Literature DB >> 22204793

Plating of humeral shaft fractures: comparison of standard conventional plating versus minimally invasive plating.

C-W Oh1, Y-S Byun, J-K Oh, J-J Kim, I-H Jeon, J-H Lee, K-H Park.   

Abstract

PURPOSE: This study compared clinical outcomes and complications in patients with humeral shaft fractures treated using two methods of fixation by plating.
METHODS: Minimally invasive plate osteosynthesis (MIPO, n=29) was prospectively performed from around the middle of the study period, while open reduction and plate osteosynthesis (ORPO, n=30) had been the original standard method. Locking compression plate was used in these two groups. Major characteristics of the two groups were similar in terms of fracture type, fracture location, age, associated injuries and numbers of open fractures.
RESULTS: Primary union was achieved in 28 of 29 in the MIPO and in 27 of 30 in the ORPO. Mean time to union was similar in the two groups. Mean operation time in the MIPO (110min) was shorter than in the ORPO (169min) (P<0.05). Bone grafting was performed in five patients of in the ORPO, but in no patient in the MIPO (P<0.0001). There was one case of deep infection in the ORPO. Functional outcome was satisfactory in both groups.
CONCLUSIONS: Minimally invasive plate osteosynthesis may achieve comparable results with the open plate osteosynthesis method in simple as well as complex fractures of humeral shaft. Although MIPO potentially has the radiation hazard, it may reduce the perioperative complications with a shortened operation time. LEVEL OF EVIDENCE: Level III. Case-control study.
Copyright © 2011 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22204793     DOI: 10.1016/j.otsr.2011.09.016

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  11 in total

1.  Internal fixation of humeral shaft fractures using minimally invasive plating: comparative study of two implants.

Authors:  Longxiang Shen; Hui Qin; Zhiquan An; Bingfang Zeng; Famin Yang
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-07-05

2.   Time until union in absolute vs. relative stability MIPO plating in simple humeral shaft fractures.

Authors:  Ignacio Rellán; Gerardo Luis Gallucci; Agustin Guillermo Donndorff; Pablo De Carli; Ezequiel Ernesto Zaidenberg; Marc Joseph Richard; Jorge Guillermo Boretto
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-29

Review 3.  Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis.

Authors:  Xuqi Hu; Siqi Xu; Huigen Lu; Bao Chen; Xiao Zhou; Xiaojun He; Jiaping Dai; Zhongwei Zhang; Suiliang Gong
Journal:  J Orthop Surg Res       Date:  2016-05-11       Impact factor: 2.359

4.  A Bayesian network meta-analysis of three different surgical procedures for the treatment of humeral shaft fractures.

Authors:  Hao Qiu; Zhihui Wei; Yuting Liu; Jing Dong; Xin Zhou; Liangjun Yin; Minhua Zhang; Minpeng Lu
Journal:  Medicine (Baltimore)       Date:  2016-12       Impact factor: 1.889

5.  Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures.

Authors:  Jae-Jung Jeong; Sang-Eun Park; Hwan-Hee Lee; Jong-Hun Ji; Min-Sik Park; Yong-Taek Park
Journal:  BMC Musculoskelet Disord       Date:  2019-08-17       Impact factor: 2.362

6.  Open reduction and internal fixation of humeral midshaft fractures: anterior versus posterior plate fixation.

Authors:  Sebastian Lotzien; Clemens Hoberg; Valentin Rausch; Thomas Rosteius; Thomas Armin Schildhauer; Jan Gessmann
Journal:  BMC Musculoskelet Disord       Date:  2019-11-10       Impact factor: 2.362

Review 7.  Is Minimally Invasive Plating Osteosynthesis Better Than Conventional Open Plating for Humeral Shaft Fractures? A Systematic Review and Meta-Analysis of Comparative Studies.

Authors:  Kumar Keshav; Anurag Baghel; Vishal Kumar; Deepak Neradi; Kumar Kaustubh; Prabhaker Mishra
Journal:  Indian J Orthop       Date:  2021-05-09       Impact factor: 1.251

8.  Callus Formation and Mineralization after Fracture with Different Fixation Techniques: Minimally Invasive Plate Osteosynthesis versus Open Reduction Internal Fixation.

Authors:  Haitao Xu; Zichao Xue; Haoliang Ding; Hui Qin; Zhiquan An
Journal:  PLoS One       Date:  2015-10-07       Impact factor: 3.240

9.  Treatment of Humeral Shaft Fractures: Minimally Invasive Plate Osteosynthesis Versus Open Reduction and Internal Fixation.

Authors:  Ali Akbar Esmailiejah; Mohammad Reza Abbasian; Farshad Safdari; Keyqobad Ashoori
Journal:  Trauma Mon       Date:  2015-08-01

10.  Comparison of minimally invasive plate osteosynthesis and conventional plate osteosynthesis for humeral shaft fracture: A meta-analysis.

Authors:  Bin-Feng Yu; Liang-le Liu; Guo-Jing Yang; Lei Zhang; Xi-Peng Lin
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.