Literature DB >> 17154708

Protection filter-related events in extracranial carotid artery stenting: a single-center experience.

Bae Ju Kwon1, Moon Hee Han, Hyun-Seung Kang, Cheolkyu Jung.   

Abstract

PURPOSE: To report the complications, rescue procedures, and consequences related to the use of an embolus protection filter during carotid artery stenting (CAS).
METHODS: A retrospective review was undertaken of 72 patients (58 men; mean age 70.0+/-8.2 years, range 56-87) with extracranial atherosclerotic carotid stenosis who underwent 77 CAS procedures under filter protection. Filter-related events and rescue procedures according to each procedural step were retrospectively evaluated on CAS angiograms. In addition, neurological events and outcomes were also assessed.
RESULTS: CAS using a filter was successful in 99% of cases, and the overall rate of minor stroke (n=1), major stroke (0), or mortality (n=1) was 2.6% at 30 days. Filter placement was successful in all cases. However, arterial tortuosity made it difficult for a filter to pass through the stenosis in 1 case; this was overcome with an additional supportive wire (0.018-inch). Filter-related events were flow impairment in 6 (7.8%), filter wedging in the catheter tip in 4 (5.2%), vasospasm >50% narrowing in 7 (9.1%), filling defects within the filter membrane in 5 (6.5%), retrieval failure with the provided retriever in 3 (3.9%), and insecure retrieval without filter collapse in 2 (2.6%). Flow impairment caused drowsy mentality and impaired verbal response in 4, which resolved after prompt filter retrieval. All the cases of filter wedging were resolved with a catheter pulled down into the stented segment to separate the filter element from the catheter tip. Significant vasospasm and filling defects were spontaneously resolved in all cases after filter retrieval. Inability to pass a retriever catheter through a stent was overcome with curved 5-F catheter manipulation in all 3 cases.
CONCLUSION: The use of a filter during CAS may induce various angiographic or technical events at each step. For a severely stenotic and tortuous carotid lesion with difficult access, a filter may become trapped or irretrievable during flow arrest. Physicians should be aware of the preventive and rescue maneuvers to counter filter-related events, perhaps even considering another type of protection mechanism or carotid endarterectomy.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17154708     DOI: 10.1583/06-1900.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  9 in total

1.  Efficacy of Rho kinase inhibitor on cognitive impairment induced by chronic cerebral hypoperfusion in rats.

Authors:  Qiang Zhang; Jun-Jian Zhang; Zhong-Mou Han
Journal:  Int J Clin Exp Med       Date:  2015-02-15

2.  Carotid baroreceptor reaction after stenting in 2 locations of carotid bulb lesions of different embryologic origin.

Authors:  D C Suh; J L Kim; E H Kim; J K Kim; J-H Shin; D H Hyun; H Y Lee; D H Lee; J S Kim
Journal:  AJNR Am J Neuroradiol       Date:  2012-01-19       Impact factor: 3.825

3.  Initial experience of carotid artery stenting using the Carotid WALLSTENT and FilterWire EZ in Japan.

Authors:  Katsutoshi Takayama; Toshiaki Taoka; Hiroyuki Nakagawa; Kaoru Myouchin; Takeshi Wada; Toshiteru Miyasaka; Masahiko Sakamoto; Akio Fukusumi; Satoru Iwasaki; Ryota Kimura; Shinichiro Kurokawa; Kimihiko Kichikawa
Journal:  Jpn J Radiol       Date:  2011-01-26       Impact factor: 2.374

Review 4.  Management of extracranial carotid artery disease.

Authors:  Yinn Cher Ooi; Nestor R Gonzalez
Journal:  Cardiol Clin       Date:  2015-02       Impact factor: 2.213

5.  Clinical implications of internal carotid artery flow impairment caused by filter occlusion during carotid artery stenting.

Authors:  O-K Kwon; S H Kim; E A Jacobsen; M P Marks
Journal:  AJNR Am J Neuroradiol       Date:  2011-12-15       Impact factor: 3.825

6.  Initial experience of using the filter protection device during carotid artery stenting in Japan.

Authors:  Katsutoshi Takayama; Hiroyuki Nakagawa; Satoru Iwasaki; Toshiaki Taoka; Toshiteru Miyasaka; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Ichiro Nakagawa; Shinichiro Kurokawa; Kimihiko Kichikawa
Journal:  Radiat Med       Date:  2008-08-03

7.  Treatment outcomes of carotid artery stenting with two types of distal protection filter device.

Authors:  Minoru Iko; Hiroshi Aikawa; Yoshinori Go; Kanji Nakai; Masanori Tsutsumi; Iwae Yu; Taichiro Mizokami; Kimiya Sakamoto; Ritsuro Inoue; Takafumi Mitsutake; Ayumu Eto; Hayatsura Hanada; Kiyoshi Kazekawa
Journal:  Springerplus       Date:  2014-03-08

Review 8.  Selective-versus-Standard Poststent Dilation for Carotid Artery Disease: A Systematic Review and Meta-Analysis.

Authors:  O Petr; W Brinjikji; M H Murad; B Glodny; G Lanzino
Journal:  AJNR Am J Neuroradiol       Date:  2017-03-16       Impact factor: 3.825

9.  Comparison of Flow Impairment during Carotid Artery Stenting Using Two Types of Eccentric Filter Embolic Protection Devices.

Authors:  Kouhei Nii; Masanori Tsutsumi; Hitoshi Maeda; Hiroshi Aikawa; Ritsuro Inoue; Ayumu Eto; Kimiya Sakamoto; Takafumi Mitsutake; Hayatsura Hanada; Kiyoshi Kazekawa
Journal:  Neurol Med Chir (Tokyo)       Date:  2016-06-16       Impact factor: 1.742

  9 in total