Literature DB >> 22214677

Contrast-enhanced ultrasound improves real-time imaging of ablation region during radiofrequency ablation: preliminary results.

P Wiggermann1, I Zuber-Jerger, Y Zausig, M Loss, M N Scherer, A G Schreyer, C Stroszczynski, E M Jung.   

Abstract

PURPOSE: To assess the added value of depicting tumour microvascularisation, using dynamic contrast enhanced (CEUS), during radiofrequency ablation, as a means of achieving a complete ablation (CA) of malignant liver lesions.
MATERIAL AND METHODS: 18 consecutive patients (2 female, 16 male, age range 52-79 years, mean 64.1 ± 9.9 years) with 22 histologically confirmed hepatic malignancies (HCC: n = 10, liver metastases: n = 12) underwent RFA. Before RFA treatment, conventional US, CEUS and contrast enhanced CT (ceCT) of the liver were performed. During the CT-guided RFA procedure, CEUS was performed to asses the ablation defect. In case of partial ablation a subsequent ablation was performed with a corrected electrode position and evaluated again using CEUS. This procedure was repeated until a CA was achieved. The number of ablations per patient was recorded. Secondary efficacy parameters assessed were lesion detectability in the different imaging modalities and contrast phases.
RESULTS: Overall intraprocedural CEUS led to a change in therapeutic management in 59% of cases, resulting in 17 additional ablation cycles. Lesion detectability during CT Fluoroscopy was the sole statistical significant predictor of incomplete ablations (p = 0.008). The mean number of ablations for detectable lesions was 1.27 vs. 2.27 ablations for not detectable lesions (p = 0.002). The combined CT and CEUS RFA procedure led to a CA for all treated lesions in follow up 3 month post intervention.
CONCLUSION: CEUS does allow a reliable and immediate assessment of therapeutic efficacy of percutaneous RFA procedures of malignant liver lesions, through the continuous dynamic evaluation of tumour microcirculation.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22214677     DOI: 10.3233/CH-2011-1456

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  9 in total

1.  [Interventional sonography of the liver and kidneys].

Authors:  D-A Clevert; E M Jung
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

2.  Diagnostic accuracy of contrast-enhanced ultrasound in assessing the therapeutic response to radio frequency ablation for liver tumors: systematic review and meta-analysis.

Authors:  Min Xuan; Fengsheng Zhou; Yan Ding; Qiaoying Zhu; Ji Dong; Hao Zhou; Jun Cheng; Xiao Jiang; Pengxi Wu
Journal:  Surg Endosc       Date:  2017-12-21       Impact factor: 4.584

3.  MR-guided radiofrequency ablation using a wide-bore 1.5-T MR system: clinical results of 213 treated liver lesions.

Authors:  Hansjörg Rempp; Lorenz Waibel; Rüdiger Hoffmann; Claus D Claussen; Philippe L Pereira; Stephan Clasen
Journal:  Eur Radiol       Date:  2012-04-18       Impact factor: 5.315

Review 4.  Contrast Agents for Hepatocellular Carcinoma Imaging: Value and Progression.

Authors:  Ying Zhang; Kazushi Numata; Yuewu Du; Shin Maeda
Journal:  Front Oncol       Date:  2022-06-02       Impact factor: 5.738

5.  Hepatocellular carcinoma after ablation: the imaging follow-up scheme.

Authors:  Lin-Na Liu; Hui-Xiong Xu; Yi-Feng Zhang; Jun-Mei Xu
Journal:  World J Gastroenterol       Date:  2013-02-14       Impact factor: 5.742

6.  Radiofrequency ablation for postsurgical thyroid removal of differentiated thyroid carcinoma.

Authors:  Dong Xu; Lipin Wang; Bin Long; Xuemei Ye; Minghua Ge; Kejing Wang; Liang Guo; Linfa Li
Journal:  Am J Transl Res       Date:  2016-04-15       Impact factor: 4.060

7.  Evaluation of Contrast-Enhanced Intraoperative Ultrasound in the Detection and Management of Liver Lesions in Patients with Hepatocellular Carcinoma.

Authors:  Cristina Pace; Vittorio Nardone; Silvia Roma; Fabrizio Chegai; Luca Toti; Tommaso Maria Manzia; Giuseppe Tisone; Antonio Orlacchio
Journal:  J Oncol       Date:  2019-08-05       Impact factor: 4.375

8.  Contrast enhancement for ultrasound-guided interventions: when to use it and what to expect?

Authors:  Zeno Sparchez; Tudor Mocan; Rares Craciun; Mihaela Sparchez; Christian Nolsøe
Journal:  Ultrasonography       Date:  2021-12-09

9.  Block-matching-based registration to evaluate ultrasound visibility of percutaneous needles in liver-mimicking phantoms.

Authors:  Juan A Sánchez-Margallo; Lisette Tas; Adriaan Moelker; John J van den Dobbelsteen; Francisco M Sánchez-Margallo; Thomas Langø; Theo van Walsum; Nick J van de Berg
Journal:  Med Phys       Date:  2021-10-31       Impact factor: 4.506

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.