Literature DB >> 22196681

A dual centre study of setup accuracy for thoracic patients based on cone-beam CT data.

Tine B Nielsen1, Vibeke N Hansen, Jonas Westberg, Olfred Hansen, Carsten Brink.   

Abstract

BACKGROUND AND
PURPOSE: To compare setup uncertainties at two different institutions by using identical imaging and analysis techniques for thoracic patients with different fixation equipments. METHODS AND MATERIALS: Patient registration results from Cone-Beam CT (CBCT) scans of 174 patients were evaluated (1068 CBCT scans). Patients were fixated using a standard or custom made fixation at Royal Marsden Hospital and Odense University Hospital, respectively. Five imaging protocols were retrospectively simulated to compare the fixation equipments. Systematic and random setup uncertainties were calculated to estimate sufficient treatment margins.
RESULTS: The setup uncertainties are of similar sizes at the two institutions and there is no observable drift in the precision of the fixation equipments during the treatment course. When a correcting imaging protocol is performed there is a significant increase of the systematic setup uncertainties in between imaging fractions. A margin reduction of ≥0.2 cm can be achieved for patients with peak-to-peak respiration amplitudes of ≥1.2 cm when changing from 4D-CT to Active Breathing Coordinator™ (ABC).
CONCLUSIONS: The setup uncertainties at the two institutions are the same despite different fixation equipments. Hence margins cannot be reduced by changing fixating equipment.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22196681     DOI: 10.1016/j.radonc.2011.11.012

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  6 in total

Review 1.  Image-guided radiotherapy and motion management in lung cancer.

Authors:  S S Korreman
Journal:  Br J Radiol       Date:  2015-05-08       Impact factor: 3.039

2.  Toxicity and dosimetric analysis of non-small cell lung cancer patients undergoing radiotherapy with 4DCT and image-guided intensity modulated radiotherapy: a regional centre's experience.

Authors:  Gareth C Livingston; Andrew J Last; Thomas P Shakespeare; Patrick M Dwyer; Justin Westhuyzen; Michael J McKay; Lisa Connors; Stephanie Leader; Stuart Greenham
Journal:  J Med Radiat Sci       Date:  2016-02-15

3.  Efficacy and workload analysis of a fixed vertical couch position technique and a fixed-action-level protocol in whole-breast radiotherapy.

Authors:  Saskia Petillion; Karolien Verhoeven; Caroline Weltens; Frank Van den Heuvel
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

4.  Influence of Clinical and Tumor Factors on Interfraction Setup Errors With Rotation Correction for Vacuum Cushion in Lung Stereotactic Body Radiation Therapy.

Authors:  Hua Chen; Lingxiang Liu; Hao Wang; Yan Shao; Hengle Gu; Yanhua Duan; Aihui Feng; Ying Huang; Zhiyong Xu
Journal:  Front Oncol       Date:  2021-10-21       Impact factor: 6.244

5.  Comparative analysis of thermoplastic masks versus vacuum cushions in stereotactic body radiotherapy.

Authors:  Arturo Navarro-Martin; Jon Cacicedo; Olwen Leaman; Ismael Sancho; Elvira García; Valentin Navarro; Ferran Guedea
Journal:  Radiat Oncol       Date:  2015-08-20       Impact factor: 3.481

6.  Quantifying variability of intrafractional target motion in stereotactic body radiotherapy for lung cancers.

Authors:  Mark K H Chan; Dora L W Kwong; Eric Tam; Anthony Tong; Sherry C Y Ng
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.