Literature DB >> 24177722

[Interventional sonography of the liver and kidneys].

D-A Clevert1, E M Jung.   

Abstract

CLINICAL/METHODICAL ISSUE: Optimization of ultrasound guided interventional procedures of the liver and kidneys using new imaging methods. STANDARD RADIOLOGICAL
METHODS: Punctures, biopsies, drainage, intraoperative ultrasound, fusion, embolization in correlation with ultrasound and other imaging methods. METHODICAL INNOVATIONS: Real-time-sonography, contrast-enhanced ultrasound (CEUS) and fusion for planning, monitoring and postinterventional control. PERFORMANCE: The use of CEUS enables better detection, characterization and execution of interventional procedures. Fusion facilitates detection. ACHIEVEMENTS: The CEUS procedure is superior for detection and characterization of smaller lesions in comparison to the B scan. Fusion enables the performance of difficult interventional procedures. PRACTICAL RECOMMENDATIONS: The B scan is the standard imaging method but CEUS and fusion could be helpful for smaller lesions.

Mesh:

Year:  2013        PMID: 24177722     DOI: 10.1007/s00117-012-2459-0

Source DB:  PubMed          Journal:  Radiologe        ISSN: 0033-832X            Impact factor:   0.635


  48 in total

1.  Diagnostic accuracy of CEUS in the differential diagnosis of small (≤ 20  mm) and subcentimetric (≤ 10  mm) focal liver lesions in comparison with histology. Results of the DEGUM multicenter trial.

Authors:  D Strobel; T Bernatik; W Blank; A Schuler; C Greis; C F Dietrich; K Seitz
Journal:  Ultraschall Med       Date:  2011-12-09       Impact factor: 6.548

Review 2.  From the RSNA refresher courses: a practical approach to the cystic renal mass.

Authors:  David S Hartman; Peter L Choyke; Matthew S Hartman
Journal:  Radiographics       Date:  2004-10       Impact factor: 5.333

3.  Dynamic evaluation and quantification of microvascularization during degradable starch microspheres transarterial Chemoembolisation (DSM-TACE) of HCC lesions using contrast enhanced ultrasound (CEUS): a feasibility study.

Authors:  P Wiggermann; W A Wohlgemuth; M Heibl; A Vasilj; M Loss; A G Schreyer; C Stroszczynski; E M Jung
Journal:  Clin Hemorheol Microcirc       Date:  2013       Impact factor: 2.375

4.  Radiofrequency ablation combined with chemoembolization for intermediate-sized (3-5 cm) hepatocellular carcinomas under dual guidance of biplane fluoroscopy and ultrasonography.

Authors:  Ji Hye Min; Min Woo Lee; Dong Ik Cha; Yong Hwan Jeon; Sung Wook Shin; Sung Ki Cho; Hyunchul Rhim; Hyo K Lim
Journal:  Korean J Radiol       Date:  2013-02-22       Impact factor: 3.500

5.  Defining the complications of cryoablation and radio frequency ablation of small renal tumors: a multi-institutional review.

Authors:  D Brooke Johnson; Stephen B Solomon; Li-Ming Su; Edward D Matsumoto; Louis R Kavoussi; Stephen Y Nakada; Timothy D Moon; W Bruce Shingleton; Jeffrey A Cadeddu
Journal:  J Urol       Date:  2004-09       Impact factor: 7.450

6.  Clinical application of transcatheter arterial chemoembolization combined with synchronous C-arm cone-beam CT guided radiofrequency ablation in treatment of large hepatocellular carcinoma.

Authors:  Zhi-Jun Wang; Mao-Qiang Wang; Feng Duan; Peng Song; Feng-Yong Liu; Yan Wang; Jie-Yu Yan; Kai Li; Kai Yuan
Journal:  Asian Pac J Cancer Prev       Date:  2013

7.  Role of contrast-enhanced ultrasonography in percutaneous radiofrequency ablation of liver metastases and efficacy evaluation.

Authors:  Jie Wu; Wei Yang; Shanshan Yin; Jinyu Wu; Wei Wu; Kun Yan; Minhua Chen
Journal:  Chin J Cancer Res       Date:  2013-04       Impact factor: 5.087

8.  The current radiological approach to renal cysts.

Authors:  M A Bosniak
Journal:  Radiology       Date:  1986-01       Impact factor: 11.105

9.  Multislice computed tomography versus contrast-enhanced ultrasound in evaluation of complex cystic renal masses using the Bosniak classification system.

Authors:  D-A Clevert; N Minaifar; S Weckbach; E M Jung; K Stock; M Reiser; M Staehler
Journal:  Clin Hemorheol Microcirc       Date:  2008       Impact factor: 2.375

10.  Timing of complications in percutaneous renal biopsy.

Authors:  William L Whittier; Stephen M Korbet
Journal:  J Am Soc Nephrol       Date:  2004-01       Impact factor: 10.121

View more
  3 in total

Review 1.  [Possibilities of sonographic image fusion: Current developments].

Authors:  E M Jung; D-A Clevert
Journal:  Radiologe       Date:  2015-11       Impact factor: 0.635

Review 2.  [Biopsies of kidney lesions: when and how?]

Authors:  A H Schuster; N Reimann
Journal:  Radiologe       Date:  2018-10       Impact factor: 0.635

Review 3.  [Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].

Authors:  E M Jung; D A Clevert
Journal:  Radiologe       Date:  2018-06       Impact factor: 0.635

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.