replaced stented valve prosthesis as expected a decade ago. With respect to clinical parameters such as transvalvular pressure differences, left ventricular mass regression as well as a possible survival benefit, there are many contradictory studies published. The overall dilemma is the absence of large randomized studies. This review, therefore, focuses on two issues: Experimental research in order to disclose design advantages or drawbacks and clinical trials expressing the real benefit or risk for the patient. In general, both clinical and experimental studies show that stentless valves have several biomechanical and haemodynamic benefits when compared with stented valves though new generation pericardial valves have excellent blood flow profiles. However, stentless and stented valves seem to perform equally well when it comes to various clinical parameters. In most cases, a stented valve is therefore preferable because of the simpler implantation technique. In order to gain a more widespread clinical use, the design of the stentless valve needs to be improved in order to simplify the implantation.

Entities:  

Mesh:

Year:  2011        PMID: 22219434     DOI: 10.1093/ejcts/ezr141

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  3 in total

1.  Blood flow characteristics in the ascending aorta after aortic valve replacement--a pilot study using 4D-flow MRI.

Authors:  Florian von Knobelsdorff-Brenkenhoff; Ralf F Trauzeddel; Alex J Barker; Henriette Gruettner; Michael Markl; Jeanette Schulz-Menger
Journal:  Int J Cardiol       Date:  2013-11-25       Impact factor: 4.164

Review 2.  Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance.

Authors:  Joao S Soares; Kristen R Feaver; Will Zhang; David Kamensky; Ankush Aggarwal; Michael S Sacks
Journal:  Cardiovasc Eng Technol       Date:  2016-08-09       Impact factor: 2.495

3.  Early and mid-term haemodynamic performance and clinical outcomes of St. Jude Medical Trifecta™ valve.

Authors:  Renata Raimundo; Soraia Moreira; Francisca Saraiva; Rui J Cerqueira; Pedro Teixeira; Elson Salgueiro; André Lourenço; Mário J Amorim; Jorge Almeida; Paulo Pinho; Adelino F Leite-Moreira
Journal:  J Thorac Dis       Date:  2018-02       Impact factor: 2.895

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.