Optimization of injection dose based on noise-equivalent count rate with use of an anthropomorphic pelvis phantom in three-dimensional 18F-FDG PET/CT.

Kazumasa Inoue1, Hideo Kurosawa, Takashi Tanaka, Masahiro Fukushi, Noriyuki Moriyama, Hirofumi Fujii.   

Abstract

The optimal injection dose for imaging of the pelvic region in 3D FDG PET tests was investigated based on the noise-equivalent count (NEC) rate with use of an anthropomorphic pelvis phantom. Count rates obtained from an anthropomorphic pelvis phantom were compared with those of pelvic images of 60 patients. The correlation between single photon count rates obtained from the pelvic regions of patients and the doses per body weight was also evaluated. The radioactivity at the maximum NEC rate was defined as an optimal injection dose, and the optimal injection dose for the body weight was evaluated. The image noise of a phantom was also investigated. Count rates obtained from an anthropomorphic pelvis phantom corresponded well with those from the human pelvis. The single photon count rate obtained from the phantom was 9.9 Mcps at the peak NEC rate. The coefficient of correlation between the single photon count rate and the dose per weight obtained from patient data was 0.830. The optimal injection doses for a patient with weighing 60 kg were estimated to be 375 MBq (6.25 MBq/kg) and 435 MBq (7.25 MBq/kg) for uptake periods of 60 and 90 min, respectively. The image noise was minimal at the peak NEC rate. We successfully estimated the optimal injection dose based on the NEC rate in the pelvic region on 3D FDG PET tests using an anthropomorphic pelvis phantom.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22207566     DOI: 10.1007/s12194-011-0144-z

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  18 in total

1.  Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes.

Authors:  Osama Mawlawi; Donald A Podoloff; Steve Kohlmyer; John J Williams; Charles W Stearns; Randall F Culp; Homer Macapinlac
Journal:  J Nucl Med       Date:  2004-10       Impact factor: 10.057

Review 2.  Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006.

Authors:  Johannes Czernin; Martin Allen-Auerbach; Heinrich R Schelbert
Journal:  J Nucl Med       Date:  2007-01       Impact factor: 10.057

3.  Impact of target-to-background ratio, target size, emission scan duration, and activity on physical figures of merit for a 3D LSO-based whole body PET/CT scanner.

Authors:  M Brambilla; R Matheoud; C Secco; G Sacchetti; S Comi; M Rudoni; A Carriero; E Inglese
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

4.  Model-based scatter correction for fully 3D PET.

Authors:  J M Ollinger
Journal:  Phys Med Biol       Date:  1996-01       Impact factor: 3.609

5.  Exact and approximate rebinning algorithms for 3-D PET data.

Authors:  M Defrise; P E Kinahan; D W Townsend; C Michel; M Sibomana; D F Newport
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

6.  Capabilities of two- and three-dimensional FDG-PET for detecting small lesions and lymph nodes in the upper torso: a dynamic phantom study.

Authors:  R R Raylman; P V Kison; R L Wahl
Journal:  Eur J Nucl Med       Date:  1999-01

7.  Experimental comparison of lesion detectability for four fully-3D PET reconstruction schemes.

Authors:  Dan J Kadrmas; Michael E Casey; Noel F Black; James J Hamill; Vladimir Y Panin; Maurizio Conti
Journal:  IEEE Trans Med Imaging       Date:  2008-10-03       Impact factor: 10.048

8.  Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera.

Authors:  Hendrik Everaert; Christian Vanhove; Tony Lahoutte; Kristoff Muylle; Vicky Caveliers; Axel Bossuyt; Philippe R Franken
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-23       Impact factor: 9.236

9.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

Authors:  C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-19       Impact factor: 9.236

10.  Objective and subjective comparison of standard 2-D and fully 3-D reconstructed data on a PET/CT system.

Authors:  Klaus Strobel; Matthias Rüdy; Valerie Treyer; Patrick Veit-Haibach; Cyrill Burger; Thomas F Hany
Journal:  Nucl Med Commun       Date:  2007-07       Impact factor: 1.690

View more
  3 in total

Review 1.  Dosage optimization in positron emission tomography: state-of-the-art methods and future prospects.

Authors:  Nicolas A Karakatsanis; Eleni Fokou; Charalampos Tsoumpas
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-10-12

2.  Estimation of activity of administered 18F-fluorodeoxyglucose by measurement of the dose equivalent rate on the right temporal region of the head.

Authors:  Kenta Sakaguchi; Makoto Hosono; Tomomi Imamura; Naomi Takahara; Misa Hayashi; Yuko Yakushiji; Kazunari Ishii; Tatsuro Uto; Takamichi Murakami
Journal:  EJNMMI Phys       Date:  2016-11-14

3.  Patient-specific optimisation of administered activity and acquisition times for 18F-FDG PET imaging.

Authors:  Fred Wickham; Helena McMeekin; Maria Burniston; Daniel McCool; Deborah Pencharz; Annah Skillen; Thomas Wagner
Journal:  EJNMMI Res       Date:  2017-01-13       Impact factor: 3.138

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.