Literature DB >> 22213371

SWIFT-CEST: a new MRI method to overcome T₂ shortening caused by PARACEST contrast agents.

Todd C Soesbe1, Osamu Togao, Masaya Takahashi, A Dean Sherry.   

Abstract

The exchange of water molecules between the inner sphere of a paramagnetic chemical exchange saturation transfer (PARACEST) contrast agent and bulk water can shorten the bulk water T(2) through the T(2) -exchange (T(2ex) ) mechanism. The line-broadening T(2ex) effect is proportional to the agent concentration, the chemical shift of the exchanging water molecule, and is highly dependent on the water molecule exchange rate. A significant T(2ex) contribution to the bulk water linewidth can make the regions of agent uptake appear dark when imaging with conventional sequences like gradient-echo and fast spin-echo. The minimum echo times for these sequences (1-10 ms) are not fast enough to capture signal from the regions of shortened T(2) . This makes "Off" (saturation at -Δω) minus "On" (saturation at +Δω) imaging of PARACEST agents difficult, because the regions of uptake are dark in both images. It is shown here that the loss of bulk water signal due to T(2ex) can be reclaimed using the ultrashort echo times (<10 μs) achieved with the sweep imaging with Fourier transform pulse sequence. Modification of the sweep imaging with Fourier transform sequence for PARACEST imaging is first discussed, followed by parameter optimization using in vitro experiments. In vivo PARACEST studies comparing fast spin-echo to sweep imaging with Fourier transform were performed using EuDOTA-(gly) 4- uptake in healthy mouse kidneys. The results show that the negative contrast caused by T(2ex) can be overcome using the ultrashort echo time achieved with sweep imaging with Fourier transform, thereby enabling fast and sensitive in vivo PARACEST imaging.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22213371      PMCID: PMC3422602          DOI: 10.1002/mrm.23302

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  27 in total

Review 1.  Molecular imaging.

Authors:  R Weissleder; U Mahmood
Journal:  Radiology       Date:  2001-05       Impact factor: 11.105

2.  Novel pH-reporter MRI contrast agents.

Authors:  Silvio Aime; Daniela Delli Castelli; Enzo Terreno
Journal:  Angew Chem Int Ed Engl       Date:  2002-11-15       Impact factor: 15.336

3.  Selective sensing of zinc ions with a PARACEST contrast agent.

Authors:  Robert Trokowski; Jimin Ren; Ferenc Krisztián Kálmán; A Dean Sherry
Journal:  Angew Chem Int Ed Engl       Date:  2005-10-28       Impact factor: 15.336

4.  Solvent suppression in high-resolution proton nuclear magnetic resonance based on control of transverse relaxation rate.

Authors:  T M Eads; S D Kennedy; R G Bryant
Journal:  Anal Chem       Date:  1986-07       Impact factor: 6.986

5.  A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

Authors:  S Aime; R Nano; M Grandi
Journal:  Invest Radiol       Date:  1988-09       Impact factor: 6.016

6.  Iopamidol: Exploring the potential use of a well-established x-ray contrast agent for MRI.

Authors:  Silvio Aime; Luisella Calabi; Luca Biondi; Mario De Miranda; Stefano Ghelli; Lino Paleari; Cristina Rebaudengo; Enzo Terreno
Journal:  Magn Reson Med       Date:  2005-04       Impact factor: 4.668

7.  Chemical exchange saturation transfer (CEST): what is in a name and what isn't?

Authors:  Peter C M van Zijl; Nirbhay N Yadav
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

8.  Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo.

Authors:  S D Wolff; R S Balaban
Journal:  Magn Reson Med       Date:  1989-04       Impact factor: 4.668

9.  Polymeric PARACEST agents for enhancing MRI contrast sensitivity.

Authors:  Yunkou Wu; Youfu Zhou; Olivier Ouari; Mark Woods; Piyu Zhao; Todd C Soesbe; Garry E Kiefer; A Dean Sherry
Journal:  J Am Chem Soc       Date:  2008-09-26       Impact factor: 15.419

10.  PARACEST MRI with improved temporal resolution.

Authors:  Guanshu Liu; M Meser Ali; Byunghee Yoo; Mark A Griswold; Jean A Tkach; Mark D Pagel
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

View more
  8 in total

Review 1.  Advantages of paramagnetic chemical exchange saturation transfer (CEST) complexes having slow to intermediate water exchange properties as responsive MRI agents.

Authors:  Todd C Soesbe; Yunkou Wu; A Dean Sherry
Journal:  NMR Biomed       Date:  2012-10-11       Impact factor: 4.044

2.  A nano-sized PARACEST-fluorescence imaging contrast agent facilitates and validates in vivo CEST MRI detection of glioma.

Authors:  Meser M Ali; Mohammed Pi Bhuiyan; Branislava Janic; Nadimpalli Rs Varma; Tom Mikkelsen; James R Ewing; Robert A Knight; Mark D Pagel; Ali S Arbab
Journal:  Nanomedicine (Lond)       Date:  2012-08-14       Impact factor: 5.307

3.  Phenols as Diamagnetic T2 -Exchange Magnetic Resonance Imaging Contrast Agents.

Authors:  Jia Zhang; Yuguo Li; Stephanie Slania; Nirbhay N Yadav; Jing Liu; Rongfu Wang; Jianhua Zhang; Martin G Pomper; Peter C van Zijl; Xing Yang; Guanshu Liu
Journal:  Chemistry       Date:  2018-01-11       Impact factor: 5.236

4.  Natural D-glucose as a biodegradable MRI relaxation agent.

Authors:  Nirbhay N Yadav; Jiadi Xu; Amnon Bar-Shir; Qin Qin; Kannie W Y Chan; Ksenija Grgac; Wenbo Li; Michael T McMahon; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2014-06-27       Impact factor: 4.668

5.  Detection of in vivo enzyme activity with CatalyCEST MRI.

Authors:  Byunghee Yoo; Vipul R Sheth; Christine M Howison; Matthew J K Douglas; Carlos T Pineda; Erin A Maine; Amanda F Baker; Mark D Pagel
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

6.  The reciprocal linear QUEST analysis method facilitates the measurements of chemical exchange rates with CEST MRI.

Authors:  Edward A Randtke; Liu Qi Chen; Mark D Pagel
Journal:  Contrast Media Mol Imaging       Date:  2014 May-Jun       Impact factor: 3.161

7.  The Hanes-Woolf linear QUESP method improves the measurements of fast chemical exchange rates with CEST MRI.

Authors:  Edward A Randtke; Liu Qi Chen; L Rene Corrales; Mark D Pagel
Journal:  Magn Reson Med       Date:  2013-06-18       Impact factor: 4.668

8.  Characterization of lung cancer by amide proton transfer (APT) imaging: an in-vivo study in an orthotopic mouse model.

Authors:  Osamu Togao; Chase W Kessinger; Gang Huang; Todd C Soesbe; Koji Sagiyama; Ivan Dimitrov; A Dean Sherry; Jinming Gao; Masaya Takahashi
Journal:  PLoS One       Date:  2013-10-15       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.