Literature DB >> 22169230

Agreement and reading time for differently-priced devices for the digital capture of X-ray films.

Antonio José Salazar1, Juan Camilo Camacho, Diego Andrés Aguirre.   

Abstract

We assessed the reliability of three digital capture devices: a film digitizer (which cost US $15,000), a flat-bed scanner (US $1800) and a digital camera (US $450). Reliability was measured as the agreement between six observers when reading images acquired from a single device and also in terms of the pair-device agreement. The images were 136 chest X-ray cases. The variables measured were the interstitial opacities distribution, interstitial patterns, nodule size and percentage pneumothorax size. The agreement between the six readers when reading images acquired from a single device was similar for the three devices. The pair-device agreements were moderate for all variables. There were significant differences in reading-time between devices: the mean reading-time for the film digitizer was 93 s, it was 59 s for the flat-bed scanner and 70 s for the digital camera. Despite the differences in their cost, there were no substantial differences in the performance of the three devices.

Entities:  

Mesh:

Year:  2011        PMID: 22169230     DOI: 10.1258/jtt.2011.110708

Source DB:  PubMed          Journal:  J Telemed Telecare        ISSN: 1357-633X            Impact factor:   6.184


  4 in total

1.  Evaluation of three pneumothorax size quantification methods on digitized chest X-ray films using medical-grade grayscale and consumer-grade color displays.

Authors:  Antonio J Salazar; Diego A Aguirre; Juliana Ocampo; Juan C Camacho; Xavier A Díaz
Journal:  J Digit Imaging       Date:  2014-04       Impact factor: 4.056

2.  Evaluation of low-cost telemammography screening configurations: a comparison with film-screen readings in vulnerable areas.

Authors:  Antonio J Salazar; Javier Romero; Oscar Bernal; Angela Moreno; Sofía Velasco; Xavier Díaz
Journal:  J Digit Imaging       Date:  2014-10       Impact factor: 4.056

3.  Noninferiority and Equivalence Evaluation of Clinical Performance among Computed Radiography, Film, and Digitized Film for Telemammography Services.

Authors:  Antonio J Salazar; Javier A Romero; Oscar A Bernal; Angela P Moreno; Sofía C Velasco; Xavier A Díaz
Journal:  Int J Telemed Appl       Date:  2016-09-29

4.  A recommended method in order to interpret chest x-rays for diagnosing small size pneumothorax.

Authors:  Mohammad-Reza Ghane; Amin Saburi; Hamid-Reza Javadzadeh
Journal:  Int J Crit Illn Inj Sci       Date:  2013-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.