Literature DB >> 22204117

Challenges associated with using bovine serum in wear testing orthopaedic biopolymers.

A P Harsha1, T J Joyce.   

Abstract

For appropriate in vitro wear testing of prostheses and their biomaterials, the choice of lubricant is critical. Bovine serum is the lubricant recommended by several international standards for wear testing artificial joints and their biomaterials because the wear rate and wear mechanisms closely match clinical results of polyethylene bearings. The main problem with the use of bovine serum as a lubricant is protein degradation and precipitation formation, effects that are recognized as having a direct impact on wear processes. Hence, some researchers have questioned the validity of using bovine serum in simulator testing. This paper reviews the various lubricants used in laboratory wear studies and also the properties of the synovial fluid that the lubricant is trying to replicate. It is clear from the literature survey that the composition of bovine-serum-based lubricants does not match that of synovial fluid. In view of this conclusion, it is suggested that there is a need to develop an alternative lubricant that can replace bovine serum.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22204117     DOI: 10.1177/0954411911416047

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  Fibroblast-like synoviocyte mechanosensitivity to fluid shear is modulated by interleukin-1α.

Authors:  Eben G Estell; Lance A Murphy; Amy M Silverstein; Andrea R Tan; Roshan P Shah; Gerard A Ateshian; Clark T Hung
Journal:  J Biomech       Date:  2017-06-28       Impact factor: 2.712

2.  PEEK-OPTIMA as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study.

Authors:  Raelene M Cowie; Adam Briscoe; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2016-09-27       Impact factor: 1.617

3.  Toward Development of a Diabetic Synovium Culture Model.

Authors:  Neeraj Sakhrani; Andy J Lee; Lance A Murphy; Hagar M Kenawy; Christopher J Visco; Gerard A Ateshian; Roshan P Shah; Clark T Hung
Journal:  Front Bioeng Biotechnol       Date:  2022-02-21

4.  Wear Resistant Nanocomposites Based on Biomedical Grade UHMWPE Paraffin Oil and Carbon Nano-Filler: Preliminary Biocompatibility and Antibacterial Activity Investigation.

Authors:  Michelina Catauro; Cristina Scolaro; Giovanni Dal Poggetto; Severina Pacifico; Annamaria Visco
Journal:  Polymers (Basel)       Date:  2020-04-22       Impact factor: 4.329

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.