Literature DB >> 22169134

Inter-electrode spacing of surface EMG sensors: reduction of crosstalk contamination during voluntary contractions.

Carlo J De Luca1, Mikhail Kuznetsov, L Donald Gilmore, Serge H Roy.   

Abstract

We investigated the influence of inter-electrode spacing on the degree of crosstalk contamination in surface electromyographic (sEMG) signals in the tibialis anterior (target muscle), generated by the triceps surae (crosstalk muscle), using bar and disk electrode arrays. The degree of crosstalk contamination was assessed for voluntary constant-force isometric contractions and for dynamic contractions during walking. Single-differential signals were acquired with inter-electrode spacing ranging from 5 mm to 40 mm. Additionally, double differential signals were acquired at 10 mm spacing using the bar electrode array. Crosstalk contamination at the target muscle was expressed as the ratio of the detected crosstalk signal to that of the target muscle signal. The crosstalk contamination ratio approached a mean of 50% for the 40 mm spacing for triceps surae muscle contractions at 80% MVC and tibialis anterior muscle contractions at 10% MVC. For single differential recordings, the minimum crosstalk contamination was obtained from the 10 mm spacing. The results showed no significant differences between the bar and disk electrode arrays. During walking, the crosstalk contamination on the tibialis anterior muscle reached levels of 23% for a commonly used 22 mm spacing single-differential disk sensor, 17% for a 10 mm spacing single-differential bar sensor, and 8% for a 10 mm double-differential bar sensor. For both studies the effect of electrode spacing on crosstalk contamination was statistically significant. Crosstalk contamination and inter-electrode spacing should therefore be a serious concern in gait studies when the sEMG signal is collected with single differential sensors. The contamination can distort the target muscle signal and mislead the interpretation of its activation timing and force magnitude.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2011        PMID: 22169134     DOI: 10.1016/j.jbiomech.2011.11.010

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  34 in total

1.  Spatial variation of compound muscle action potentials across human gastrocnemius medialis.

Authors:  Taian M Vieira; Alberto Botter; Marco A Minetto; Emma F Hodson-Tole
Journal:  J Neurophysiol       Date:  2015-07-08       Impact factor: 2.714

2.  Recording and assessment of evoked potentials with electrode arrays.

Authors:  N Miljković; N Malešević; V Kojić; G Bijelić; T Keller; D B Popović
Journal:  Med Biol Eng Comput       Date:  2015-04-12       Impact factor: 2.602

3.  Badminton players show a lower coactivation and higher beta band intermuscular interactions of ankle antagonist muscles during isokinetic exercise.

Authors:  Lejun Wang; Wenxin Niu; Kuan Wang; Shengnian Zhang; Li Li; Tianfeng Lu
Journal:  Med Biol Eng Comput       Date:  2019-08-31       Impact factor: 2.602

4.  Acquisition of Surface EMG Using Flexible and Low-Profile Electrodes for Lower Extremity Neuroprosthetic Control.

Authors:  Seong Ho Yeon; Tony Shu; Hyungeun Song; Tsung-Han Hsieh; Junqing Qiao; Emily A Rogers; Samantha Gutierrez-Arango; Erica Israel; Lisa E Freed; Hugh M Herr
Journal:  IEEE Trans Med Robot Bionics       Date:  2021-07-21

5.  Functional mapping of the pelvic floor and sphincter muscles from high-density surface EMG recordings.

Authors:  Yun Peng; Jinbao He; Rose Khavari; Timothy B Boone; Yingchun Zhang
Journal:  Int Urogynecol J       Date:  2016-05-18       Impact factor: 2.894

6.  The effectiveness of electromyographic biofeedback as part of a meniscal repair rehabilitation programme.

Authors:  Mihaela Oravitan; Claudiu Avram
Journal:  J Sports Sci Med       Date:  2013-09-01       Impact factor: 2.988

7.  Surface Electromyography-Based Recognition, Synthesis, and Perception of Prosodic Subvocal Speech.

Authors:  Jennifer M Vojtech; Michael D Chan; Bhawna Shiwani; Serge H Roy; James T Heaton; Geoffrey S Meltzner; Paola Contessa; Gianluca De Luca; Rupal Patel; Joshua C Kline
Journal:  J Speech Lang Hear Res       Date:  2021-05-12       Impact factor: 2.297

8.  The Application of Double Elastic Band Exercise in the 90/90 Arm Position for Overhead Athletes.

Authors:  Masaaki Tsuruike; Todd S Ellenbecker; Connor Lauffenburger
Journal:  Sports Health       Date:  2020-07-28       Impact factor: 3.843

Review 9.  Surface electromyography in animal biomechanics: A systematic review.

Authors:  Stephanie Valentin; Rebeka R Zsoldos
Journal:  J Electromyogr Kinesiol       Date:  2015-12-21       Impact factor: 2.368

10.  Electromyography activity of the teres minor muscle with varying positions of horizontal abduction in the quadruped position.

Authors:  Masaaki Tsuruike; Todd S Ellenbecker; Connor Lauffenburger
Journal:  JSES Int       Date:  2021-02-22
View more