Literature DB >> 22178630

Improving the standard of the standard for glass ionomers: an alternative to the compressive fracture strength test for consideration?

Adam H Dowling1, Garry J P Fleming, Emma L McGinley, Owen Addison.   

Abstract

OBJECTIVES: Three strength tests (compressive, three point flexure and biaxial) were performed on three glass ionomer (GI) restoratives to assess the most appropriate methodology in terms of validity and reliability. The influence of mixing induced variability on the data sets generated were eliminated by using encapsulated GIs.
METHODS: Specimen groups of 40 (eight batches of n=5) cylinders (6.0±0.1mm height, 4.0±0.1mm diameter) for compressive fracture testing, bars (25.0±0.1mm length, 2.0±0.1mm height, 2.0±0.1mm width) for three point flexure testing and discs (13.0±0.1mm diameter, 1.0±0.1mm thickness) for biaxial flexure testing were randomly prepared by an operator. The strength data sets for each GI restorative were pooled and one-way analyses of variance (ANOVAs) were conducted to compare between GI restoratives (p=0.05). The coefficient of variation (CoV) values for each test were pooled and a one-way ANOVA was conducted to test for differences between the reliability of the three tests.
RESULTS: For the GI restoratives, the one-way ANOVA showed significant differences when tested in compression (p=0.001) but not when tested in three point (p=0.271) or biaxial (p=0.134) flexure. The pooled CoV values showed no significant difference between the three strength tests (p=0.632).
CONCLUSIONS: The compressive fracture strength test specified for GIs in the International Organisation for Standardisation (ISO 9917-1: 2003) should be replaced and should no longer be advocated for the predictive performance modelling of GI restoratives. Copyright Â
© 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22178630     DOI: 10.1016/j.jdent.2011.12.002

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  4 in total

1.  Effect of a calcium chloride solution treatment on physical and mechanical properties of glass ionomer cements.

Authors:  Dimitrios Dionysopoulos; Kosmas Tolidis; Dimitrios Tortopidis; Paris Gerasimou; Thrasyvoulos Sfeikos
Journal:  Odontology       Date:  2018-01-22       Impact factor: 2.634

2.  How mobile are protons in the structure of dental glass ionomer cements?

Authors:  Ana R Benetti; Johan Jacobsen; Benedict Lehnhoff; Niels C R Momsen; Denis V Okhrimenko; Mark T F Telling; Nikolay Kardjilov; Markus Strobl; Tilo Seydel; Ingo Manke; Heloisa N Bordallo
Journal:  Sci Rep       Date:  2015-03-10       Impact factor: 4.379

3.  Biaxial flexural strength of high-viscosity glass-ionomer cements heat-cured with an LED lamp during setting.

Authors:  Gustavo Fabián Molina; Ricardo Juan Cabral; Ignacio Mazzola; Laura Brain Lascano; Jo E Frencken
Journal:  Biomed Res Int       Date:  2013-06-12       Impact factor: 3.411

4.  Effect of discontinuous glass fibers on mechanical properties of glass ionomer cement.

Authors:  Sufyan K Garoushi; Jingwei He; Pekka K Vallittu; Lippo V J Lassila
Journal:  Acta Biomater Odontol Scand       Date:  2018-07-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.