Literature DB >> 22173609

Changed cervical kinematics after fusion surgery.

E Cattrysse1, M Moens, E Schaillée, J D'Haens, P Van Roy.   

Abstract

PURPOSE: Analyzing and comparing the range of motion and movement pattern of subjects who underwent an anterior cervical fusion using trabecular metal with control subjects.
METHODS: Three-dimensional kinematics of planar active axial rotation and active lateral bending of 50 experimental and 41 control subjects were registered by means of an electromagnetic tracking system.
RESULTS: Comparing the experimental group with the control group reveals that the range of the main motion component differs significantly (p < 0.01) during the active axial rotation and lateral bending movement. During active axial rotation, the coupled lateral bending motion component also differs between both groups. The root mean square value of the jerkiness (derivative of the acceleration) and de deviation from the 6-polynomial smoothed function of the main as well as the coupled motion component express the qualitative aspects of kinematics and are significantly different between the experimental and the control group for both movements (p < 0.05).
CONCLUSIONS: Subjects who have an anterior cervical fusion with trabecular metal show significant quantitative as well as qualitative differences in cervical kinematics during active axial rotation and lateral bending compared to control subjects.

Entities:  

Mesh:

Year:  2011        PMID: 22173609      PMCID: PMC3389115          DOI: 10.1007/s00586-011-2112-z

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  13 in total

1.  Normal global motion of the cervical spine: an electrogoniometric study.

Authors:  V Feipel; B Rondelet; J Le Pallec; M Rooze
Journal:  Clin Biomech (Bristol, Avon)       Date:  1999-08       Impact factor: 2.063

2.  The use of disharmonic motion curves in problems of the cervical spine.

Authors:  V Feipel; B Rondelet; J P LePallec; O DeWitte; M Rooze
Journal:  Int Orthop       Date:  1999       Impact factor: 3.075

3.  Three-dimensional analysis of active cervical motion: the effect of age and gender.

Authors:  P H Trott; M J Pearcy; S A Ruston; I Fulton; C Brien
Journal:  Clin Biomech (Bristol, Avon)       Date:  1996-06       Impact factor: 2.063

4.  Influence of cranio-cervical posture on three-dimensional motion of the cervical spine.

Authors:  Stephen J Edmondston; Svein-Erik Henne; Winston Loh; Eirik Ostvold
Journal:  Man Ther       Date:  2005-02

Review 5.  Cervical total disc replacement, part I: rationale, biomechanics, and implant types.

Authors:  Mahidhar M Durbhakula; Gary Ghiselli
Journal:  Orthop Clin North Am       Date:  2005-07       Impact factor: 2.472

6.  Interobserver reliability of neck-mobility measurement by means of the flock-of-birds electromagnetic tracking system.

Authors:  Nienke Assink; Gert J D Bergman; Bianca Knoester; Jan C Winters; Pieter U Dijkstra; Klaas Postema
Journal:  J Manipulative Physiol Ther       Date:  2005 Jul-Aug       Impact factor: 1.437

7.  Sensorimotor disturbances in chronic neck pain--range of motion, peak velocity, smoothness of movement, and repositioning acuity.

Authors:  Per Sjölander; Peter Michaelson; Slobodan Jaric; Mats Djupsjöbacka
Journal:  Man Ther       Date:  2007-01-02

8.  Kinematic analysis of the cervical spine following implantation of an artificial cervical disc.

Authors:  Gwynedd E Pickett; Jeffrey P Rouleau; Neil Duggal
Journal:  Spine (Phila Pa 1976)       Date:  2005-09-01       Impact factor: 3.468

9.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference.

Authors:  A D Milne; D G Chess; J A Johnson; G J King
Journal:  J Biomech       Date:  1996-06       Impact factor: 2.712

10.  Spinal motion after cervical fusion. In vivo assessment with roentgen stereophotogrammetry.

Authors:  S Lee; K G Harris; V K Goel; C R Clark
Journal:  Spine (Phila Pa 1976)       Date:  1994-10-15       Impact factor: 3.468

View more
  1 in total

1.  Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion.

Authors:  Zhongyang Gao; Hui Song; Fenggang Ren; Yuhuan Li; Dong Wang; Xijing He
Journal:  Exp Ther Med       Date:  2017-09-29       Impact factor: 2.447

  1 in total