A four-dimensional computed tomography analysis of multiorgan abdominal motion.

Joshua L Hallman1, Shinichiro Mori, Gregory C Sharp, Hsiao-Ming Lu, Theodore S Hong, George T Y Chen.   

Abstract

PURPOSE: To characterize and quantify multiorgan respiration-induced motion in the abdomen in liver and pancreatic cancer patients. METHODS AND MATERIALS: Four-dimensional computed tomography scans were acquired for 18 patients treated for abdominal tumors. Contours of multiple abdominal organs were drawn by the radiation oncologist at one respiratory phase; these contours were propagated to other respiratory phases by deformable registration. Three-dimensional organ models were generated from the resulting contours at each phase. Motions of the bounding box and center of mass were extracted and analyzed for the clinical target volume and organs at risk.
RESULTS: On average, the center of mass motion for liver clinical target volumes was 9.7 mm (SD 5 mm) in the superior-inferior direction, with a range of 3 to 18 mm; for pancreatic tumors, the average was 5 mm (SD 1 mm) m with a range of 3 to 7 mm. Abdominal organs move in unison, but with varying amplitudes. Gating near exhale (T40-T60) reduces the range of motion by a factor of ∼10.
CONCLUSION: We have used deformable registration to calculate the trajectories of abdominal organs in four dimensions, based on center of mass and bounding box motion metrics. Our results are compared with previously reported studies. Possible reasons for differences are discussed.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22197238     DOI: 10.1016/j.ijrobp.2011.06.1970

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  24 in total

1.  A 4D ultrasound real-time tracking system for external beam radiotherapy of upper abdominal lesions under breath-hold.

Authors:  Dwi Seno Kuncoro Sihono; Lena Vogel; Christel Weiß; Johannes Thölking; Frederik Wenz; Frank Lohr; Judit Boda-Heggemann; Hansjörg Wertz
Journal:  Strahlenther Onkol       Date:  2016-12-05       Impact factor: 3.621

2.  Segmental analysis of respiratory liver motion in patients with and without a history of abdominal surgery.

Authors:  Yasuhiro Shimizu; Shigeyuki Takamatsu; Kazutaka Yamamoto; Yoshikazu Maeda; Makoto Sasaki; Hiroyasu Tamamura; Sayuri Bou; Tomoyasu Kumano; Toshifumi Gabata
Journal:  Jpn J Radiol       Date:  2018-06-20       Impact factor: 2.374

Review 3.  Motion management in gastrointestinal cancers.

Authors:  Hassan Abbas; Bryan Chang; Zhe Jay Chen
Journal:  J Gastrointest Oncol       Date:  2014-06

Review 4.  Chemoradiation for gastric cancer: controversies, updates and novel techniques.

Authors:  M Fan; W Hu; Z Zhang
Journal:  Br J Radiol       Date:  2015-04-01       Impact factor: 3.039

5.  A single reference measurement can predict liver tumor motion during respiration.

Authors:  Jakub Cvek; Lukas Knybel; Lukas Molenda; Bretislav Otahal; Tomas Jonszta; Daniel Czerny; David Feltl
Journal:  Rep Pract Oncol Radiother       Date:  2015-12-29

6.  Daily CT guidance improves target coverage during definitive radiation therapy for gastric MALT lymphoma.

Authors:  He Wang; Sarah A Milgrom; Bouthaina S Dabaja; Grace L Smith; Mary Martel; Chelsea C Pinnix
Journal:  Pract Radiat Oncol       Date:  2017-03-06

7.  An MRI-compatible platform for one-dimensional motion management studies in MRI.

Authors:  Joris Nofiele; Qing Yuan; Mohammad Kazem; Ken Tatebe; Quinn Torres; Amit Sawant; Ivan Pedrosa; Rajiv Chopra
Journal:  Magn Reson Med       Date:  2015-10-23       Impact factor: 4.668

8.  Individualized 4-dimensional computed tomography proton treatment for pancreatic tumors.

Authors:  Matthew L Knecht; Ning Wang; April Vassantachart; Rachel Mifflin; Jerry D Slater; Gary Y Yang
Journal:  J Gastrointest Oncol       Date:  2017-08

9.  Quantification of Pediatric Abdominal Organ Motion With a 4-Dimensional Magnetic Resonance Imaging Method.

Authors:  Jinsoo Uh; Matthew J Krasin; Yimei Li; Xingyu Li; Christopher Tinkle; John T Lucas; Thomas E Merchant; Chiaho Hua
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-05-25       Impact factor: 8.013

10.  Robust breathing signal extraction from cone beam CT projections based on adaptive and global optimization techniques.

Authors:  Ming Chao; Jie Wei; Tianfang Li; Yading Yuan; Kenneth E Rosenzweig; Yeh-Chi Lo
Journal:  Phys Med Biol       Date:  2016-03-23       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.